Comparison of the use of regulatory assays and high-performance liquid chromatography for detection of residues of ceftiofur sodium metabolites in tissue specimens of culled dairy cattle

Michael A. PayneEnvironmental Toxicology Extension, University of California, Davis, CA 95616.

Search for other papers by Michael A. Payne in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
,
Scott E. WetzlichEnvironmental Toxicology Extension, University of California, Davis, CA 95616.

Search for other papers by Scott E. Wetzlich in
Current site
Google Scholar
PubMed
Close
 BS
,
Edward J. RobbPfizer Animal Health, 7000 Portage Rd, Kalamazoo, MI 49001.

Search for other papers by Edward J. Robb in
Current site
Google Scholar
PubMed
Close
 DVM
,
Scott A. BrownPfizer Animal Health, 7000 Portage Rd, Kalamazoo, MI 49001.

Search for other papers by Scott A. Brown in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
,
Ian A. GardnerDepartment of Population Health and Reproduction, School of Veterinary Medicine, University of California, Davis, CA 95616.

Search for other papers by Ian A. Gardner in
Current site
Google Scholar
PubMed
Close
 BVSc, PhD, MPVM
,
James S. CullorDepartment of Medicine and Epidemiology, School of Veterinary Medicine, University of California, Davis, CA 95616.

Search for other papers by James S. Cullor in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
, and
Arthur L. CraigmillEnvironmental Toxicology Extension, University of California, Davis, CA 95616.

Search for other papers by Arthur L. Craigmill in
Current site
Google Scholar
PubMed
Close
 PhD
View More View Less

Abstract

Objective—To compare the results of regulatory screening and confirmation assays with those of highperformance liquid chromatography (HPLC) in the detection of ceftiofur metabolites in the tissues of culled dairy cattle.

Animals—17 lactating Holstein dairy cows.

Procedure—Daily IM injections of ceftiofur sodium were administered at a dose of 2.2 mg of ceftiofur equivalents/kg (n = 6) or 1.0 mg of ceftiofur equivalents/kg (10) for 5 days. Following withdrawal times of 12 hours (high-dose ceftiofur) and either 5 or 10 days (low-dose ceftiofur), cows were slaughtered and liver, kidney, and diaphragmatic muscle specimens were harvested and analyzed by HPLC and standard regulatory methods that included the following assays: the swab test on premises, the fast antimicrobial screen test, the calf antibiotic and sulfa test, and the 7-plate bioassay confirmation test.

Results—In all tissue specimens, residues of ceftiofur and desfuroylceftiofur-related metabolites, as measured by HPLC, were less than regulatory tolerance, as defined by the FDA. False-positive screening assay results were more likely for tissue specimens that had been frozen for shipment to a federal laboratory, compared with fresh tissue specimens that were assayed at the slaughter establishment (23% vs 3% false-positive results, respectively).

Conclusions and Clinical Relevance—The observation that fresh tissues had negative results on screening assays, whereas subsets of the same tissue specimens had false-positive results on screening assays following freezing, suggests that freezing and thawing interferes with microbial inhibition-based regulatory screening assays. (Am J Vet Res 2004;65:1730–1733)

Abstract

Objective—To compare the results of regulatory screening and confirmation assays with those of highperformance liquid chromatography (HPLC) in the detection of ceftiofur metabolites in the tissues of culled dairy cattle.

Animals—17 lactating Holstein dairy cows.

Procedure—Daily IM injections of ceftiofur sodium were administered at a dose of 2.2 mg of ceftiofur equivalents/kg (n = 6) or 1.0 mg of ceftiofur equivalents/kg (10) for 5 days. Following withdrawal times of 12 hours (high-dose ceftiofur) and either 5 or 10 days (low-dose ceftiofur), cows were slaughtered and liver, kidney, and diaphragmatic muscle specimens were harvested and analyzed by HPLC and standard regulatory methods that included the following assays: the swab test on premises, the fast antimicrobial screen test, the calf antibiotic and sulfa test, and the 7-plate bioassay confirmation test.

Results—In all tissue specimens, residues of ceftiofur and desfuroylceftiofur-related metabolites, as measured by HPLC, were less than regulatory tolerance, as defined by the FDA. False-positive screening assay results were more likely for tissue specimens that had been frozen for shipment to a federal laboratory, compared with fresh tissue specimens that were assayed at the slaughter establishment (23% vs 3% false-positive results, respectively).

Conclusions and Clinical Relevance—The observation that fresh tissues had negative results on screening assays, whereas subsets of the same tissue specimens had false-positive results on screening assays following freezing, suggests that freezing and thawing interferes with microbial inhibition-based regulatory screening assays. (Am J Vet Res 2004;65:1730–1733)

Advertisement