Abstract

OBJECTIVE To compare pursestring, Witzel (seromuscular inversion), and seromuscular incision jejunostomy tube placement techniques in vitro.

SAMPLE Jejunal specimens from 10 dogs.

PROCEDURES Jejunal segments (50 cm) were harvested immediately prior to euthanasia from 10 mixed-breed dogs Specimens were harvested with the orad and aborad ends clamped and stored in saline (0.9% NaCl) solution–soaked towels during instrumentation. Three jejunostomy tubes were placed via 3 techniques (pursestring, Witzel, and seromuscular incision), and 2 double lumen central venous catheters were placed at each intestinal end for luminal filling and leak testing. Intestinal luminal area was measured ultrasonographically with specimens suspended in a warm undyed saline solution bath with the intestinal lumen filled with dyed saline solution (intraluminal pressure, 6 mm Hg). Leak testing was performed by means of infusion of dyed saline solution (4 mL/min) until each jejunostomy site failed. Intestinal luminal area and leakage pressure were compared between the 3 tube placement techniques.

RESULTS The Witzel and seromuscular incision techniques decreased the intestinal luminal area measured at the tube insertion site, albeit nonsignificantly. For the seromuscular incision technique, a significant decrease in intestinal luminal area at the intraluminal site of measurement was found. For 2/30 specimens (1/10 pursestring and 1/10 seromuscular incision), failure occurred at pressures within the range of previously reported peak peristaltic pressure for dogs. Failure occurred at supraphysiologic peristaltic pressures for the remaining 28 specimens, including all 10 specimens for the Witzel technique.

CONCLUSIONS AND CLINICAL RELEVANCE In this in vitro study, all specimens for the Witzel technique withstood physiologic peristaltic pressures during leak testing. Both tunneling techniques (Witzel and seromuscular incision) created a decrease in intestinal luminal area. Further investigation, including in vivo testing, is indicated to evaluate the clinical relevance of these findings.

Full access
in American Journal of Veterinary Research

Abstract

OBJECTIVE To evaluate the closure rate and completeness of closure for a silicone–polyacrylic acid gradual venous occlusion device placed around an intra-abdominal vein to simulate gradual occlusion of an extrahepatic portosystemic shunt.

ANIMALS 3 purpose-bred cats and 2 purpose-bred dogs.

PROCEDURES The device was surgically placed around an external (cats) or internal (dogs) iliac vein. Computed tomographic angiography was performed at the time of surgery and 2, 4, and 6 weeks after surgery. Ultrasonographic examinations of blood flow through the vein within the device were performed at the time of surgery and at weekly intervals thereafter. Dogs were euthanized 6 weeks after surgery, and the external iliac veins were harvested for histologic examination.

RESULTS The prototype gradual venous occlusion device was successfully placed in all animals, and all animals recovered without complications following the placement procedure. The vessel was completely occluded in 2 cats by 6 weeks after surgery, as determined on the basis of results of CT and ultrasonography; there was incomplete occlusion with a luminal diameter of 1.5 mm in the other cat by 6 weeks after surgery. The vessel was completely occluded in both dogs by 6 weeks after surgery. Histologic examination of the external iliac veins obtained from the dogs revealed minimal inflammation of the vessel wall and no thrombus formation.

CONCLUSIONS AND CLINICAL RELEVANCE The prototype device induced gradual attenuation of an intra-abdominal vessel over a 6-week period. This device may provide another option for gradual occlusion of extrahepatic portosystemic shunts.

Full access
in American Journal of Veterinary Research