Development of a technique for the in vivo assessment of flatulence in dogs

Stella B. Collins Waltham Centre for Pet Nutrition, Freeby Ln, Walthamon-the-Wolds, Melton Mowbray, Leicestershire, LE14 4RT, UK

Search for other papers by Stella B. Collins in
Current site
Google Scholar
PubMed
Close
 BSc
,
Gerardo Perez-Camargo Waltham Centre for Pet Nutrition, Freeby Ln, Walthamon-the-Wolds, Melton Mowbray, Leicestershire, LE14 4RT, UK

Search for other papers by Gerardo Perez-Camargo in
Current site
Google Scholar
PubMed
Close
 Ldo Vet, PhD
,
George Gettinby Department of Statistics and Modeling Science, University of Strathclyde, Glasgow G1 1XH, UK

Search for other papers by George Gettinby in
Current site
Google Scholar
PubMed
Close
 PhD
,
Richard F. Butterwick Waltham Centre for Pet Nutrition, Freeby Ln, Walthamon-the-Wolds, Melton Mowbray, Leicestershire, LE14 4RT, UK

Search for other papers by Richard F. Butterwick in
Current site
Google Scholar
PubMed
Close
 PhD
,
Roger M. Batt Waltham Centre for Pet Nutrition, Freeby Ln, Walthamon-the-Wolds, Melton Mowbray, Leicestershire, LE14 4RT, UK

Search for other papers by Roger M. Batt in
Current site
Google Scholar
PubMed
Close
 BVSc, PhD
, and
Catriona J. Giffard Waltham Centre for Pet Nutrition, Freeby Ln, Walthamon-the-Wolds, Melton Mowbray, Leicestershire, LE14 4RT, UK.
Present address is Uncle Bens Australia, Kelly St, Wodonga, VIC 3690, Australia.

Search for other papers by Catriona J. Giffard in
Current site
Google Scholar
PubMed
Close
 DPhil

Abstract

Objective—To develop a noninvasive method for the in vivo assessment of flatulence in dogs.

Animals—8 adult dogs.

Procedure—Rectal gases were collected via a perforated tube held close to each dog's anus and attached to a monitoring pump fitted with a sensor that recorded hydrogen sulfide concentrations every 20 seconds. Patterns of flatulence were monitored for 14 hours after feeding on 4 days, and within- and between-dog variation was assessed over 4 hours on 4 consecutive days. Rate of hydrogen sulfide production (flatulence index) and frequency and number of emissions were evaluated as potential indicators of flatus characteristics. An odor judge assigned an odor rating to each flatulence episode, and the relationship between that rating and hydrogen sulfide concentration was determined.

Results—Flatulence patterns varied within and between dogs. Variation was most pronounced for flatulence index; mean coefficients of variance within dogs over time and between dogs on each day were 75 and 103%, respectively. Flatus with hydrogen sulfide concentrations > 1 parts per million could be detected by the odor judge, and severity of malodor was highly correlated with hydrogen sulfide concentration. Odor ratings were accurately predicted by use of the equation 1.51 × hydrogen sulfide concentration0.28.

Conclusions and Clinical Relevance—The technique described in this report appears to provide sensitive, reliable, and relevant data and will enable further studies of the factors that influence flatulence in dogs. Use of this technique also has the potential to aid in investigations of colonic physiology and pathology. (Am J Vet Res 2001;62:1014–1019).

Abstract

Objective—To develop a noninvasive method for the in vivo assessment of flatulence in dogs.

Animals—8 adult dogs.

Procedure—Rectal gases were collected via a perforated tube held close to each dog's anus and attached to a monitoring pump fitted with a sensor that recorded hydrogen sulfide concentrations every 20 seconds. Patterns of flatulence were monitored for 14 hours after feeding on 4 days, and within- and between-dog variation was assessed over 4 hours on 4 consecutive days. Rate of hydrogen sulfide production (flatulence index) and frequency and number of emissions were evaluated as potential indicators of flatus characteristics. An odor judge assigned an odor rating to each flatulence episode, and the relationship between that rating and hydrogen sulfide concentration was determined.

Results—Flatulence patterns varied within and between dogs. Variation was most pronounced for flatulence index; mean coefficients of variance within dogs over time and between dogs on each day were 75 and 103%, respectively. Flatus with hydrogen sulfide concentrations > 1 parts per million could be detected by the odor judge, and severity of malodor was highly correlated with hydrogen sulfide concentration. Odor ratings were accurately predicted by use of the equation 1.51 × hydrogen sulfide concentration0.28.

Conclusions and Clinical Relevance—The technique described in this report appears to provide sensitive, reliable, and relevant data and will enable further studies of the factors that influence flatulence in dogs. Use of this technique also has the potential to aid in investigations of colonic physiology and pathology. (Am J Vet Res 2001;62:1014–1019).

All Time Past Year Past 30 Days
Abstract Views 76 0 0
Full Text Views 1245 1008 224
PDF Downloads 266 151 11