Evaluation of Janeway gastrostomy in llamas

Wayne B. Schmotzer From the Veterinary Teaching Hospital (Schmotzer, Huber, Riebold), and College of Veterinary Medicine (Frank, Hollings-head, Smith), Oregon State University, Corvallis, OR 97331.

Search for other papers by Wayne B. Schmotzer in
Current site
Google Scholar
PubMed
Close
 DVM
,
Michael J. Huber From the Veterinary Teaching Hospital (Schmotzer, Huber, Riebold), and College of Veterinary Medicine (Frank, Hollings-head, Smith), Oregon State University, Corvallis, OR 97331.

Search for other papers by Michael J. Huber in
Current site
Google Scholar
PubMed
Close
 DVM, MS
,
Anthony A. Frank From the Veterinary Teaching Hospital (Schmotzer, Huber, Riebold), and College of Veterinary Medicine (Frank, Hollings-head, Smith), Oregon State University, Corvallis, OR 97331.

Search for other papers by Anthony A. Frank in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
,
Thomas W. Riebold From the Veterinary Teaching Hospital (Schmotzer, Huber, Riebold), and College of Veterinary Medicine (Frank, Hollings-head, Smith), Oregon State University, Corvallis, OR 97331.

Search for other papers by Thomas W. Riebold in
Current site
Google Scholar
PubMed
Close
 DVM
,
Nancy C. Hollingshead From the Veterinary Teaching Hospital (Schmotzer, Huber, Riebold), and College of Veterinary Medicine (Frank, Hollings-head, Smith), Oregon State University, Corvallis, OR 97331.

Search for other papers by Nancy C. Hollingshead in
Current site
Google Scholar
PubMed
Close
, and
Bradford B. Smith From the Veterinary Teaching Hospital (Schmotzer, Huber, Riebold), and College of Veterinary Medicine (Frank, Hollings-head, Smith), Oregon State University, Corvallis, OR 97331.

Search for other papers by Bradford B. Smith in
Current site
Google Scholar
PubMed
Close
 DVM, PhD

Summary

To provide long-term gastric fistulas for collection of third-compartment gastric contents, Janeway mucosal tube gastrostomy was performed, using a gastrointestinal stapling instrument, in 6 castrated adult male llamas. Mean operative time (±sem) was 65 ±4.16 minutes. All llamas survived the 6-week study period. Of the 6 llamas, 5 did not have signs of abdominal pain and returned to preoperative food consumption amounts within 36 hours. One llama had mild intermittent signs of abdominal pain daily for 7 days before returning to preoperative amount of food consumption. All gastrostomies leaked small amounts of gastric contents around indwelling 6- to 8-mm cannulas at the skin surface. Gastric contents did not leak when cannulas were dislodged from gastrostomy stomas. Replacement of cannulas was rapid and easy. Gravity-flow sample collection was best accomplished through 8-mm cannulas. Mean (±sem) weight loss was detected in all llamas (15 ± 3 kg) and was associated with frequent nonfeeding and stress of sample collection.

Gross necropsy findings were unremarkable in 5 of 6 llamas. All mucosal tube gastrostomies were patent, and there was no evidence of peritonitis. One llama had a single fibrous adhesion connecting the operative site with the ascending colon. Histologically, small (2.5- to 15-mm diameter) partial-thickness mucosal erosions identified at the tube gastrostomy-gastric wall junctions may have been associated with indwelling gastric cannulas. The Janeway gastrostomy was generally well tolerated in the llamas and should be considered as a useful long-term fistulation technique.

Summary

To provide long-term gastric fistulas for collection of third-compartment gastric contents, Janeway mucosal tube gastrostomy was performed, using a gastrointestinal stapling instrument, in 6 castrated adult male llamas. Mean operative time (±sem) was 65 ±4.16 minutes. All llamas survived the 6-week study period. Of the 6 llamas, 5 did not have signs of abdominal pain and returned to preoperative food consumption amounts within 36 hours. One llama had mild intermittent signs of abdominal pain daily for 7 days before returning to preoperative amount of food consumption. All gastrostomies leaked small amounts of gastric contents around indwelling 6- to 8-mm cannulas at the skin surface. Gastric contents did not leak when cannulas were dislodged from gastrostomy stomas. Replacement of cannulas was rapid and easy. Gravity-flow sample collection was best accomplished through 8-mm cannulas. Mean (±sem) weight loss was detected in all llamas (15 ± 3 kg) and was associated with frequent nonfeeding and stress of sample collection.

Gross necropsy findings were unremarkable in 5 of 6 llamas. All mucosal tube gastrostomies were patent, and there was no evidence of peritonitis. One llama had a single fibrous adhesion connecting the operative site with the ascending colon. Histologically, small (2.5- to 15-mm diameter) partial-thickness mucosal erosions identified at the tube gastrostomy-gastric wall junctions may have been associated with indwelling gastric cannulas. The Janeway gastrostomy was generally well tolerated in the llamas and should be considered as a useful long-term fistulation technique.

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 4035 4035 774
PDF Downloads 46 46 3
Advertisement