Assessment of the accuracy of computed tomography for measurement of normal equine pituitary glands

Tori L. McKlveen Department of Small Animal Clinical Sciences, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA 24061-0442.

Search for other papers by Tori L. McKlveen in
Current site
Google Scholar
PubMed
Close
 DVM, MS
,
Jeryl C. Jones Department of Small Animal Clinical Sciences, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA 24061-0442.

Search for other papers by Jeryl C. Jones in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
,
D. Phillip Sponenberg Department of Biomedical Sciences and Pathobiology, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA 24061-0442.

Search for other papers by D. Phillip Sponenberg in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
,
Kent Scarratt Department of Large Animal Clinical Sciences, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA 24061-0442.

Search for other papers by Kent Scarratt in
Current site
Google Scholar
PubMed
Close
 DVM
,
Daniel L. Ward Office of Research and Graduate Studies, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA 24061-0442.

Search for other papers by Daniel L. Ward in
Current site
Google Scholar
PubMed
Close
 PhD
, and
Charles H. Aardema Jr Department of Biomedical Sciences and Pathobiology, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA 24061-0442.

Search for other papers by Charles H. Aardema Jr in
Current site
Google Scholar
PubMed
Close
 BS

Abstract

Objective—To describe the anatomic features of the pituitary gland region in horses via computed tomography (CT) and determine the accuracy of CT for estimating normal equine pituitary gland dimensions.

Animals—25 adult horses with no clinical signs of pituitary disease.

Procedure—Transverse CT images and gross transverse tissue sections were compared in 2 horses. Contrast-enhanced CT of the pituitary gland region was performed postmortem in 23 horses with 4 slice thickness and interval settings (10-mm contiguous or overlapping slices and 4-mm contiguous or overlapping slices). Gross and CT estimates of pituitary gland dimensions were compared via ANOVA. Accuracy of CT estimates was calculated with gross pituitary gland measurements as the known value.

Results—Pituitary glands were located between the temporomandibular joints and had contrast enhancement. Mean gross dimensions were length, 2.11 cm; width, 2.16 cm; height, 0.98 cm; and volume, 2.66 cm3. Gross measurements and CT estimates of pituitary gland length from 10-mm contiguous and overlapping slices did not differ. Gross measurements and CT estimates of pituitary gland width from 4-mm contiguous and overlapping slices did not differ. Estimates of height and volume from all CT techniques differed from gross measurements. Accuracies for CT estimates were length, 88 to 99%; width, 81 to 92%; height, 58 to 71%; and volume, 43 to 55%.

Conclusions and Clinical Relevance—Accuracy of estimates of pituitary gland dimension in horses varied with CT scanning technique; via CT, estimates of length and width of glands were more accurate than estimates of height or volume. (Am J Vet Res 2003;64:1387–1394)

Abstract

Objective—To describe the anatomic features of the pituitary gland region in horses via computed tomography (CT) and determine the accuracy of CT for estimating normal equine pituitary gland dimensions.

Animals—25 adult horses with no clinical signs of pituitary disease.

Procedure—Transverse CT images and gross transverse tissue sections were compared in 2 horses. Contrast-enhanced CT of the pituitary gland region was performed postmortem in 23 horses with 4 slice thickness and interval settings (10-mm contiguous or overlapping slices and 4-mm contiguous or overlapping slices). Gross and CT estimates of pituitary gland dimensions were compared via ANOVA. Accuracy of CT estimates was calculated with gross pituitary gland measurements as the known value.

Results—Pituitary glands were located between the temporomandibular joints and had contrast enhancement. Mean gross dimensions were length, 2.11 cm; width, 2.16 cm; height, 0.98 cm; and volume, 2.66 cm3. Gross measurements and CT estimates of pituitary gland length from 10-mm contiguous and overlapping slices did not differ. Gross measurements and CT estimates of pituitary gland width from 4-mm contiguous and overlapping slices did not differ. Estimates of height and volume from all CT techniques differed from gross measurements. Accuracies for CT estimates were length, 88 to 99%; width, 81 to 92%; height, 58 to 71%; and volume, 43 to 55%.

Conclusions and Clinical Relevance—Accuracy of estimates of pituitary gland dimension in horses varied with CT scanning technique; via CT, estimates of length and width of glands were more accurate than estimates of height or volume. (Am J Vet Res 2003;64:1387–1394)

All Time Past Year Past 30 Days
Abstract Views 33 0 0
Full Text Views 1967 1838 308
PDF Downloads 183 90 10
Advertisement