Search Results
You are looking at 1 - 3 of 3 items for
- Author or Editor: Todd A. Cohen x
- Refine by Access: All Content x
Abstract
Objective—To compare effects of isoflurane and propofol on the cystometrogram and urethral pressure profile (UPP) in healthy female cats.
Animals—6 healthy female cats.
Procedures—Cats were anesthetized, and a consistent plane of anesthesia was maintained with low and high doses of isoflurane and propofol. A 6-F double-lumen urinary catheter was placed aseptically in the urethra for cystometrogram and UPP measurements. Threshold pressure and volume were recorded for cystometrograms. Maximum urethral pressure for smooth and skeletal muscle portions of the urethra, maximum urethral closure pressure, and functional profile length were measured during each UPP measurement. Heart rate and respiratory rate were recorded.
Results—Cats anesthetized with the low dose of propofol had consistent detrusor reflexes, compared with results for the other anesthetics. Mean ± SD threshold pressure, volume per unit of body weight, and compliance were 75.7 ± 16.3 cm H2O, 8.3 ± 3.2 mL/kg, and 0.5 ± 0.4 mL/cm H2O, respectively, for low-dose propofol. Anesthesia with either dose of propofol caused a significantly higher percentage change in heart rate during the cystometrogram, compared with results for anesthesia with isoflurane. Maximal urethral pressure in the area corresponding to skeletal muscle and the maximum urethral closure pressure were significantly higher for the low dose of propofol, compared with results for the high dose of propofol.
Conclusions and Clinical Relevance—The low-dose propofol regimen was the easiest to titrate and maintain and yielded diagnostic-quality detrusor reflexes in all 6 cats. Anesthetic depth should be titrated appropriately when performing urodynamic procedures.
Abstract
Objective—To evaluate accuracy of 6 portable blood glucose meters (PBGMs) by comparing results of these meters with results obtained with a reference chemistry analyzer.
Design—Evaluation study.
Animals—49 dogs (158 blood samples).
Procedures—Venous blood samples were tested with the 6 PBGMs, and results were compared with results of a commercially available analyzer that used a reference method based on the hexokinase reaction.
Results—Plasma glucose concentrations obtained with the reference analyzer ranged from 41 to 639 mg/dL. There were significant correlations between blood glucose concentrations obtained with the 6 PBGMs and plasma glucose concentrations obtained with the reference analyzer (r ≥ 0.96). However, for all 6 PBGMs, results differed from results for the reference analyzer, with the difference increasing as plasma glucose concentration increased. Significant differences in bias were found among meters. For 142 samples classified as hypoglycemic, euglycemic, or hyperglycemic on the basis of results of the reference analyzer, the percentage of samples that were misclassified on the basis of results of the PBGMs ranged from 2.1% to 38.7%.
Conclusions and Clinical Relevance—Results of the present study suggested that there were substantial differences in the accuracy of currently available PBGMs when used to determine blood glucose concentration in dogs.
Abstract
OBJECTIVE
To review ordering patterns, positivity rates, and outcome data for a subset of consecutive samples submitted for a commercially available, blood-based multicancer early-detection liquid biopsy test for dogs using next-generation sequencing at 1 laboratory.
SAMPLE
1,500 consecutively submitted blood samples from client-owned dogs with and without clinical suspicion and/or history of cancer for prospective liquid biopsy testing between December 28, 2021, and June 28, 2022.
PROCEDURES
We performed a retrospective observational study, reviewing data from 1,500 consecutive clinical samples submitted for liquid biopsy testing. Outcome data were obtained via medical record review, direct communication with the referring clinic, and/or a patient outcome survey through October 16, 2022.
RESULTS
Sixty-four percent (910/1,419) of reportable samples were submitted for cancer screening, 26% (366/1,419) for aid in diagnosis, and 10% (143/1,419) for other indications. The positivity rate was 25.4% (93/366) in aid-in-diagnosis patients and 4.5% (41/910) in screening patients. Outcome data were available for 33% (465/1,401) of patients, and outcomes were classifiable for 428 patients. The relative observed sensitivity was 61.5% (67/109) and specificity was 97.5% (311/319). The positive predictive value was 75.0% (21/28) for screening patients and 97.7% (43/44) for aid-in-diagnosis patients, and the time to diagnostic resolution following a positive result was < 2 weeks in most cases.
CLINICAL RELEVANCE
Liquid biopsy using next-generation sequencing represents a novel tool for noninvasive detection of cancer in dogs. Real-world clinical performance meets or exceeds expectations established in the test’s clinical validation study.