OBJECTIVE
To compare the torsional mechanical properties of 2 external skeletal fixators (ESFs) placed with 2 intramedullary pin (IP) and transfixation pin (TP) size combinations in a model of raptor tibiotarsal bone fracture.
SAMPLE
24 ESF-synthetic tibiotarsal bone model (polyoxymethylene) constructs.
PROCEDURES
Synthetic bone models were fabricated with an 8-mm (simulated fracture) gap. Four types of ESF-synthetic bone model constructs (6/group) were tested: a FESSA with a 1.6-mm IP and 1.6-mm TPs, a FESSA with a 2.0-mm IP and 1.1-mm TPs, an acrylic connecting bar with a 1.6-mm IP and 1.6-mm TPs, and an acrylic connecting bar with a 2.0-mm IP and 1.1-mm TPs. Models were rotated in torsion (5°/s) to failure or the machine angle limit (80°). Mechanical variables at yield and at failure were determined from load deformation curves. Effects of overall construct type, connecting bar type, and IP and TP size combination on mechanical properties were assessed with mixed-model ANOVAs.
RESULTS
Both FESSA constructs had significantly greater median stiffness and median torque at yield than both acrylic bar constructs; FESSA constructs with a 1.6-mm IP and 1.6-mm TPs had greatest stiffness of all tested constructs and lowest gap strain at yield. No FESSA constructs failed during testing; 7 of 12 acrylic bar constructs failed by fracture of the connecting bar at the interface with a TP.
CONCLUSIONS AND CLINICAL RELEVANCE
Although acrylic bar ESFs have been successfully used in avian patients, the FESSA constructs in this study were mechanically superior to acrylic bar constructs, with greatest benefit resulting from use with the larger TP configuration.
Abstract
OBJECTIVE
To evaluate radiation exposure of dogs and cats undergoing procedures requiring intraoperative fluoroscopy and for operators performing those procedures.
SAMPLE
360 fluoroscopic procedures performed at 2 academic institutions between 2012 and 2015.
PROCEDURES
Fluoroscopic procedures were classified as vascular, urinary, respiratory, cardiac, gastrointestinal, and orthopedic. Fluoroscopy operators were classified as interventional radiology-trained clinicians, orthopedic surgeons, soft tissue surgeons, internists, and cardiologists. Total radiation exposure in milligrays and total fluoroscopy time in minutes were obtained from dose reports for 4 C-arm units. Kruskal-Wallis equality of populations rank tests and Dunn pairwise comparisons were used to compare differences in time and exposure among procedures and operators.
RESULTS
Fluoroscopy time (median, 35.80 minutes; range, 0.60 to 84.70 minutes) was significantly greater and radiation exposure (median, 137.00 mGy; range, 3.00 to 617.51 mGy) was significantly higher for vascular procedures than for other procedures. Median total radiation exposure was significantly higher for procedures performed by interventional radiology-trained clinicians (16.10 mGy; range, 0.44 to 617.50 mGy), cardiologists (25.82 mGy; range, 0.33 to 287.45 mGy), and internists (25.24 mGy; range, 3.58 to 185.79 mGy).
CONCLUSIONS AND CLINICAL RELEVANCE
Vascular fluoroscopic procedures were associated with significantly longer fluoroscopy time and higher radiation exposure than were other evaluated fluoroscopic procedures. Future studies should focus on quantitative radiation monitoring for patients and operators, importance of operator training, intraoperative safety measures, and protocols for postoperative monitoring of patients.