Evaluation of a cow-side immunoassay kit for assessing IgG concentration in colostrum

Munashe ChigerweDepartments of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO 65211.

Search for other papers by Munashe Chigerwe in
Current site
Google Scholar
PubMed
Close
 BVSc
,
Maisie E. DawesDepartments of Veterinary Pathobiology, Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO 65211.

Search for other papers by Maisie E. Dawes in
Current site
Google Scholar
PubMed
Close
 DVM
,
Jeff W. TylerDepartments of Veterinary Pathobiology, Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO 65211.

Search for other papers by Jeff W. Tyler in
Current site
Google Scholar
PubMed
Close
 DVM, PhD, DACVIM
,
John R. MiddletonDepartments of Veterinary Pathobiology, Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO 65211.

Search for other papers by John R. Middleton in
Current site
Google Scholar
PubMed
Close
 DVM, PhD, DACVIM
,
Malantus P. MooreDepartments of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO 65211.

Search for other papers by Malantus P. Moore in
Current site
Google Scholar
PubMed
Close
 BS
, and
Dusty M. NagyDepartments of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO 65211.

Search for other papers by Dusty M. Nagy in
Current site
Google Scholar
PubMed
Close
 DVM, MS, DACVIM
View More View Less

Abstract

Objective—To determine sensitivity and specificity of a cow-side immunoassay kit for assessing IgG concentration in colostrum.

Design—Prospective study.

Animals—76 dairy and 11 beef cows of various parities.

Procedure—Colostrum from first, second, and third milkings and milk samples were collected, and IgG concentration was determined by means of radial immunodiffusion. The immunoassay was performed according to the manufacturer’s instructions, and sensitivity and specificity were calculated by comparing results of the immunoassay (positive vs negative) with results of immunodiffusion (< 50 g/L vs ≥ 50 g/L).

Results—135 colostrum or milk samples were collected. Mean ± SD colostral IgG concentrations, determined by means of radial immunodiffusion for dairy and beef cows were 65.4 ± 51.4 g/L and 114.8 ± 42.7 g/L, respectively. Mean IgG concentrations for first-, second-, and third-milking colostrum samples and for milk samples were 92 ± 49.0 g/L, 74.6 ± 45.1 g/L, 47.5 ± 32 g/L, and 6.8 ± 3.8 g/L, respectively. Sensitivity of the immunoassay (ie, percentage of samples with IgG concentration < 50 g/L with a positive immunoassay result) was 93%, and specificity (ie, percentage of samples with IgG concentration ± 50 g/L with a negative immunoassay result) was 76%.

Conclusions and Clinical Relevance—Results suggested that the immunoassay kit was an acceptable cow-side test to identify colostrum samples with IgG concentrations < 50 g/L. The immunoassay kit should be useful in screening colostrum for adequate IgG concentration before feeding to calves or storage. (J Am Vet Med Assoc 2005;227:129–131)

Abstract

Objective—To determine sensitivity and specificity of a cow-side immunoassay kit for assessing IgG concentration in colostrum.

Design—Prospective study.

Animals—76 dairy and 11 beef cows of various parities.

Procedure—Colostrum from first, second, and third milkings and milk samples were collected, and IgG concentration was determined by means of radial immunodiffusion. The immunoassay was performed according to the manufacturer’s instructions, and sensitivity and specificity were calculated by comparing results of the immunoassay (positive vs negative) with results of immunodiffusion (< 50 g/L vs ≥ 50 g/L).

Results—135 colostrum or milk samples were collected. Mean ± SD colostral IgG concentrations, determined by means of radial immunodiffusion for dairy and beef cows were 65.4 ± 51.4 g/L and 114.8 ± 42.7 g/L, respectively. Mean IgG concentrations for first-, second-, and third-milking colostrum samples and for milk samples were 92 ± 49.0 g/L, 74.6 ± 45.1 g/L, 47.5 ± 32 g/L, and 6.8 ± 3.8 g/L, respectively. Sensitivity of the immunoassay (ie, percentage of samples with IgG concentration < 50 g/L with a positive immunoassay result) was 93%, and specificity (ie, percentage of samples with IgG concentration ± 50 g/L with a negative immunoassay result) was 76%.

Conclusions and Clinical Relevance—Results suggested that the immunoassay kit was an acceptable cow-side test to identify colostrum samples with IgG concentrations < 50 g/L. The immunoassay kit should be useful in screening colostrum for adequate IgG concentration before feeding to calves or storage. (J Am Vet Med Assoc 2005;227:129–131)