Relationships between a proprietary index, bispectral index, and hemodynamic variables as a means for evaluating depth of anesthesia in dogs anesthetized with sevoflurane

María S. Carrasco-Jiménez Department of Anesthesiology, Medical School, Hospital Universitario de Puerto Real, Cádiz University, Cadiz, Spain.

Search for other papers by María S. Carrasco-Jiménez in
Current site
Google Scholar
PubMed
Close
 MD, PhD
,
María F. Martín Cancho Minimally Invasive Surgery Centre, Avda/Universidad s/n, 10071 Cáceres, Spain.

Search for other papers by María F. Martín Cancho in
Current site
Google Scholar
PubMed
Close
 PD, PhD
,
Juan R. Lima Minimally Invasive Surgery Centre, Avda/Universidad s/n, 10071 Cáceres, Spain.

Search for other papers by Juan R. Lima in
Current site
Google Scholar
PubMed
Close
 DVM
,
Verónica Crisóstomo Minimally Invasive Surgery Centre, Avda/Universidad s/n, 10071 Cáceres, Spain.

Search for other papers by Verónica Crisóstomo in
Current site
Google Scholar
PubMed
Close
 DVM
,
Jesús Usón-Gargallo Minimally Invasive Surgery Centre, Avda/Universidad s/n, 10071 Cáceres, Spain.

Search for other papers by Jesús Usón-Gargallo in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
, and
Luis J. Ezquerra Surgery Department, College of Veterinary Medicine, University of Extremadura, Cáceres, Spain.

Search for other papers by Luis J. Ezquerra in
Current site
Google Scholar
PubMed
Close
 DVM, PhD

Abstract

Objective—To evaluate relationships among various techniques for monitoring anesthetic depth in sevoflurane-anesthetized dogs undergoing orthopedic surgery.

Animals—10 dogs.

Procedure—Dogs were medicated with acepromazine (0.05 mg/kg, IM), buprenorphine (0.01 mg/kg, IM), and atropine (0.04 mg/kg, IM). Anesthesia was induced and maintained with sevoflurane. Cardiovascular and respiratory responses were monitored. Anesthetic depth was monitored by use of the bispectral index (BIS), and a proprietary index was used to monitor activity of the autonomic nervous system.

Results—A significant decrease in BIS was seen after induction but concurrent changes were not observed for the other techniques. The proprietary index increased significantly after intubation, but no changes were seen for the other techniques. No significant changes were detected during incision or when higher nociceptive stimuli were applied. We did not identify a correlation between BIS and the proprietary index, the proprietary index and hemodynamic variables, or the BIS and hemodynamic variables during induction and maintenance. A significant increase in the proprietary index and BIS was detected at the time of resumption of reflexes. During anesthetic recovery, a correlation was found between the proprietary index and BIS but not between hemodynamic variables and the other techniques.

Conclusions and Clinical Relevance—A significant increase in the proprietary index, but not the BIS or hemodynamic variables, was detected during intubation. Anesthetic induction with sevoflurane did not prevent the sympathetic stimulus attributable to tracheal intubation. Monitoring of hemodynamic variables does not provide sufficient information to allow clinicians to evaluate stress during anesthetic recovery. (Am J Vet Res 2004;65:1128–1135)

Abstract

Objective—To evaluate relationships among various techniques for monitoring anesthetic depth in sevoflurane-anesthetized dogs undergoing orthopedic surgery.

Animals—10 dogs.

Procedure—Dogs were medicated with acepromazine (0.05 mg/kg, IM), buprenorphine (0.01 mg/kg, IM), and atropine (0.04 mg/kg, IM). Anesthesia was induced and maintained with sevoflurane. Cardiovascular and respiratory responses were monitored. Anesthetic depth was monitored by use of the bispectral index (BIS), and a proprietary index was used to monitor activity of the autonomic nervous system.

Results—A significant decrease in BIS was seen after induction but concurrent changes were not observed for the other techniques. The proprietary index increased significantly after intubation, but no changes were seen for the other techniques. No significant changes were detected during incision or when higher nociceptive stimuli were applied. We did not identify a correlation between BIS and the proprietary index, the proprietary index and hemodynamic variables, or the BIS and hemodynamic variables during induction and maintenance. A significant increase in the proprietary index and BIS was detected at the time of resumption of reflexes. During anesthetic recovery, a correlation was found between the proprietary index and BIS but not between hemodynamic variables and the other techniques.

Conclusions and Clinical Relevance—A significant increase in the proprietary index, but not the BIS or hemodynamic variables, was detected during intubation. Anesthetic induction with sevoflurane did not prevent the sympathetic stimulus attributable to tracheal intubation. Monitoring of hemodynamic variables does not provide sufficient information to allow clinicians to evaluate stress during anesthetic recovery. (Am J Vet Res 2004;65:1128–1135)