Vascular and transsynovial forces of the isolated stationary equine joint

Alicia L. Bertone From the Orthopedic (Bertone, Hardy, Simmons) and Cardiovascular (Muir) Research Laboratories, Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, OH 43210.

Search for other papers by Alicia L. Bertone in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
,
Joanne Hardy From the Orthopedic (Bertone, Hardy, Simmons) and Cardiovascular (Muir) Research Laboratories, Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, OH 43210.

Search for other papers by Joanne Hardy in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
,
Emily J. Simmons From the Orthopedic (Bertone, Hardy, Simmons) and Cardiovascular (Muir) Research Laboratories, Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, OH 43210.

Search for other papers by Emily J. Simmons in
Current site
Google Scholar
PubMed
Close
 DVM
, and
William W. Muir III From the Orthopedic (Bertone, Hardy, Simmons) and Cardiovascular (Muir) Research Laboratories, Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, OH 43210.

Search for other papers by William W. Muir III in
Current site
Google Scholar
PubMed
Close
 DVM, PhD

Abstract

Objective

To provide quantitative assessment of forces affecting filtration of synovial fluid in response to incremental changes in arterial and venous hemodynamics.

Animals

7 clinically normal adult horses.

Procedure

Using a stationary, isolated metacarpophalangeal joint preparation, blood flow (Qacir), tissue perfusion, arterial pressure (Pacir), venous pressure (Pvcir), transsynovial fluid flow, total vascular resistance, vascular compliance, and tissue compliance were evaluated before and after arterial and venous pressure manipulations. At isogravimetric conditions, pre- and postcapillary resistance and ratios, osmotic reflection coefficient (σd), capillary pressure, net filtration pressure, and transitional microvascular pressure were determined.

Results

Synovial tissue blood flow was similar before, immediately after, and 3.5 hours after joint isolation. The σd for the joint was low, owing to the high oncotic pressure of synovial fluid at filtration-independent states. Transsynovial flow occurred in preference to lymph flow because of the high permeability of synovial tissue (low σd). Synovial fluid production and transfluid flow (synovium weight gain) increased at Pacir > 200 mm of Hg, indicating a threshold phenomenon for synovial filtration. Net filtration pressure > 6 mm of Hg is needed to effect an increase in synovial fluid flow, and pressure of approximately 11 mm of Hg is necessary to increase lymphatic flow. Vascular compliance in the joint was low, but increased markedly with Pvcir. Vascular and tissue compliance increased with increased Pacir. Vascular compliance changes caused by increased arterial pressure were minimal, compared with those caused by increased venous pressure owing to the greater elastance of arteries and the larger muscular arterial wall.

Conclusion

This isolated joint preparation permitted evaluation of codependent hemodynamic, microvascular, and transsynovial flow responses to hemodynamic manipulations. Synovial tissue permeability was markedly affected by increased vascular forces altering filtration pressures toward synovial fluid production. (Am J Vet Res 1998;59:495–503)

Abstract

Objective

To provide quantitative assessment of forces affecting filtration of synovial fluid in response to incremental changes in arterial and venous hemodynamics.

Animals

7 clinically normal adult horses.

Procedure

Using a stationary, isolated metacarpophalangeal joint preparation, blood flow (Qacir), tissue perfusion, arterial pressure (Pacir), venous pressure (Pvcir), transsynovial fluid flow, total vascular resistance, vascular compliance, and tissue compliance were evaluated before and after arterial and venous pressure manipulations. At isogravimetric conditions, pre- and postcapillary resistance and ratios, osmotic reflection coefficient (σd), capillary pressure, net filtration pressure, and transitional microvascular pressure were determined.

Results

Synovial tissue blood flow was similar before, immediately after, and 3.5 hours after joint isolation. The σd for the joint was low, owing to the high oncotic pressure of synovial fluid at filtration-independent states. Transsynovial flow occurred in preference to lymph flow because of the high permeability of synovial tissue (low σd). Synovial fluid production and transfluid flow (synovium weight gain) increased at Pacir > 200 mm of Hg, indicating a threshold phenomenon for synovial filtration. Net filtration pressure > 6 mm of Hg is needed to effect an increase in synovial fluid flow, and pressure of approximately 11 mm of Hg is necessary to increase lymphatic flow. Vascular compliance in the joint was low, but increased markedly with Pvcir. Vascular and tissue compliance increased with increased Pacir. Vascular compliance changes caused by increased arterial pressure were minimal, compared with those caused by increased venous pressure owing to the greater elastance of arteries and the larger muscular arterial wall.

Conclusion

This isolated joint preparation permitted evaluation of codependent hemodynamic, microvascular, and transsynovial flow responses to hemodynamic manipulations. Synovial tissue permeability was markedly affected by increased vascular forces altering filtration pressures toward synovial fluid production. (Am J Vet Res 1998;59:495–503)

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 3881 3862 244
PDF Downloads 50 40 0
Advertisement