The indications most commonly cited for esophageal surgery in dogs and cats are foreign body retrieval and esophageal stricture.1 Historically, surgery of the esophagus has been associated with a higher incidence of postoperative complications than for any other segment of the gastrointestinal tract.2 Approximately 50% of dogs and 33% of cats have complications after esophageal surgery, and 20% to 50% of humans have wound dehiscence after esophagectomy procedures.1 The complications most commonly recorded for veterinary species after esophagotomy are dehiscence, esophageal strictures, regurgitation, and aspiration pneumonia.1–4 The causes of death or euthanasia most commonly reported are severe respiratory distress and sepsis.1 It is presumed that optimizing mucosal apposition and minimizing incisional tension will reduce the incidence of strictures and dehiscence.2–5
Currently, there is no definite consensus regarding the proper technique for closure of an esophagotomy. In 1 retrospective study1 of data from 7 institutions, 52% of esophageal surgeries were closed in a single layer, 41% were closed in 2 layers, and 7% of closures were not recorded.1 Investigators of 1 study6 determined that double-layer simple interrupted closure results in better mucosal apposition and higher immediate bursting wall tension (3.5 × 105 dynes/cm) than single-layer simple interrupted (0.5 × 105 dynes/cm) and simple continuous (0.9 × 105 dynes/cm) closures, but double-layer closure requires significantly more time to complete and is more technically challenging.6
To the authors' knowledge, use of a double-layer simple continuous pattern has not been investigated. The objective of the study reported here was to evaluate leak pressure and closure time for double-layer esophagotomy closure with an interrupted suture pattern and a simple continuous suture pattern. It was hypothesized that a double-layer simple continuous pattern would require less time to complete but would achieve a similar postoperative leak pressure, compared with closure time and postoperative leak pressure for a double-layer simple interrupted closure.
Materials and Methods
Sample
Segments of the intrathoracic portion of the esophagus were harvested from healthy 8- to 9-week-old university-owned pigs (n = 38) that were euthanized for reasons unrelated to the present study. Each pig was assigned an identification number, and sex, age, and body weight of each pig were recorded. Segments were harvested within 60 minutes after the pigs were euthanized. Each segment was at least 8 cm in length, and the cranial end of each segment was marked with a 1-cm slit made with Metzenbaum scissors. Each esophageal segment was placed in a plastic baga filled with approximately 500 mL of lactated Ringer solution; bags were sealed and chilled overnight at 4°C. The time between harvest (the moment harvesting began) until testing (the moment a sample was removed from the refrigerator for testing) was recorded.
Procedures
Before testing was conducted, each segment of the esophagus was rinsed with tap water to remove ingesta from the lumen. Each segment was manually stretched in a longitudinal direction and dilated in a transverse direction by passage of a 1.5 × 0.75 - cm smooth cylindrical plastic objectb to alleviate muscle contraction resulting from storage in the refrigerator. The plastic object was gently passed in a cranial to caudal direction until it exited the esophageal segment. After dilation was completed, the plastic object was reinserted into the cranial end of the esophageal lumen and positioned in the central portion of the esophageal segment. The ends of each segment were occluded with Rochester Pean forceps mounted to ring stands. The occluded ends of each esophageal segment were placed 7 cm apart in a manner that maintained moderate tension on the esophageal segment (Figure 1). Moderate tension was subjectively determined by an investigator (APS) as the amount of tension needed to suspend the segment such that there was no slack and no excessive stretching of the segment.

Photographs of the testing apparatus used to evaluate closure of an esophagotomy in porcine cadaver tissues. In all images, cranial is to the left. A—Segment of esophagus with a 1.5 × 0.75-cm smooth cylindrical plastic object in the lumen to aid in dilation. B—Segment of esophagus with a 3-cm incision (cranial and caudal extents of the incision are indicted with asterisks). Notice that the plastic object has been removed. The scale on the scalpel handle is in centimeters. C—Segment of esophagus with catheters in place and the first layer (mucosa and submucosa) closed with a simple interrupted suture pattern. D—Segment of esophagus with catheters in place. The second layer (muscularis and tunica adventitia) has been closed with a simple interrupted suture pattern.
Citation: American Journal of Veterinary Research 79, 7; 10.2460/ajvr.79.7.787

Photographs of the testing apparatus used to evaluate closure of an esophagotomy in porcine cadaver tissues. In all images, cranial is to the left. A—Segment of esophagus with a 1.5 × 0.75-cm smooth cylindrical plastic object in the lumen to aid in dilation. B—Segment of esophagus with a 3-cm incision (cranial and caudal extents of the incision are indicted with asterisks). Notice that the plastic object has been removed. The scale on the scalpel handle is in centimeters. C—Segment of esophagus with catheters in place and the first layer (mucosa and submucosa) closed with a simple interrupted suture pattern. D—Segment of esophagus with catheters in place. The second layer (muscularis and tunica adventitia) has been closed with a simple interrupted suture pattern.
Citation: American Journal of Veterinary Research 79, 7; 10.2460/ajvr.79.7.787
Photographs of the testing apparatus used to evaluate closure of an esophagotomy in porcine cadaver tissues. In all images, cranial is to the left. A—Segment of esophagus with a 1.5 × 0.75-cm smooth cylindrical plastic object in the lumen to aid in dilation. B—Segment of esophagus with a 3-cm incision (cranial and caudal extents of the incision are indicted with asterisks). Notice that the plastic object has been removed. The scale on the scalpel handle is in centimeters. C—Segment of esophagus with catheters in place and the first layer (mucosa and submucosa) closed with a simple interrupted suture pattern. D—Segment of esophagus with catheters in place. The second layer (muscularis and tunica adventitia) has been closed with a simple interrupted suture pattern.
Citation: American Journal of Veterinary Research 79, 7; 10.2460/ajvr.79.7.787
The ring stands were positioned so that the cranial end was oriented to the left of the surgeon. A full-thickness incision was made directly over the plastic object with a No. 15 scalpel blade. The incision was extended cranially and caudally to a length of 3 cm with Metzenbaum scissors (Figure 1). After the incision was made, the plastic object was removed and two 18-gauge IV catheters were inserted into the lumen through the wall of the esophagus. One catheter was inserted into the lumen at the cranial end of the esophageal segment and connected to a 60-mL syringe filled with lactated Ringer solution; the syringe was connected to a syringe pump.c The other catheter was inserted into the lumen at the caudal end of the esophageal segment and connected to a pressure transducer, transducer amplifier,d and pressure monitoring system.e The fluid lines connected to each catheter were secured to the adjacent ring stands to prevent the catheters from becoming dislodged from the esophageal segment.
All incisions were closed with 4-0 polydioxanone suture with a swaged small half-circle taper needle.f Esophagotomies were closed with a double-layer simple interrupted pattern or a double-layer simple continuous pattern. Each suture bite was placed 2 mm from the cut edge of the incision; sutures were placed at intervals of 2 to 3 mm (Figure 1). For the closure of the inner layer (mucosa and submucosa), knots were placed in the lumen of the esophagus. For the closure of the outer layer (muscularis and tunica adventitia), knots were placed on the outside of the tunica adventitia. For the simple interrupted pattern, each suture was tied with 2 square knots. For the simple continuous pattern, each suture was tied with 3 square knots. The amount of time required for closure was recorded as the interval from the first pass of suture in the inner layer to tying of the last square knot of the final suture in the outer layer.
Testing of each segment was conducted. The first esophageal segment tested was a simple interrupted pattern, and the second esophageal segment tested was a simple continuous pattern. Testing of segments was alternated between suture patterns until all esophagi were tested. The order in which segments were tested within a suture pattern was determined by use of a random number generator.
After the incision was closed, lactated Ringer solution with green food coloringg was injected through the cranial catheter into the lumen of the esophagus at a rate of 100 mL/h. Leak pressure was defined as the pressure recorded at the caudal catheter when a drop of fluid began to accumulate on the outside of the esophagus and the pressure reached a plateau on the monitor. The total volume infused was recorded, and the time to leakage was calculated by use of the volume infused and the infusion rate. Bursting wall tension was calculated as P√(V/πL), where P is leak pressure, V is volume infused, and L is length of the segment.
After testing was completed, each esophageal segment was incised longitudinally on the side opposite the sutured incision. Segments were inspected for defects of the luminal surface, including mucosal perforations caused by passage of the plastic object, mucosal lacerations created during the initial incision, or defects in the incisional closure.
Statistical analysis
Data were assessed for normality with the Shapiro-Wilk method and equality of variances with the Brown-Forsythe method. The dependent variables including amount of time from harvest to refrigeration, duration of storage, volume infused, duration of infusion, and amount of time required to complete the closure met the assumptions of normality and equality of variances and were compared between suture patterns by use of a t test. Pig body weight, esophageal segment length, incision length, leak pressure, and bursting wall tension were not normally distributed and were compared between suture patterns with the Mann-Whitney rank sum test. All analyses were conducted with commercial software,h and significance was set at P < 0.05 for all analyses.
Results
Of the 38 harvested esophageal segments, 3 were excluded because of damage during harvesting or because they were too short. An additional 7 segments (3 with a simple interrupted pattern and 4 with a simple continuous pattern) were excluded after testing because of technical or procedural issues that did not conform to the experimental methods; this included unburied knots in the inner layer (3 segments with a simple interrupted pattern and 2 segments with a simple continuous pattern) or inappropriate placement of catheters (2 segments with a simple continuous pattern). Consequently, data collected for 28 esophageal segments (15 with a simple interrupted pattern and 13 with a simple continuous pattern) were analyzed.
Values for several variables did not differ significantly between suture patterns. Median pig body weight did not differ significantly (P = 0.39) between the simple interrupted pattern (14.0 kg; range, 12.5 to 16.7 kg) and simple continuous pattern (15.2 kg; range, 11.4 to 19.6 kg). Median esophageal segment length did not differ significantly (P = 0.46) between the simple interrupted pattern (7.0 cm; range, 6.9 to 7.3 cm) and simple continuous pattern (7.0 cm; range, 7.0 to 7.2 cm). Mean ± SD time from harvest until refrigeration did not differ significantly (P = 0.10) between the simple interrupted pattern (81 ± 32 minutes) and simple continuous pattern (102 ± 32 minutes). Mean duration of storage did not differ significantly (P = 0.88) between the simple interrupted pattern (19.08 ± 2.22 hours) and simple continuous pattern (18.93 ± 2.78 hours). Median incision length did not differ significantly (P = 0.64) between the simple interrupted pattern (3.0 cm; range, 3.0 to 3.2 cm) and simple continuous pattern (3.0 cm; range, 2.9 to 3.3 cm).
Simple interrupted closure required significantly (P = 0.01) more time to complete than did simple continuous closure (Figure 2). Mean ± SD closure time was 19.2 ± 2.0 minutes for the simple interrupted pattern and 14.7 ± 1.5 minutes for the simple continuous pattern.

Box-and-whisker plots of closure time for simple interrupted (n = 15) and simple continuous (13) suture patterns used for closure of an esophagotomy in cadaveric porcine tissues. Each box represents the middle 2 quartiles of the distribution, the horizontal line represents the median, and circles represent outliers. Median values differ significantly (P = 0.01) between suture patterns.
Citation: American Journal of Veterinary Research 79, 7; 10.2460/ajvr.79.7.787

Box-and-whisker plots of closure time for simple interrupted (n = 15) and simple continuous (13) suture patterns used for closure of an esophagotomy in cadaveric porcine tissues. Each box represents the middle 2 quartiles of the distribution, the horizontal line represents the median, and circles represent outliers. Median values differ significantly (P = 0.01) between suture patterns.
Citation: American Journal of Veterinary Research 79, 7; 10.2460/ajvr.79.7.787
Box-and-whisker plots of closure time for simple interrupted (n = 15) and simple continuous (13) suture patterns used for closure of an esophagotomy in cadaveric porcine tissues. Each box represents the middle 2 quartiles of the distribution, the horizontal line represents the median, and circles represent outliers. Median values differ significantly (P = 0.01) between suture patterns.
Citation: American Journal of Veterinary Research 79, 7; 10.2460/ajvr.79.7.787
Median leak pressure was significantly (P = 0.03) lower for the simple interrupted pattern (16.0 mm Hg; range, 5.4 to 54.9 mm Hg) than the simple continuous pattern (38.7 mm Hg; range, 11.3 to 81.9 mm Hg; Figure 3). Mean ± SD total volume infused was significantly (P = 0.008) lower for the simple interrupted pattern (1.97 ± 0.73 mL) than the simple continuous pattern (2.90 ± 0.96 mL). Mean time to leakage was significantly (P = 0.008) less for the simple interrupted pattern (70.7 ± 26.3 seconds) than the simple continuous pattern (104.1 ± 34.6 seconds). Median bursting wall tension was significantly (P = 0.024) lower for the simple interrupted pattern (0.63 × 105 dynes/cm; range, 0.16 × 105 dynes/cm to 2.89 × 105 dynes/cm) than the simple continuous pattern (1.79 × 105 dynes/cm; range, 0.44 × 105 dynes/cm to 4.70 × 105 dynes/cm).

Box-and whisker-plots of leak pressure for simple interrupted (n = 15) and simple continuous (13) suture patterns used for closure of an esophagotomy in cadaveric porcine tissues. Median value differs significantly (P = 0.03) between suture patterns. See Figure 2 for remainder of key.
Citation: American Journal of Veterinary Research 79, 7; 10.2460/ajvr.79.7.787

Box-and whisker-plots of leak pressure for simple interrupted (n = 15) and simple continuous (13) suture patterns used for closure of an esophagotomy in cadaveric porcine tissues. Median value differs significantly (P = 0.03) between suture patterns. See Figure 2 for remainder of key.
Citation: American Journal of Veterinary Research 79, 7; 10.2460/ajvr.79.7.787
Box-and whisker-plots of leak pressure for simple interrupted (n = 15) and simple continuous (13) suture patterns used for closure of an esophagotomy in cadaveric porcine tissues. Median value differs significantly (P = 0.03) between suture patterns. See Figure 2 for remainder of key.
Citation: American Journal of Veterinary Research 79, 7; 10.2460/ajvr.79.7.787
Discussion
The difference in closure time between suture patterns in the present study coincided with the previous finding that simple continuous patterns could be completed more rapidly than simple interrupted patterns.1 Because simple continuous patterns have fewer knots than simple interrupted patterns, the simple continuous closure was expected to be completed more rapidly than was the simple interrupted closure.
The difference in leak pressure and bursting wall tension between suture patterns was contrary to our hypothesis, which stated that leak pressure would not differ significantly between suture patterns. However, a significantly higher leak pressure was detected for the simple continuous pattern. The higher leak pressure may have been attributable to a tighter seal formed with simple continuous closure than with simple interrupted closure. During testing, all leakage occurred at the incision. Gaps between suture bites of interrupted patterns may be more likely to allow leakage of fluid because there is no suture spanning the gap, whereas there is always some suture spanning the gap in a continuous suture pattern.
The difference in total volume infused and time to leakage between suture patterns likely was a consequence of the difference in leakage pressure. As the pressure needed to cause leakage increased, so did the volume needed to achieve that pressure as well as the time necessary to infuse that volume.
In the present study, 5 samples were excluded because of improper knot placement. In clinical practice, it is likely that such errors will occur and may interfere with tissue apposition and result in a lower leakage pressure.
Measurements of bursting wall tension in double-layer simple interrupted esophagotomy closures (3.5 × 105 dynes/cm) reported in another study6 are not within the range detected in the present study (0.16 × 105 dynes/cm to 2.89 × 105 dynes/cm). This likely was a result of differences in study design, including the species (canine vs porcine), segment of esophagus (cervical vs thoracic), set-up of the testing apparatus (submerged in saline [0.9% NaCl] solution vs suspended between forceps), method of fluid infusion (intraluminal fenestrated catheter vs transmural IV catheter), and status of the animal when the suturing was performed (living vs cadaver).
Cadaveric tissues were used in the present study; thus, it was not possible to assess the healing response of the tissue. It is likely that the inflammation that occurs in tissues of live animals in the immediate postoperative phase of healing will cause swelling and thus improve the seal along the incision. Additionally, it is possible that different suture patterns may result in differing degrees of mucosal apposition and thus alter esophageal healing. Further studies with live animals may be helpful in assessing differences in incisional healing between suture patterns.
Motion of the head and neck has been proposed as a reason for the high incidence of postoperative complications after esophageal surgeries.1 Because of the use of immobile, intrathoracic segments of cadaveric esophagus in the present study, the influence of motion on leakage pressure relative to suture pattern could not be addressed. Future studies with cervical portions of the esophagus in live animals or techniques that involve portions of the cervical esophagus may be useful in investigating the role of motion on incision integrity.
The study reported here was performed with porcine esophagi; therefore, results may not directly represent those for esophageal surgery in cats and dogs. Although there were no significant differences between suture pattern groups regarding age and body weight in the present study, it is possible that proportional differences in the size of the esophagus of baby pigs relative to that of adult pigs may influence the comparison among swine of other ages. Additionally, there are differences in the anatomic structure of the esophagus across species, such as the composition of skeletal and smooth muscle fibers in the muscularis layer and the degree of keratinization of the mucosal layer.7–10 However, these differences are much less pronounced in the cranial portion of the thoracic esophagus,7–10 which was the portion of esophagus used in the present study. Therefore, it would be anticipated that results obtained from the porcine specimens of the present study likely can be applicable to other species. However, additional studies with canine or feline cadaveric esophagi would be needed to confirm this assumption. To the authors' knowledge, the study reported here was the first in which porcine esophagi were used to assess leakage pressure.
The simple continuous pattern could be performed significantly more rapidly than the simple interrupted pattern while maintaining a better immediate seal as indicated by a significantly higher median leak pressure. These data provided evidence to suggest that double-layer simple continuous closure patterns may be superior to simple interrupted closure patterns for esophagotomy. Further studies in live animals will be necessary to reach definitive conclusions regarding the optimal suture pattern to use for closure of an esophagotomy.
Acknowledgments
Data collection and analysis were performed at the University of Missouri.
Supported by the Boehringer-Ingelheim Veterinary Scholars Program and the University of Missouri Veterinary Research Scholars Program.
Presented as an abstract and poster at the Boehringer-Ingelheim Veterinary Scholars Symposium, Bethesda, Md, August 2017.
Boehringer-Ingelheim played no role in the design of this study.
The authors declare that there were no conflicts of interest.
Footnotes
Ziploc plastic storage bag, SC Johnson & Son Inc, Racine, Wis.
Male-end adapter cap on a secondary IV infusion set, list No. 14230-28, Hospira Inc, Lake Forest, Ill.
Medfusion syringe pump model 3500, version 3.0.6, Smiths Medical, Saint Paul, Minn.
ETH 400 transducer amplifier, CB Sciences Inc, Dover, NH.
PowerLab/4SP, ADInstruments Inc, Colorado Springs, Colo.
4-0 PDS II suture violet 27-inch on an SH taper needle, Ethicon Inc, Sommerville, NJ.
Food color and egg dye, Schnuck Markets, St Louis, Mo.
SigmaPlot, version 13.0, Systat Software Inc, San Rafael, Calif.
References
1. Sutton JS, Culp WTN, Scotti K, et al. Perioperative morbidity and outcome of esophageal surgery in dogs and cats: 72 cases (1993–2013). J Am Vet Med Assoc 2016;249:787–793.
2. Fossum TW, Hedlund CS, Hulse DA, et al. Surgery of the esophagus. In: Small animal surgery. 2nd ed. Maryland Heights, Mo: Mosby, 2002;307–337.
3. Flanders JA. Problems and complications associated with esophageal surgery. Probl Vet Med 1989;1:183–194.
4. Tobias KM, Johnston SA. Esophagus. In: Veterinary surgery: small animal. Philadelphia: Saunders, 2012;1461–1483.
5. Griffon D, Hamaide A. Esophagoscopy and esophageal surgery. In: Complications in small animal surgery. Hoboken, NJ: Wiley-Blackwell, 2016;319–322.
6. Oakes MG, Hosgood G, Snider TG, et al. Esophagotomy closure in the dog: a comparison of a double-layer appositional and two single-layer appositional techniques. Vet Surg 1993;22:451–456.
7. Dyce KM, Sack WO, Wensing CJG. General anatomy: the digestive apparatus. In: Textbook of veterinary anatomy. 4th ed. St Louis: Saunders-Elsevier, 2010;100–147.
8. Dyce KM, Sack WO, Wensing CJG. Dogs and cats: the esophagus, trachea, and thymus. In: Textbook of veterinary anatomy. 4th ed. St Louis: Saunders-Elsevier, 2010;430.
9. Dyce KM, Sack WO, Wensing CJG. Pigs: the ventral aspect of the neck. In: Textbook of veterinary anatomy. 4th ed. St Louis: Saunders-Elsevier, 2010;759.
10. Bacha WJ, Bacha LM. Digestive system: esophagus. In: Color atlas of veterinary histology. 3rd ed. Hoboken, NJ: Wiley-Blackwell, 2012;140.