Search Results

You are looking at 1 - 2 of 2 items for

  • Author or Editor: Richard D. Sisson Jr x
  • Refine by Access: All Content x
Clear All Modify Search

SUMMARY

A 3.5-mm cortical orthopedic screw was compared with a 4.0-mm cancellous screw for maximal load to failure in the pelvis of immature dogs. The pelvis from young cadavers (7 to 13 months old) was divided into hemipelves and used for testing of the 2 screw types. Two sites in each hemipelvis were used, mid-shaft of the ilium and mid-sacrum, including the wing of the ilium. The screws were extracted, and maximal load to failure and mode of failure were recorded. Maximal load to failure per millimeter of engaged thread was calculated. In either pelvic site, the 4.0-mm cancellous screw required a significantly (P < 0.05) higher pullout force per millimeter of engaged screw threads than did the 3.5-mm cortical bone screw.

Free access
in American Journal of Veterinary Research