Abstract
OBJECTIVE
To evaluate cardiac output (CO) measurements using transpulmonary ultrasound (TPUD) technology and compare results with those of the gold standard, pulmonary arterial catheter thermodilution (PACTD), in 6 healthy anesthetized pigs during acute hemodynamic changes caused by manipulation of the blood volume.
ANIMALS
6 healthy male Landrace pigs.
PROCEDURES
Over a period of 1 week, pigs were anesthetized with isoflurane, mechanically ventilated, and underwent instrumentation in dorsal recumbency. They were subjected to sequential experimental states during which the blood volume was manipulated so that the animals transitioned from normovolemia to hypovolemia (20% and 40% of blood volume depletion), back to normovolemia (autologous blood transfusion), and then to hypervolemia (following colloid bolus). During each volume state, CO measurements were compared between TPUD and PACTD.
RESULTS
The mean ± SD relative bias between TPUD and PACTD was 7.71% ± 21.2% with limits of agreement –33.9% to 49.3%, indicating TPUD slightly underestimated CO values, compared with values obtained with PACTD. The mean ± SD of the bias between the 2 methods was 0.13 ± 0.5 L/min. Only 5 of 36 (13.9%) TPUD CO measurements had an absolute value of relative bias > 30%. The percentage error calculated for TPUD was 29.4%.
CLINICAL RELEVANCE
Results suggested that TPUD measurements have acceptable agreement with PACTD measurements. Moreover, TPUD exhibits promising potential in being used interchangeably with PACTD for future hemodynamic research involving swine as species of interest.
Abstract
OBJECTIVE
To investigate the relationship between invasively measured stroke volume (SV) and (1) esophageal Doppler-derived indices such as stroke distance (StrokeD), flow time corrected (FTc), stroke distance variation (SDV), and peak velocity variation (PVV); and (2) arterial load (AL) variables during evaluation of fluid responsiveness (FR) in anesthetized dogs undergoing sudden hemodynamic shifts in blood volume.
ANIMALS
6 healthy male dogs.
PROCEDURES
Dogs were anesthetized with isoflurane, ventilated mechanically, and instrumented to undergo sequential, nonrandomized experimental stages. The dogs transitioned from normovolemia (NORMO-BL) to hypovolemia (30% blood loss; HYPO-30), followed by autologous blood transfusion, and then to hypervolemia (colloid bolus). During each stage, SV was quantified using pulmonary artery thermodilution and its relationship with StrokeD, FTc, SDV, and PVV; and AL variables such as effective arterial elastance (Ea), dynamic arterial elastance (Eadyn), and total arterial compliance (Ca) were established.
RESULTS
As SV decreased significantly during HYPO-30 compared to NORMO-BL, there was a significant (P < .001) decrease in StrokeD, FTc, and Ca, with simultaneous increases in SDV, PVV, Ea, and Eadyn. Upon restoration of blood volume, these values stabilized closer to NORMO-BL. A significant (P < .001) correlation was observed between SV and StrokeD, FTc, Ea, Eadyn, and Ca.
CLINICAL RELEVANCE
Minimally invasive StrokeD, FTc, SDV, and PVV act as SV surrogates and help assess FR during different blood volume stages in healthy dogs. During hypovolemia-induced hypotension, Ea, Eadyn, and Ca may be able to guide therapeutic decisions favoring improvement in blood pressure and SV.
Abstract
OBJECTIVE
To compare cardiac output (CO) measurements by transesophageal echocardiography (TEECO) and esophageal Doppler monitor (EDMCO) with pulmonary artery thermodilution (PATDCO) in anesthetized dogs subjected to pharmacological interventions. The effect of treatments on EDM-derived indexes was also investigated.
ANIMALS
6 healthy male dogs (10.8 ± 0.7 kg).
METHODS
Dogs were anesthetized with propofol and isoflurane, mechanically ventilated, and monitored with invasive mean arterial pressure (MAP), end-tidal isoflurane concentration (ETISO), PATDCO, TEECO, EDMCO, and EDM-derived indexes. Four treatments were administered to all dogs by randomization. Baseline data were collected before each treatment: (1) dobutamine infusion; (2) esmolol infusion; (3) phenylephrine infusion; and (4) ETISO > 3%. Data were collected after 10-minute stabilization and after 30 minutes of washout between treatments. Statistical tests were pairwise t test, Bland-Altman analysis, Lin's concordance correlation (ρc), and polar plot analysis with P < .05 set as significance.
RESULTS
The mean ± SD relative bias (limits of agreement) for TEECO was 0.35 ± 25.2% (−49.1% to 49.8%) and for EDMCO was −27.2 ± 22.5% (−71.4% to 17%) versus PATDCO. The percent error for TEECO and EDMCO was 27.6% and 44.1%, respectively. The ρc value was 0.82 for TEECO and 0.66 for EDMCO. TEECO and EDMCO showed good trending ability. EDM-derived indexes displayed significant changes specific to the drug administered (P < .001).
CLINICAL RELEVANCE
For minimally invasive CO monitoring, TEE may provide more favorable performance than EDM in clinical settings; however, EDM-derived indexes yield valuable hemodynamic information that reliably follows trends in CO, thus supporting critical decision-making in canine patients.