Search Results
You are looking at 1 - 2 of 2 items for
- Author or Editor: Sarah M. Rosanowski x
- Refine by Access: All Content x
Abstract
OBJECTIVE
To evaluate and compare the prognosis for Thoroughbred racehorses to return to galloping and racing with injuries to the palmaroproximal metacarpus diagnosed with MRI.
ANIMALS
29 flat racing Thoroughbreds at the Hong Kong Jockey Club that underwent MRI between 2014 and 2022.
METHODS
Clinical, radiographic, ultrasonographic, and MRI reports were collected from veterinary clinical records, and these were combined with training and racing data. Horses were categorized on the basis of MRI diagnosis: (1) proximal suspensory ligament (PSL) involvement only, (2) PSL and concurrent proximal third metacarpal (MC3) bone involvement, and (3) proximal MC3 bone involvement only. The following were compared for prognosis for return to athletic function: return to galloping or racing, and reinjury.
RESULTS
Overall, the prognosis for return to athletic function was fair, with 92% (22/24; P = .53) and 67% (16/24; P = .73) of horses returning to galloping and racing, respectively. There was a relatively low reinjury rate, with 18% (4/22) of horses reinjuring. Horses with concurrent injury to both the PSL and proximal MC3 bone (Category 2) took longer to return to gallop (median, 116; IQR, 100.5 to 160), when compared with horses having only PSL injury (median, 69; IQR, 43 to 80; P = .04). Of the 4 horses that reinjured, 3 (75%) were horses in Category 2.
CLINICAL RELEVANCE
The findings from this study suggest that injuries involving both PSL and proximal MC3 bone concurrently require a longer rehabilitation period than those with PSL involvement alone.
Abstract
OBJECTIVE
To evaluate the effect of exposure to a balanced electrolyte solution (BES), or equine abdominal fat on the knot-holding capacity (KHC), relative knot security (RKS), weight, and volume of forwarder knots versus surgeon's knots.
SAMPLE
315 knots tied and tested in vitro.
PROCEDURES
United States Pharmacopeia size-3 polyglactin 910 suture exposed to air (dry [control]), equine abdominal fat (fat-exposed), or BES (BES-exposed) was used to tie forwarder knots with 2, 3, and 4 throws and surgeon's knots with 5, 6, 7, and 8 throws. A universal materials testing machine was used to test the tensile strength of suture and knots to failure, and the KHC, RKS, weight, and volume of knots were determined.
RESULTS
Forwarder knots had significantly higher KHC and RKS and lower volume, compared with surgeons’ knots. Forwarder knots tied with fat-exposed suture had greater weight, but not volume, than did forwarder knots tied with dry or BES-exposed suture with the same number of throws.
CONCLUSIONS AND CLINICAL RELEVANCE
Results indicated that forwarder knots were superior to surgeon's knots when configured as start knots intended for continuous lines of suture. Exposure to media did not negatively affect mechanical or physical properties of forwarder knots and may improve specific biomechanical functions, including KHC and RKS.