Abdominocentesis and intra-abdominal pressure measurement in small animals

George G. Munguia College of Veterinary Medicine, Purdue University, West Lafayette, IN

Search for other papers by George G. Munguia in
Current site
Google Scholar
PubMed
Close
 DVM
and
Elizabeth Thomovsky College of Veterinary Medicine, Purdue University, West Lafayette, IN

Search for other papers by Elizabeth Thomovsky in
Current site
Google Scholar
PubMed
Close
 DVM, MS, DACVECC

Abstract

OBJECTIVE

To provide a video tutorial detailing how to perform “blind” and ultrasound-guided abdominocentesis for diagnostic and therapeutic guidance, and to provide a brief demonstration of intra-abdominal pressure measurement (IAP).

ANIMALS

Any cat or dog with suspicion of free abdominal effusion or patients requiring measurement of IAP.

METHODS

Abdominocentesis should be performed when there is high suspicion for peritoneal effusion based on physical exam and/or diagnostic imaging. The 4-quadrant tap uses 20-gauge or larger needles placed blindly in ≥ 1 of the 4 quadrants of the abdomen to collect abdominal fluid. In contrast, ultrasound allows visualization of fluid in the abdomen prior to percutaneous insertion of a needle and syringe to collect fluid. Regardless of collection technique, fluid should have immediate cytologic analysis and later can be submitted for biochemical parameters, additional cellular analysis by a pathologist, and culture and sensitivity (in rare cases if indicated). Intravesicular bladder pressure measurement using a manometer–urinary catheter system approximates the IAP when there is concern for organ hypoperfusion and compartment syndrome.

RESULTS

Abdominocentesis can be performed with and without the use of ultrasound guidance. Intravesicular bladder pressure measurement is used to diagnose and trend IAP values before and after treatments are performed.

CLINICAL RELEVANCE

Abdominocentesis is a simple and safe technique that all small animal clinicians should be comfortable performing. Effusion sampling can guide further diagnostics and treatments. Measurement of IAP is simple and requires no specialized equipment.

Abstract

OBJECTIVE

To provide a video tutorial detailing how to perform “blind” and ultrasound-guided abdominocentesis for diagnostic and therapeutic guidance, and to provide a brief demonstration of intra-abdominal pressure measurement (IAP).

ANIMALS

Any cat or dog with suspicion of free abdominal effusion or patients requiring measurement of IAP.

METHODS

Abdominocentesis should be performed when there is high suspicion for peritoneal effusion based on physical exam and/or diagnostic imaging. The 4-quadrant tap uses 20-gauge or larger needles placed blindly in ≥ 1 of the 4 quadrants of the abdomen to collect abdominal fluid. In contrast, ultrasound allows visualization of fluid in the abdomen prior to percutaneous insertion of a needle and syringe to collect fluid. Regardless of collection technique, fluid should have immediate cytologic analysis and later can be submitted for biochemical parameters, additional cellular analysis by a pathologist, and culture and sensitivity (in rare cases if indicated). Intravesicular bladder pressure measurement using a manometer–urinary catheter system approximates the IAP when there is concern for organ hypoperfusion and compartment syndrome.

RESULTS

Abdominocentesis can be performed with and without the use of ultrasound guidance. Intravesicular bladder pressure measurement is used to diagnose and trend IAP values before and after treatments are performed.

CLINICAL RELEVANCE

Abdominocentesis is a simple and safe technique that all small animal clinicians should be comfortable performing. Effusion sampling can guide further diagnostics and treatments. Measurement of IAP is simple and requires no specialized equipment.

Acknowledgments

The authors acknowledge Brett Creech for preparation of the video.

Disclosures

Dr. Thomovsky is a member of the JAVMA Scientific Review Board, but was not involved in the editorial evaluation of or decision to accept this video for publication.

No AI-assisted technologies were used in the generation of this video or abstract.

Funding

The authors have nothing to disclose.

Supplementary Materials

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 51637 51637 7507
PDF Downloads 1192 1192 140
Advertisement