Ultrasonography is a noninvasive imaging tool that can be used to assess the size, shape, parenchymal texture, and vascularity of various organs. However, a US image provides low contrast because of the similar acoustic impedances of soft tissues.1 The accuracy of diagnostic US can be improved by IV injection of gas microbubbles as vascular contrast agents.2,3
Ultrasonographic contrast agents consist of tiny, gas-filled microspheres stabilized by an outer shell. These microbubbles (1 to 7 μm in diameter) are smaller than RBCs, eliminating the risk of capillary embolization. Unlike the contrast agents used in CT and MRI, USCAs are confined to the intravascular space, which means that after injection, they remain in the blood pool and do not diffuse into the extracellular space.4,5 The gas content is gradually eliminated from the blood through the lungs, whereas the stabilizing components are filtered by the kidneys and eliminated by the liver.6
The acoustic behavior of microbubbles in a US beam is complex, and contrast-specific imaging techniques are required to achieve clinically useful enhancement. With these techniques, USCAs increase the intensity of the echo signal in gray-scale harmonic and Doppler modes by 10 to 30 dB (10 to 1,000 times) during a mean of 5 minutes, depending on the contrast agent used.7–10 Total duration of a US evaluation with contrast agent is about 20 minutes, and general anesthesia is not required.
Contrast-enhanced US improves the detection of perfusion and vascularity of organs. Lesions that are perfused differently from healthy tissues will be differentially enhanced after USCA administration. For example, regions with segmental infarction will be indicated by a so-called signal void representing the lack of a vascular supply, whereas regions with high vascularization such as malignant tumors will appear as hyperechoic areas.6,11,12 These features also allow differentiation of malignant and benign tumors in some situations.13 Ultrasonographic contrast agents can also be used as blood-pool tracers (functional imaging), in an approach similar to that for scintigraphic tracers, by use of time-intensity curves.6,14
During the last decade, several USCAs have been developed. In the United States, only 3 USCAs are available and approved by the FDA6,15,16 (Table 1).
Characteristics of FDA-approved USCAs in the United States.
Characteristic | Perfutren protein-type A | Perfutren lipid microspheres | Perfexane lipid microspheres | |
---|---|---|---|---|
Commercial name | Optison | Imagent | Defnity | |
Manufacturer | Amersham Health, Princeton, NJ | Alliance Pharmaceutical, San Diego, Calif | Bristol-Myers Squibb, North Billerica, Mass | |
Shell | Human denatured albumin | Surfactant | Phospholipid | |
Gas | Perfuoropropane | Perfuorohexane and air | Octafuoropropane | |
Microbubble count | 6.3 × 108 to 9.0 × 108 bubbles/mL | 1.4 × 109 bubbles/mL | 1.2 × 1010 bubbles/mL | |
Microbubble size | Mean diameter, 3.6–5.4 μm | 99.8% < 10 μm | 98% < 10 μm | |
Preparation | Hand agitation | Reconstitute with 10 mL of isotonic saline (0.9% NaCl) solution | Activation through agitation | |
Vial volume | 3 mL | 10 mL | 2 mL | |
Indications | Echocardiography | Echocardiography | Echocardiography and CHUS, liver and kidney |
The purpose of this literature review was to briefly characterize the imaging techniques needed to perform a CEUS evaluation, provide veterinary practitioners with an overview of indications for CEUS as an alternative to other diagnostic methods, compare characteristics of CEUS with those of other diagnostic modalities, review some potential limiting factors for the use of USCA, and report future possibilities for CEUS. In all studies involving CEUS that are discussed herein, CHUS was used as a contrast-specific imaging technique unless otherwise mentioned.
Contrast-Specific Imaging Techniques
Fundamental B-mode, gray-scale imaging results in poor detectability of USCA in the presence of tissue; thus, it cannot be used for CEUS examinations.10 All Doppler modalities are sensitive to the presence of microbubbles, but this excessive sensitivity results in color blooming (color Doppler) or flash (power Doppler) artifacts because of strong Doppler signals caused by moving tissue, which decreases the usefulness of these modalities.6,17
Consequently, contrast-specific techniques are required to achieve clinically useful enhancement and decrease the frequency of artifacts. Several techniques have been developed such as second harmonic imaging (used in CHUS), pulse-inversion harmonic imaging, cadence-contrast pulse sequencing, and power (amplitude) modulation.17–19 On the basis of these techniques, each ultrasound machine company has developed its own contrast-specific technology.
Each one of the aforementioned contrast-specific techniques exploits the nonlinear acoustic properties of USCAs caused by asymmetric oscillations of the microbubbles within a US beam. This phenomenon results in returning echoes not only at the fundamental frequency (f0), but also at multiples of this frequency (ie, harmonics; eg, 2f0, 3f0, and 4f0). In CHUS, sound is transmitted at the fundamental frequency f0 and the returning echoes are filtered at the second harmonic 2f0 (highest intensity of the harmonics).20 The second harmonic component is therefore separated from the fundamental component.6,10 The nonlinear response from USCAs favors the detection of contrast agents in body tissues and, hence, increases the contrast-to-tissue ratio.10,18,21 Compared with fundamental B-mode image, second harmonic images have a decreased intensity but less artifacts and noise.
Contrast-enhanced harmonic US is available in grayscale and Doppler modalities. In combination with Doppler techniques, it is one of the most sensitive techniques available in terms of contrast-to-tissue ratio.10,19 In combination with second harmonic imaging, the flash artifact can be reduced. Harmonic power Doppler imaging is therefore an effective tool for the detection of flow in small vessels.10
Conditions in Which CEUS is Warranted
In veterinary medicine, there are only a few reports of studies in which CEUS was performed. Ultrasonographic contrast agents were mainly used to evaluate the liver22–25,a and spleen26,b,c in clinically normal and diseased dogs. Furthermore, CEUS has reportedly been used clinically to evaluate the kidneys,22,27,28 pancreas,d,e lymph nodes,29 and naturally developing tumors30 and to visualize portosystemic shunts in dogs.31
Examination of the liver—Examination of focal liver lesions is the main indication of CEUS in dogs and cats. The evaluation of focal lesions with conventional, unenhanced US is based on the gray-scale morphology (analysis of differences in echogenicity from the surrounding healthy liver tissue) and Doppler information regarding macrovascular flow (hypervascularization or hypovascularization).32–34 It facilitates unambiguous diagnosis of liver cysts (anechogenic content) or calcifications (presence of an acoustic shadow) but not always soft tissue liver lesions.33
Liver nodules are common in dogs. In fact, focal hyperplastic nodules have been detected in up to 70% of dogs > 6 years of age and in all dogs > 14 years of age.35 Other causes of liver nodules are hematomas, abscesses, focal hepatic necrotic areas, primary neoplastic lesions (hepatocellular carcinoma, cholangiocellular carcinoma, carcinoid, or sarcoma), and metastases of other primary tumors (hemangiosarcoma, islet cell carcinoma, pancreatic carcinoma, or fibrosarcoma).23,36,37 Ultrasonographic evaluation of liver masses involves 2 essential elements: lesion detection (assessing presence and amount of lesions) and lesion characterization (assessing US characteristics, size, and location of lesions). Once a lesion has been detected, lesion characterization can be helpful in differentiating between tumoral and nontumoral masses, between benign and malignant masses, or even among various malignant processes, with an accuracy superior to that obtained via cytology, the accuracy of which is reportedly 29% to 30.3% in dogs and 51.2% in cats.5,34,38–42
The CEUS pattern in healthy canine liver has been described. As a result of the dual blood supply of liver tissue by the hepatic artery (20% to 30% of blood supply) and the portal vein (70% to 80% of blood supply), 3 subsequent vascular phases are detectable33,34,43,44 (Figure 1). The arterial phase (ie, enhancement of the hepatic artery and its tributaries) usually starts at 7 to 10 seconds following injection of contrast agent and persists for approximately 10 to 15 seconds.a This is followed by the portal-venous phase (ie, enhancement of portal veins) that can start approximately 30 to 45 seconds after injection, persists for 2 minutes after injection, and reveals a blood flow peak after 15 to 60 seconds.23,45,a The delayed phase (ie, enhancement of sinusoids throughout the liver parenchyma) persists until the USCA is no longer detectable in the hepatic parenchyma, which may take 4 to 20 minutes, depending upon the USCA used.34,40,43,44,46
Ultrasonographic images of consecutive vascular enhancement phases in healthy canine liver, as detected via CEUS (contrast-tuned imaging mode). A—During the arterial phase, which can begin 7 to 8 seconds after contrast agent administration in dogs, there is enhancement of the hepatic artery and its small branches (arrows). B—During the portal-venous phase at 35 seconds, there is enhancement of the portal-venous system (open arrows) with already a small amount of contrast agent within the hepatic sinusoids (asterisk). C—During the delayed phase, starting at 45 to 60 seconds, there is homogenous enhancement of the liver attributable to contrast agent within the sinusoids. G = Gallbladder.
Citation: Journal of the American Veterinary Medical Association 234, 4; 10.2460/javma.234.4.460
Lesion detection—Contrast-enhanced US is useful for detecting small and ill-defined malignant lesions or isoechoic lesions, which are often invisible via conventional US.5,15,25,47,48 Compared with conventional US, CEUS can detect additional lesions in 40% to 45% of human patients.38 The technique is particularly superior with respect to detection of metastases because such processes may be associated with little or no contrast agent enhancement15,23,33,34,43 (hypoechogenic defects or signal voids; Figure 2). This superiority was evident in a study25 of 3 dogs with splenic hemangiosarcoma, in which hepatic lesions did not appear in conventional US images but did appear as clearly defined nodules in CEUS images. Most hepatocellular carcinomas appear similarly as metastases in delayed-phase imaging (Figure 3); however, some more highly differentiated tumors are isoechoic, compared with the adjacent liver, which makes their detection far more difficult.15,34
Ultrasonographic images of liver metastases in a dog with pancreatic adenocarcinoma. A—Conventional US of the liver reveals multiple, bluntly outlined hypoechoic lesions (black arrows) and so-called target lesions (nodules with a hypoechoic rim surrounding an isoechoic center; white arrows). B—Late phase of a CEUS evaluation (contrast-tuned imaging mode) reveals clearly defined hypoechoic lesions or so-called signal voids indicative of a neoplastic process.
Citation: Journal of the American Veterinary Medical Association 234, 4; 10.2460/javma.234.4.460
Ultrasonographic images of typical so-called early wash-in, early washout enhancement of the subsequent vascular enhancement phases in a 9-year-old Labrador Retriever with hepatocellular carcinoma. A—Conventional US reveals a large, clearly defined, round heterogenous mass (arrows) surrounded by a small rim of healthy homogenous liver tissue (asterisks). B—During the early arterial phase of CEUS (contrast-tuned imaging mode), the feeding arteries (arrows) of the malignant mass are highlighted by contrast agent. The contrast agent has not yet reached the healthy liver, which is homogenously hypoechoic (asterisks). C—The subsequent portal-venous phase reveals earlier enhancement of the mass (arrows) than that of the surrounding healthy liver parenchyma (asterisks). D—The opposite occurs during late phase of enhancement, in which the decrease in enhancement of the mass (arrows) precedes the surrounding liver parenchyma (asterisk). These features are characteristic of a neoplastic process.
Citation: Journal of the American Veterinary Medical Association 234, 4; 10.2460/javma.234.4.460
Lesion characterization—The changes in enhancement throughout the various aforementioned vascular phases contribute to diagnosis of liver lesions.15,43,49 The arterial phase provides information on degree and pattern of vascularity, whereas the portal-venous and delayed phases provide information about the clearing of USCA from the lesion, compared with normal liver tissue.13,34,43 Most benign liver lesions appear to have typical sustained enhancement (Figure 4). This means that a lesion is enhanced to a greater degree than the liver during the arterial phase and continues to be enhanced to a degree equal to or greater than that of the liver during the portal-venous phase. Thus, benign liver lesions can be differentiated from most malignant lesions, which have early arterial phase enhancement greater than that of the liver and portal-venous and delayed phase enhancement less than that of the liver (so-called early wash-in, early washout phenomenon; Figures 2 and 3). This happens because malignant liver tumors, whether primary or secondary, obtain most of their blood supply from the hepatic artery.15,34,43,50 In a study23 of 32 dogs with spontaneously developing liver nodules, nodules that were hypoechoic in the portal and late phase were significantly (P < 0.001) associated with malignancy, and the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of this diagnostic approach were high (100%, 94%, 94%, 100%, and 97%, respectively). To this end, CEUS is a valuable alternative to invasive diagnostic procedures such as fine-needle aspiration or core biopsy.
Ultrasonographic images of the liver of a dog with hyperadrenocorticism. A—In a conventional US image, hepatomegaly is evident, and the liver parenchyma is hyperechoic. However, additional small, ill-defined hypoechoic areas (arrows) and 1 clearly outlined target nodule (open arrows) are evident. B—During the late phase of enhancement, CEUS (contrast-tuned imaging mode) reveals a diffusely homogenous liver parenchyma indicating the benign nature of the hypoechoic lesions.
Citation: Journal of the American Veterinary Medical Association 234, 4; 10.2460/javma.234.4.460
Examination of the spleen—Nodular splenic disease is common in dogs and can be caused by nonneoplastic (focal nodular hyperplasia, hematoma, infarct, or abscess) or neoplastic processes (hemangiosarcoma, lymphoma, malignant histiocytosis, or other mesenchymal tumors).51 A conventional US examination can distinguish among hypoechoic, hyperechoic, and complex focal splenic parenchymal abnormalities but cannot help to determine the etiology of the process. Moreover, there is a considerable overlap in the US appearance of focal splenic lesions,51–53 and splenic fine-needle aspirates only yield a correct diagnosis in 61.3% of affected dogs.54 Splenectomy followed by histologic examination is therefore often necessary to determine the prognosis and therapeutic options.51
Contrast-enhanced US of healthy spleens in dogs has revealed 2 vascular phases (Figure 5). In the early arterial phase, a nonhomogenous, patchy enhancement corresponds to variable flow rates through the cords and sinuses of the red pulp of the spleen and strongly complicates interpretation.26,55,56 Therefore, it is recommended that splenic assessment and lesion detection be performed during the delayed phase, at least 60 seconds after injection.26,56 During the delayed phase, the spleen becomes homogenously enhanced for about 5 to 7 minutes.26,55,56
Contrast–enhanced US images (contrast-tuned imaging mode) of a healthy canine spleen. The image from the arterial phase (A; 20 seconds after injection of contrast agent) reveals nonhomogenous enhancement (arrows) of the splenic parenchyma, followed by subsequent homogenous enhancement starting at approximately 50 seconds after contrast agent enhancement (B). This pattern suggests assessment of the spleen and its lesions should begin at 60 seconds to avoid misdiagnosis of hypoechoic lesions as malignant. Notice the presence of a moderate amount of free abdominal fluid caused by diffuse liver disease (asterisk).
Citation: Journal of the American Veterinary Medical Association 234, 4; 10.2460/javma.234.4.460
In the canine spleen, CEUS can help in the characterization of focal lesions, and hemangiosarcoma and lymphosarcoma have specific perfusion patterns.e The methodology can also be used for improving the visualization of infarction, detection of microabscesses or focal nodular lesions (Figure 6), and visualization of traumatic injuries15,55 (Figure 7).
Ultrasonographic images of a canine spleen. A—Conventional US reveals simultaneous presence of a nodular hyperplastic lesion (arrows) and a malignant mesenchymal neoplastic lesion (arrowheads), which appear as an ill-defined, small, isoechoic lesion and a large, heterogenous lesion, respectively. B—During the arterial phase of CEUS (contrast-tuned imaging mode), both lesions appear to have taken up the contrast agent. C—During the late phase of CEUS, sustained uptake of contrast agent is evident in the benign lesion, which is hyperechoic compared with the surrounding spleen, whereas the malignant lesion appears as a hypoechoic lesion because of its earlier loss of contrast agent.
Citation: Journal of the American Veterinary Medical Association 234, 4; 10.2460/javma.234.4.460
Ultrasonographic images of a dog with splenic trauma. A—Conventional US reveals an ill-defined, hypoechoic area with a lacy appearance at the parietal margin of the lesion (small arrows). B—Contrast-enhanced US (contrast-tuned imaging mode) reveals an extensive, irregular, and clearly outlined nonenhancing area (large arrows), which was surgically confirmed to be a large, subcapsular hematoma.
Citation: Journal of the American Veterinary Medical Association 234, 4; 10.2460/javma.234.4.460
Examination of the pancreas—In veterinary medicine, USCAs were only recently used to quantitatively assess vascular perfusion in healthy canine pancreasd,e and to detect abnormal vascular perfusion patterns in dogs with pancreatitis.e Significant differences in perfusion variables are evident between clinically normal dogs and dogs with pancreatitis.e
In humans, chronic mass-forming pancreatitis and pancreatic carcinoma have the same conventional US appearance and clinical symptoms. When USCAs are used, these 2 entities can be differentiated with an overall accuracy of 96% on the basis of differences in the intralesional parenchymographic phase.57 Owing to a massive desmoplastic reaction and low vascular density, pancreatic carcinomas remain hypoechoic throughout all vascular phases, unlike the nodules in chronic pancreatitis.57,58 This phenomenon also results in a differential uptake of contrast agent by pancreatic carcinomas and endocrine tumors such as insulinomas. Endocrine tumors appear hypervascular in contrast to carcinomas.58–60 These features allowed the authors to diagnose a carcinoma in 1 dog and an insulinoma in another (both of which were histologically confirmed) by means of a contrast-specific imaging techniquef that uses a low-frequency transducer and sulfur hexafluoride microbubblesg as a contrast agent.
Examination of kidneys—In evaluations of kidneys of human patients,13 dogs,61 and rabbits,28 USCAs yield more accurate morphologic and quantitative information about cortical vascularity than does power Doppler US. In healthy kidneys, use of USCAs results in early enhancement of the renal arteries during the arterial phase of vascular enhancement and subsequent homogenous enhancement of the renal cortical parenchyma and medulla, which become isoechoic with respect to the renal cortex27,62 (Figure 8). Vascular perfusion in healthy canine kidneys has been ultrasonographically evaluated with the aid of perflutren lipid microspheres.h Maximum enhancement of the renal cortex occurs at 15 seconds and of the renal medulla at 30 seconds after injection of contrast agent.27 The authors have used CEUS in the detection and characterization of focal renal mass–like lesions in 6 dogs (2 renal cell carcinomas, 2 hemangiosarcoma metastases, 1 simple renal cyst, and 1 hematoma) by use of an aforementioned contrast-specific imaging technique.f Therefore, we believe CEUS can potentially aid in the discrimination between primary and secondary malignant renal lesions and increase the ability to detect lesions, compared with conventional US. It also improves the detection of fluid-filled cavities.i
Time-intensity curves of the administration of contrast agent into a canine liver via a bolus injection (A) and an infusion (B) as detected via CEUS. After injection of a bolus of contrast agent, a typical wash-in–washout curve is obtained. There is a 2-phase dose response. A sharp rise in intensity is followed by a more gradual decrease during the washout phase. After infusion of contrast agent, enhancement is progressive with a subsequent plateau that persists until the end of the infusion.
Citation: Journal of the American Veterinary Medical Association 234, 4; 10.2460/javma.234.4.460
Examination of lymph nodes—Several changes evaluated by means of US can help in discriminating between healthy and diseased (inflammed, lymphomatous, or metastatic neoplastic) lymph nodes. The combination of lymph node size, distribution of vascular flow, and pulsatility index is reportedly the most accurate means of differentiating among these 4 diagnostic categories; the associated classification error is 23%.63 When only 2 diagnostic categories are used (benign or malignant), that error is reduced to 11%.63
Measurement of blood flow with Doppler modalities is possible in more than half of healthy lymph nodes and in slightly more than 80% of reactive and malignant nodes. The insensitivity is caused by a lack of detector sensitivity.63 In humans, signal enhancement with USCAs remarkably improves the sensitivity and provides better conspicuity of vessel morphology in all lymph nodes (2.13 times as many vessels are detectable via CEUS vs power Doppler US).64
Contrast-enhanced harmonic and power Doppler US have been used to characterize peripheral lymph nodes in dogs with lymphoma.29 In 81.8% of those dogs, fundamental US resulted in loss of the so-called hilus sign. However, CHUS with perflutren lipid microspheresh as a USCA resulted in increased detection of the fine angioarchitecture of the lymph nodes, compared with the detection ability of power Doppler US. Hence, CHUS resulted in a more accurate characterization of affected lymph nodes. In the same study29 of 11 canine peripheral lymph nodes evaluated via CHUS, 45% had displacement of the central hilar vessels, 45% had aberrant vessels, 64% had pericapsular vessels, and 36% had subcapsular vessels.
When staging cancer, a finding of lymph node metastases is an important prognostic determinant and guides proper choice of treatment. The sentinel lymph node is defined as the first node to receive lymphatic drainage from a neoplasm. Radioactive technetium scintigraphy or injection of blue dye into or near a tumor is used to detect a sentinel lymph node.65,66 In dogs injected SC with a USCA, microbubbles can yield contrastenhanced power Doppler signals in 85% of the sentinel lymph nodes.66 When smaller bubbles are used, the percentage of signals in the lymph node increases to 94%.66 It must be emphasized that these findings are specific to superficial lymph nodes, and additional studies are needed to assess the behavior of USCAs in abdominal lymph nodes.
Vascular application—Initial results achieved when CHUS was used in 3 dogs with congenital extrahepatic portosystemic shunts indicated shorter times to peak perfusion in the liver (7.0 ± 2.0 seconds), compared with results in clinically normal dogs (22.8 ± 6.8 seconds).31 This finding suggests increased hepatic arterial blood flow in dogs with shunts, compared with those without shunts, and supports the diagnosis of a shunt.31 However, CEUS was not able to increase the visibility of the shunt vessel.
Quantification of USCAs via time-intensity curves—Quantification of USCAs is of fundamental importance because it allows objective evaluation of the degree of tissue perfusion and detection of diffuse tissue changes.14,67,68 A USCA can be used as a tracer for dynamic evaluations of organs such as the liver, kidney, or brain. In addition, the arteriovenous transit time of a USCA can be digitally processed, and the resulting time-intensity curves will allow measurement of the rate of uptake and clearance of contrast agent in a specific location.15,68
In the past few years, several sophisticated US systems have been developed to include a built-in software package that generates time-intensity curves.14,67,69,70 Compared with US units that use external software, such systems result in a reduction in errors. This is attributable to a decrease in the electronic transfer of the images between various machines, which causes loss of image quality. Furthermore, the measurement system is standardized.14 With these software systems, ROIs can be drawn to highlight vessels or areas within the adjacent parenchyma.67,70–72 For each ROI, the gray-scale or Doppler signal changes can be calculated during a certain duration and displayed as a timeintensity curve.67,71,72 Mathematic analysis of these curves yields quantitative hemodynamic indices relating to blood flow within volumes of tissue or within single vessels.6,67,71–75
After IV bolus injection of a USCA, a time-intensity curve will have a characteristic dilution shape consisting of a 2-phase dose response70,74 (Figure 9). The first phase is indicated as a rapid rise in intensity followed by a rapid linear decrease during an early phase in which the contrast agent is eliminated (so-called washout phase). The phase 1 kinetics correspond to the first pass of contrast agent through the arterial circulation followed by the distribution of the USCA. These kinetics depend on cardiac output, dose of contrast agent administered, and size of the ROI.74,76 The second phase is indicated by a slow linear decrease of the washout phase and is the predominant effect detected after IV injection in terms of duration. The kinetics of phase 2 represent the recirculation of contrast agent between arterial and venous circulation. These kinetics depend on the elimination of contrast agent from the blood pool, dose of contrast agent administered, and size of the ROI but not on cardiac output. The first phase is much shorter than the second phase.74,76 In sequences associated with constant rate infusions, the time-intensity curves will indicate progressive enhancement with a plateau-like enhancement profile that persists until infusion is concluded.70,71 Changes in vascularity and blood flow secondary to pathologic processes are represented in the time-intensity curve as alterations of its shape.14,67
Contrast-enhanced US images (contrast-tuned imaging mode) of the vascular enhancement phases of healthy canine kidneys. Early enhancement of the renal interlobar arteries (arrows) is evident during the arterial phase (A), with immediate subsequent homogenous enhancement of the renal cortical parenchyma (approx 15 seconds after contrast agent injection; B) and medulla (approx 30 seconds after contrast agent injection; C), which becomes isoechoic with respect to the renal cortex.
Citation: Journal of the American Veterinary Medical Association 234, 4; 10.2460/javma.234.4.460
Time-intensity perfusion curves have been generated for the liver,24,45,a spleen,26 pancreas,e and kidneys27 of clinically normal dogs. Choice of anesthetic protocol in dogs with healthy livers can influence perfusion indices from time-intensity curves.45
Comparison of CEUS With Other Diagnostic Modalities
In human medicine, CEUS (in combination with Doppler US) is equivalent to dynamic computed tomography and superior (higher sensitivity and specificity) to Doppler US for the diagnosis of blood flow abnormalities in patients with macrovascular diseases (stenosis, thrombosis, or abnormal portal collateral vessels) of the portal venous system, kidney, and liver.6,7,22,77–78 Contrastenhanced US is also superior to CECT and equivalent to CEMRI in characterization of focal liver lesions.15,49,79,80
Detection of liver metastases with CEUS is as sensitive and accurate as detection with CECT, if not more so.34,46,81,82 Lesions measuring up to 5 mm are clearly revealed via CEUS, and even lesions < 5 mm can be detected.78,81,83,84
Unlike CECT and CEMRI, CEUS permits realtime analysis of tumor perfusion, which provides better temporal resolution, and does not require that subjects be anesthetized.43,85 In addition, compared with CECT and CEMRI, CEUS is more cost-effective, can be performed faster, and does not involve ionizing radiation. As such, CEUS represents a competitive alternative to the established imaging methods.34,39,79,81
Compared with cytologic evaluation of fine-needle aspirates or histologic examination of tissues, CEUS has higher specificity41,42 and is also noninvasive and relatively easy to perform and discriminates well between benign and malignant processes.23
Potential Limitations of CEUS
Safety factors—In general, USCAs are well tolerated for abdominal examinations, with few adverse reactions reported. In humans, reported adverse events are typically minor (eg, headache, nausea, altered taste, or sensation of heat) and self-resolving.6,86 In Europe, USCAs are widely used in human medicine without particular restriction. In the United States, however, USCA use in humans is highly regulated because of the potential for serious cardiopulmonary reactions. In October 2007, the FDA issued a warning on the use of perfluorocarbon-based USCAs (eg, perflutren lipid microspheresh and perflutren protein–type A microspheresj) for echocardiography and stated that the use of such products in humans with unstable cardiopulmonary status is contraindicated.87 Use of USCAs in veterinary medicine has not been approved by the FDA. Therefore, use of USCAs in animals is strictly extralabel. To the authors' knowledge, no adverse reactions in dogs have been reported.
Stability and price of USCAs—Once reconstituted, a USCA remains stable only for several hours, depending on the agent used (maximum of 6 hours for sulfur hexafluorideg and 12 hours for perflutren lipid microspheresh). This means that a new vial of contrast agent must be used for each US subject, which substantially increases the cost for pet owners. In the United States, 1 vial of contrast agent costs approximately $150. This limitation can be overcome by scheduling several subjects within the same period so that 1 vial can be used, resulting in less wastage and reduced cost.
Need for adequate equipment—Performance of CEUS requires sophisticated US machines, which must be equipped with Doppler modalities, special low-frequency transducers, software that permits performance of contrast-specific imaging, and, eventually, software for quantitative evaluation of CEUS images. The dependence on such machines also adds to the cost of CEUS.
Future Possibilities for CEUS
Targeted (molecular) imaging—Because their size prevents extravasation, the currently used USCAs are in fact passively (nonspecifically) targeted to the blood pool. Some microbubbles, which are as yet unavailable in the United States, are able to preferentially accumulate in tissues such as the liver (NC100100,k SHU563A,l and SHU508Am),6,11,48 spleen (sulfur hexafluorideg),88 or activated endothelium. The mechanisms of this nonspecific targeting are poorly understood but likely depend on the properties of the shell and resting diameter of the contrast agent.11,89 Novel tissue-specific (active targeting) USCAs have recently been developed, and these agents can improve the assessment of certain organs by increasing the contrast resolution attributable to preferential uptake by the organs.90,91
Several strategies have been used to target USCAs to diseased areas. The most common method of active targeting is incorporation of bioactive adhesion molecules (antibodies, peptides, or other ligands), which recognize disease-related antigens (receptors), into microbubble shells, resulting in so-called targeted USCAs.13,78
Of the many available molecular markers, those used in targeted US have so far been limited to markers administered via IV injection.11 Because microbubbles are intravascular agents, the assessed disease processes must be characterized by antigens that are expressed within the vascular compartment.91 Therefore, these targeted USCAs can be used to highlight inflammation (by conjugating ligands [monoclonal antibodies] to their surface, which then bind to endothelial cell adhesion molecules [ICAM-1, P-selectin, or VCAM-1]), activated IV thrombi (via USCAs that bind to glycoprotein IIb/IIIa receptors, which are abundant at the surface of activated platelets), tumors (neoplastic endothelial cells overexpress integrins AvB3 and AvB5, which can bind to polymeric microbubbles conjugated with a generic peptide sequence arginine-glycine-aspartatic acid), and lymph nodes (via antibody on microbubble surface that targets the L-selectin ligand expressed in lymph node venules).11,89,91–94
Therapeutic applications—Other concepts that are being explored include targeted drug delivery that makes use of the aforementioned targeted microbubbles. Because of their special acoustic and biological properties, microbubbles can be very promising as a vehicle for drug and gene delivery. Their most exciting application is in gene therapy, in which the delivery of genetic material to a chosen site is difficult.6,78 Microbubbles can be loaded (encased within the membrane or attached on the membrane) with active substances such as nucleotidic chains. These loaded, targeted microbubbles can be tracked via US until they reach their targeted area. When high US energy is used, the microbubbles can be ruptured to locally deliver genes to a tissue.6,78,92
Conclusion
Contrast-enhanced US can be used in dogs to increase the intensity of the bloodpool echo signal. Its main indication is the assessment of focal lesions in the liver and spleen, particularly for differentiation between benign and malignant processes. Evidence suggests that CEUS is a valuable alternative to invasive diagnostic procedures such as fine-needle aspiration or core biopsy. The diagnostic method allows real-time analysis of tumor perfusion, does not require that subjects be anesthetized, has no ionizing radiation, can be performed quickly, and is more accurate, compared with fine-needle aspiration or core biopsy. As promising results in human medicine have suggested, USCAs can also be useful as vehicles for drug and gene delivery. The most important disadvantages of CEUS include poor stability of USCAs and the need for specialized equipment, which increase the cost of this imaging technique. Moreover, in humans, some adverse effects associated with administration of USCAs have been reported.
Abbreviations
CECT | Contrast-enhanced computed tomography |
CEMRI | Contrast-enhanced magnetic resonance imaging |
CEUS | Contrast-enhanced ultrasonography |
CHUS | Contrast (second) harmonic ultrasonography |
ROI | Region of interest |
US | Ultrasonography |
USCA | Ultrasonographic contrast agent |
References
- 1.↑
Cachard C, Finet G, Bouakaz A, et al. Ultrasound contrast agent in intravascular echography: an in vitro study. Ultrasound Med Biol 1997;23:705–717.
- 2.
Forsberg F, Basude R, Liu J-B, et al. Effect of filling gases on the backscatter from contrast microbubbles: theory and in vivo measurements. Ultrasound Med Biol 1999;25:1203–1211.
- 3.
Shi WT, Forsberg F, Bautista R, et al. Image enhancement by acoustic conditioning of ultrasound contrast agents. Ultrasound Med Biol 2004;30:191–198.
- 4.
Calliada F, Campani R, Bottinelli O, et al. Ultrasound contrast agents: basic principles. Eur J Radiol 1998;27 (suppl 2):S157–S160.
- 5.
Wilson SR, Burns PN. Liver mass evaluation with ultrasound: the impact of microbubble contrast agents and pulse inversion imaging. Semin Liver Dis 2001;21:147–159.
- 6.↑
Correas JM, Bridal L, Lesavre A, et al. Ultrasound contrast agents: properties, principles of action, tolerance, and artifacts. Eur Radiol 2001;11:1316–1328.
- 7.
Fischer G, Rak R, Sackmann M. Improved investigation of portal-hepatic veins by echo-enhanced Doppler sonography. Ultrasound Med Biol 1998;24:1345–1349.
- 8.
Droste DW, Kaps M, Navabi DG, et al. Ultrasound contrast enhancing agents in neurosonology: principles, methods, future possibilities. Acta Neurol Scand 2000;102:1–10.
- 9.
Forsberg F, Piccoli CW, Liu J-B, et al. Hepatic tumor detection: MR imaging and conventional US versus pulse-inversion harmonic US of NC100100 during its reticuloendothelial system-specific phase. Radiology 2002;222:824–829.
- 10.↑
de Jong N, Frinking PJ, Bouakaz A, et al. Detection procedures of ultrasound contrast agents. Ultrasonics 2000;38:87–92.
- 12.
Bloch SH, Dayton PA, Ferrara KW. Targeted imaging using ultrasound contrast agents. Progess and opportunities for clinical and research applications. IEEE Eng Med Biol Mag 2004;23:18–29.
- 14.↑
Maresca G, Summaria V, Colagrande C, et al. New prospects for ultrasound contrast agents. Eur J Radiol 1998;27 (suppl 2):S171–S178.
- 15.
Albrecht T, Hohmann J. Contrast agents in sonography. Toshiba VISIONS 2004;6:3–25.
- 16.
Robbin ML, Lockhart ME, Barr RG. Renal imaging with ultrasound contrast: current status. Radiol Clin North Am 2003;41:963–978.
- 17.
Whittingham TA. Contrast-specific imaging techniques: technical perspective. In: Quaia E, ed. Contrast media in ultrasonography: basic principles and clinical applications. Berlin: Springer-Verlag Inc, 2005;58–62.
- 18.
Eckersley RJ, Chin CT, Burns PN. Optimising phase and amplitude modulation schemes for imaging microbubble contrast agents at low acoustic power. Ultrasound Med Biol 2005;31:213–219.
- 19.
Simpson DH, Ting Chi. C, Burns PN. Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents. Ferroelectr Freq Control 1999;46:372–382.
- 20.↑
Shankar PM, Krishna PD, Newhouse VL. Advantages of subharmonic over second harmonic backscatter for contrast-to-tissue echo enhancement. Ultrasound Med Biol 1998;24:395–399.
- 21.
Borsboom JM, Chin CT, de Jon. N. Nonlinear coded excitation method for ultrasound contrast imaging. Ultrasound Med Biol 2003;29:277–284.
- 22.
Bahr A, Wrigley R, Salman M. Quantitative evaluation of imagent as an abdominal ultrasound contrast medium in dogs. Vet Radiol Ultrasound 2000;41:50–55.
- 23.↑
O'Brien RT, Iani M, Matheson J, et al. Contrast harmonic ultrasound of spontaneous liver nodules in 32 dogs. Vet Radiol Ultrasound 2004;45:547–553.
- 24.
Ziegler LE, O'Brien RT, Waller KR, et al. Quantitative contrast harmonic ultrasound imaging of normal canine liver. Vet Radiol Ultrasound 2003;44:451–454.
- 25.↑
O'Brien RT. Improved detection of metastatic hepatic hemangiosarcoma nodules with contrast ultrasound in three dogs. Vet Radiol Ultrasound 2007;48:146–148.
- 26.↑
Ohlerth S, Rüefli E, Poirier V, et al. Contrast harmonic imaging of the normal canine spleen. Vet Radiol Ultrasound 2007;48:451–456.
- 27.↑
Waller KR, O'Brien RT, Zagzebski JA. Quantitative contrast ultrasound analysis of renal perfusion in normal dogs. Vet Radiol Ultrasound 2007;48:373–377.
- 28.↑
Taylor GA, Ecklund K, Dunning PS. Renal cortical perfusion in rabbits: visualisation with color amplitude imaging and an experimental microbubble-based US contrast agent. Radiology 1996;201:125–129.
- 29.↑
Salwei RM, O'Brien RT, Matheson JS. Characterisation of lymphomatous lymph nodes in dogs using contrast harmonic and Power Doppler ultrasound. Vet Radiol Ultrasound 2005;46:411–416.
- 30.↑
Schärz M, Ohlerth S, Achermann R, et al. Evaluation of quantified contrast-enhanced color and power Doppler ultrasonography for the assessment of vascularity and perfusion of naturally occurring tumors in dogs. Am J Vet Res 2005;66:21–29.
- 31.↑
Salwei RM, O'Brien RT, Matheson JS. Use of contrast harmonic ultrasound for the diagnosis of congenital portosystemic shunts in three dogs. Vet Radiol Ultrasound 2003;44:301–305.
- 32.
Wilson SR, Burns PN, Muradali D, et al. Harmonic hepatic US with microbubble contrast agent: initial experience showing improved characterization of hemangioma, hepatocellular carcinoma, and metastasis. Radiology 2000;215:153–161.
- 33.↑
Dietrich CF. Characterisation of focal liver lesions with contrast enhanced ultrasonography. Eur J Radiol 2004;51S:S9–S17.
- 34.
EFSUMB Study Group. Guidelines for the use of contrast agents in ultrasound. Ultraschall Med 2004;25:249–256.
- 35.↑
Bergman JR. Nodular hyperplasia in the liver of the dog: an association with changes in the Ito cell population. Vet Pathol 1985;22:427–438.
- 36.
Patnaik AK, Hurvitz AI, Lieberman PH. Canine hepatic neoplasms: a clinicopathologic study. Vet Pathol 1980;17:553–564.
- 37.
Nyland TG, Mattoon JS, Herrgesell EJ, et al. Liver. In: Nyland TG, Mattoon JS, eds. Small animal diagnostic ultrasound. 2nd ed. Philadelphia: WB Saunders Co, 2002;93–127.
- 38.↑
Dietrich CF, Ignee A, Trojan J, et al. Improved characterisation of histologically proven liver tumours by contrast enhanced ultrasonography during the portal venous and specific late phase of SHU 508A. Gut 2004;53:401–405.
- 39.
Bryant TH, Blomley MJ, Albrecht T, et al. Improved characterization of liver lesions with liver-phase uptake of liver-specific microbubbles: prospective multicenter study. Radiology 2004;232:799–809.
- 40.
von Herbay A, Vogt C, Willers R, et al. Real-time imaging with the sonographic contrast agent SonoVue; differentiation between benign and malignant hepatic lesions. J Ultrasound Med 2004;23:1557–1568.
- 41.
Cohen M, Bohling MW, Wright JC, et al. Evaluation of sensitivity and specificity of cytologic examination: 269 cases (1999–2000). J Am Vet Med Assoc 2003;222:964–967.
- 42.
Wang KY, Panciera DL, Al-Rukibat RK, et al. Accuracy of ultrasound-guided fine-needle aspiration of the liver and cytologic findings in dogs and cats: 97 cases (1990–2000). J Am Vet Med Assoc 2004;224:75–78.
- 43.
Brannigan M, Burns PN, Wilson SR. Blood flow patterns in focal liver lesions at microbubble-enhanced US. Radiographics 2004;24:921–935.
- 44.
Nyman HT, Kristensen AT, Flagstad A, et al. A review of the sonographic assessment of tumor metastases in liver and superficial lymph nodes. Vet Radiol Ultrasound 2004;45:438–448.
- 45.↑
Nyman HT, Kristensen AT, Kjelgaard-Hansen M, et al. Contrast-enhanced ultrasonography in normal canine liver. Evaluation of imaging and safety parameters. Vet Radiol Ultrasound 2005;46:243–250.
- 46.
Oldenburg A, Hohmann J, Foert E, et al. Detection of hepatic metastases with low MI real time contrast enhanced sonography and SonoVue. Ultraschall Med 2005;26:277–284.
- 47.
Blomley MJK, Albrecht T, Cosgrove DO, et al. Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: early experience. Radiology 1999;210:409–416.
- 48.
Harvey CJ, Blomley MJK, Eckersley RJ, et al. Hepatic malignancies: improved detection with Pulse-Inversion US in late phase of enhancement with SHU 508A. Early experience. Radiology 2000;216:903–908.
- 49.
Burns PN, Wilson SR. Focal liver masses: enhancement patterns on contrast-enhanced images—concordance of US scans with CT scans and MR images. Radiology 2007;242:162–174.
- 50.
Quaia E, Palumbo A. Contrast-specific imaging techniques: methodological point of view. In: Quaia E, ed. Contrast media in ultrasonography: basic principles and clinical applications. Berlin: Springer-Verlag Inc, 2005;71–75.
- 52.
Feeney DA, Johnston GR, Hardy RM. Two-dimensional, grayscale ultrasonography for assessment of hepatic and splenic neoplasia in the dog and cat. J Am Vet Med Assoc 1984;184:68–81.
- 53.
Wrigley RH, Park RD, Konde LJ, et al. Ultrasonographic features of splenic hemangiosarcoma in dogs: 18 cases (1980–1986). J Am Vet Med Assoc 1988;192:1113–1117.
- 54.↑
Ballegeer EA, Forrest LJ, Dickinson RM, et al. Correlation of ultrasonographic appearance of lesions and cytologic and histologic diagnoses in splenic aspirates from dogs and cats: 32 cases (2002–2005). J Am Vet Med Assoc 2007;230:690–696.
- 55.
Catalano O, Sandomenico F, Matarazzo I, et al. Contrast-enhanced sonography of the spleen. AJR Am J Roentgenol 2005;184:1150–1156.
- 56.
Harvey CJ, Lim AKP, Lynch M, et al. Applications of ultrasound microbubbles in the spleen. In: Quaia E, ed. Contrast media in ultrasonography: basic principles and clinical applications. Berlin: Springer-Verlag Inc, 2005;205–217.
- 57.↑
D'Onofrio M, Zamboni G, Tognolini A, et al. Mass-forming pancreatitis: value of contrast-enhanced ultrasonography. World J Gastroenterol 2006;12:4181–4184.
- 58.
D'Onofrio M, Martone E, Malagò R, et al. Contrast-enhanced ultrasonography of the pancreas. JOP 2007;8 (suppl 1) 71–76.
- 59.
Kitano M, Kudo M, Maekawa K, et al. Dynamic imaging of pancreatic diseases by contrast enhanced coded phase inversion harmonic ultrasonography. Gut 2004;53:854–859.
- 60.
Yang W, Chen MH, Yan K, et al. Differential diagnosis of nonfunctional islet cell tumor and pancreatic carcinoma with sonography. Eur J Radiol 2007;62:342–351.
- 61.↑
Abildgaard A, Klow NE, Jakobsen JA, et al. Effect of ultrasound contrast medium in color Doppler and power Doppler visualisation of blood flow in canine kidneys. Acta Radiol 1997;38:445–453.
- 62.
Thorelius L. Contrast-enhanced ultrasound for extrahepatic lesions: preliminary experience. Eur J Radiol 2004;(suppl 51):S31–S38.
- 63.↑
Nyman HT, Kristensen AT, Skovgaard IM, et al. Characterization of normal and abnormal canine superficial lymph nodes using gray-scale B-mode, color flow mapping, power, and spectral Doppler ultrasonography: a multivariate study. Vet Radiol Ultrasound 2005;46:404–410.
- 64.↑
Schroeder RJ, Maerurer J, Gath HJ, et al. Vascularization of reactively enlarged lymph nodes analyzed by color duplex sonography. J Oral Maxillofac Surg 1999;57:1090–1095.
- 65.
Goldberg BB, Merton DA, Liu J-B, et al. Sentinel lymph nodes in a swine model with melanoma: contrast-enhanced lymphatic US. Radiology 2004;230:727–734.
- 66.↑
Wisner ER, Ferrara KW, Short RE, et al. Sentinel node detection using contrast-enhanced power Doppler ultrasound lymphography. Invest Radiol 2003;38:358–365.
- 67.
Maruyama H, Matsutani S, Saisho H, et al. Real-time blood-pool images of contrast enhanced ultrasound with Definity in the detection of tumour nodules in the liver. Br J Radiol 2005;78:512–518.
- 68.
Schmid V, Lang J. Intravascular ultrasound contrast media. Vet Radiol Ultrasound 1995;36:307–314.
- 69.
Blomley MJ, Albrecht T, Cosgrove DO, et al. Liver vascular transit time analyzed with dynamic hepatic venography with bolus injections of an US contrast agent: early experience in seven patients with metastases (Erratum published in Radiology 1998;210:882). Radiology 1998;209:862–866.
- 70.
Lefèvre F, Correas JM, Briançon S, et al. Contrast-enhanced sonography of the renal transplant using triggered pulse-inversion imaging: preliminary results. Ultrasound Med Biol 2002;28:303–314.
- 71.
Okada M, Hoffmann CW, Wolf KJ, et al. Bolus versus continuous infusion of microbubble contrast agent for liver US: initial experience. Radiology 2005;237:1063–1067.
- 72.
Caruso G, Salvaggio G, Sorrentino F, et al. Cerebral vessels. In: Quaia E, ed. Contrast media in ultrasonography: basic principles and clinical applications. Berlin: Springer-Verlag Inc, 2005;92.
- 73.
Bang N, Nielsen MB, Rasmussen AN, et al. Hepatic vein transit time of an ultrasound contrast agent: simplified procedure using pulse inversion imaging. Br J Radiol 2001;74:752–755.
- 74.
Schwarz KQ, Chen X, Bezante GP, et al. The Doppler kinetics of microbubble echo contrast. Ultrasound Med Biol 1996;22:453–462.
- 75.
Krix M, Kiessling F, Vosseler S, et al. Comparison of intermittent-bolus contrast imaging with conventional power Doppler sonography: quantification of tumour perfusion in small animals. Ultrasound Med Biol 2003;29:1093–1103.
- 76.
Ordén MR, Jurvelin JS, Kirkinen PP. Kinetics of a US contrast agent in benign and malignant adnexal tumors. Radiology 2003;226:405–410.
- 77.
Gebel M, Caselitz M, Bowen-Davies PE, et al. A multicenter, prospective, open label, randomized, controlled phase IIIb study of SHU 508A (Levovist) for Doppler signal enhancement in the portal vascular system. Ultraschall Med 1998;19:148–156.
- 78.
Blomley MJK, Cooke JC, Unger EC, et al. Microbubble contrast agents: a new era in ultrasound. BMJ 2001;322:1222–1225.
- 79.
Ricci P, Laghi A, Cantisani V, et al. Contrast-enhanced sonography with SonoVue: enhancement patterns of benign focal liver lesions and correlation with dynamic gadobenate dimeglumineenhanced MRI. AJR Am J Roentgenol 2005;184:821–827.
- 80.
Oudkerk M, Torres CG, Song B, et al. Characterization of liver lesions with mangafodipir trisodium-enhanced MR imaging: multicenter study comparing MR and dual-phase spiral CT. Radiology 2002;223:517–524.
- 81.
Albrecht T, Blomley MJ, Burns PN, et al. Improved detection of hepatic metastases with pulse-inversion US during the liver-specific phase of SHU 508A: multicenter study. Radiology 2003;227:361–370.
- 82.
Quaia E, D'Onofrio M, Palumbo A, et al. Comparison of contrast-enhanced ultrasonography versus baseline ultrasound and contrast-enhanced computed tomography in metastatic disease of the liver: diagnostic performance and confidence. Eur Radiol 2006;16:1599–1609.
- 83.
Albrecht T, Hoffmann CW, Schmitz SA, et al. Phase-inversion sonography during the liver-specific late phase of contrast enhancement: improved detection of liver metastases. AJR Am J Roentgenol 2001;176:1191–1198.
- 84.
Lee JM, Youk JH, Lee YH, et al. Detection of hepatic VX2 tumors in rabbits: comparison of conventional US and phase-inversion harmonic US during the liver-specific late phase of contrast enhancement. Korean J Radiol 2003;4:124–129.
- 85.
Quaia E, D'Onofrio M, Bartolotta TV, et al. Characterzation of focal liver lesions. In: Quaia E, ed. Contrast media in ultrasonography: basic principles and clinical applications. Berlin: Springer-Verlag Inc, 2005;126–127.
- 86.
Jakobsen JA, Oyen R, Thomsen HS, et al. Safety of ultrasound contrast agents. Eur Radiol 2005;15:941–945.
- 87.↑
US FDA Web site. Micro-bubble contrast agents (marketed as Definity (perflutren lipid microspheres) injectable suspension and Optison (perflutren protein-type A microspheres for injection). FDA Alert (10/2007). Available at: www.fda.gov/cder/drug/infopage/microbubble/default.htm. Accessed May 10, 2008.
- 88.↑
Lim AK, Patel N, Eckersley RJ, et al. Evidence for spleen-specific uptake of a microbubble contrast agent: a quantitative study in healthy volunteers. Radiology 2004;231:785–788.
- 89.
Blomley M. Can microbubbles be targeted to lymph nodes? Radiology 2004;231:611–612.
- 90.
Forsberg F, Merton DA, Liu J-B, et al. Clinical applications of ultrasound contrast agents. Ultrasonics 1998;36:695–701.
- 91.↑
Lindner JR. Molecular imaging with contrast ultrasound and targeted microbubbles. J Nucl Cardiol 2004;11:215–221.
- 92.
Dijkmans PA, Juffermans LJ, Musters RJ, et al. Microbubbles and ultrasound: from diagnosis to therapy. Eur J Echocardiogr 2004;5:245–256.
- 93.
Hauff P, Reinhardt M, Briel A, et al. Molecular targeting of lymph nodes with L-selectin ligand-specific US contrast agent: a feasibility study in mice and dogs. Radiology 2004;231:667–673.
- 94.
Martin MJ, Chung EM, Goodall AH, et al. Enhanced detection of thromboemboli with the use of targeted microbubbles. Stroke 2007;38:2726–2732.
Hause A, Kiefer I, Succow D, et al. Hepatic transit time of the signal enhancer SonoVue in the dog (abstr), in Proceedings. Int Vet Radiol Assoc/Am Coll Vet Radiol Conf 2006;38.
Ivancic-Arndt M, Seiler G. Contrast harmonic ultrasound of splenic hemangiosarcoma and associated liver nodules in dogs (abstr), in Proceedings. Am Coll Vet Radiol Annu Sci Meet 2007;19.
Rossi F, Vignoli M, Leone VF, et al. Use of contrast harmonic ultrasound for the characterization of focal lesions of the spleen (abstr), in Proceedings. Int Vet Radiol Assoc/Am Coll Vet Radiol Conf 2006;40.
Gaschen L, Schur D, Kearney M. Contrast harmonic ultrasound imaging of the normal pancreas and pancreatitis in dogs (abstr), in Proceedings. Am Coll Vet Radiol Annu Sci Meet 2007;21.
Johnson-Neitman JL, O'Brien RT, Wallace JD. Quantitative perfusion analysis of the normal canine pancreas and duodenum using contrast-enhanced harmonic ultrasound (abstr), in Proceedings. Am Coll Vet Radiol Annu Sci Meet 2007;20.
Contrast Tuned Imaging (CnTI), Esaote, Genoa, Italy.
SonoVue, Bracco Diagnostics Inc, Milan, Italy.
Definity, Bristol-Myers Squibb, North Billerica, Mass.
Haers H, Vignoli M, Paes G, et al. Contrast-enhanced ultrasonography of focal renal lesions (abstr), in Proceedings. Eur Vet Diagn Imaging Annu Meet 2008;68.
Optison, Amersham Health, Princeton, NJ.
Sonazoid, Nycomed Imaging, Oslo, Norway.
Sonavist, Schering AG, Berlin, Germany.
Levovist, Schering AG, Berlin, Germany.