Development and validation of a radioimmunoassay for feline trypsin-like immunoreactivity

Jorg M. Steiner From the Gastrointestinal Laboratory, Department of Vctcnnarv Clinical Sciences, Purdue University, West Lafaxeitc, LN 47907.

Search for other papers by Jorg M. Steiner in
Current site
Google Scholar
PubMed
Close
 med vet, Dr med vet
,
Terry L. Medinger From the Gastrointestinal Laboratory, Department of Vctcnnarv Clinical Sciences, Purdue University, West Lafaxeitc, LN 47907.

Search for other papers by Terry L. Medinger in
Current site
Google Scholar
PubMed
Close
 DVM, MS
, and
David A. Williams From the Gastrointestinal Laboratory, Department of Vctcnnarv Clinical Sciences, Purdue University, West Lafaxeitc, LN 47907.

Search for other papers by David A. Williams in
Current site
Google Scholar
PubMed
Close
 MA, Vet MB, PhD

Click on author name to view affiliation information

Abstract

Objective

To develop and validate a radioimmunoassay for feline trypsin-like immunoreactivity (fTLI).

Procedure

A double antibody radioimmunoassay for determination of fTLI was developed, using feline trypsin purified from feline pancreatic tissue, antiserum against feline trypsin raised in New Zealand White rabbits, and a commercially available precipitation solution. This assay was validated by determining detection limit, linearity, accuracy, and intra- and interassay variabilities. A control range was determined from samples of 21 clinically normal cats.

Results

The detection limit for fTLI in this assay was 1.9 μg/L. The linearity of the assay was evaluated by testing dilutional parallelism. Observed/expected values ranged between 95 and 127%. The accuracy of the assay was tested by measuring recovery of added trypsin. Observed/expected values ranged from 99 to 114%. Intra-assay variability ranged between 3.0 and 9.4%, and interassay variability ranged between 4.0 and 8.2%. The control range for serum fTLI was determined to be 17.1 to 48.6 μg/L.

Conclusion

The assay for fTLI described here is sensitive, linear, accurate, precise, and reproducible.

Clinical Relevance

This assay may be of use for the diagnosis of exocrine pancreatic diseases in cats. Preliminary results of such research have been promising, and further clinical studies are in progress. (Am J Vet Res 1996;57:1417–1420)

Abstract

Objective

To develop and validate a radioimmunoassay for feline trypsin-like immunoreactivity (fTLI).

Procedure

A double antibody radioimmunoassay for determination of fTLI was developed, using feline trypsin purified from feline pancreatic tissue, antiserum against feline trypsin raised in New Zealand White rabbits, and a commercially available precipitation solution. This assay was validated by determining detection limit, linearity, accuracy, and intra- and interassay variabilities. A control range was determined from samples of 21 clinically normal cats.

Results

The detection limit for fTLI in this assay was 1.9 μg/L. The linearity of the assay was evaluated by testing dilutional parallelism. Observed/expected values ranged between 95 and 127%. The accuracy of the assay was tested by measuring recovery of added trypsin. Observed/expected values ranged from 99 to 114%. Intra-assay variability ranged between 3.0 and 9.4%, and interassay variability ranged between 4.0 and 8.2%. The control range for serum fTLI was determined to be 17.1 to 48.6 μg/L.

Conclusion

The assay for fTLI described here is sensitive, linear, accurate, precise, and reproducible.

Clinical Relevance

This assay may be of use for the diagnosis of exocrine pancreatic diseases in cats. Preliminary results of such research have been promising, and further clinical studies are in progress. (Am J Vet Res 1996;57:1417–1420)

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 43 43 10
PDF Downloads 32 32 6
Advertisement