Search Results

You are looking at 1 - 2 of 2 items for

  • Author or Editor: Krista L. Jones x
  • Refine by Access: All Content x
Clear All Modify Search

Abstract

OBJECTIVE To use CT-derived measurements to create a ferret-specific formula for body surface area (BSA) to improve chemotherapeutic dosing.

ANIMALS 25 adult ferrets (19 live and 6 cadavers).

PROCEDURES Live subjects were weighed, and body measurements were obtained by each of 3 observers while ferrets were awake and anesthetized. Computed tomography was performed, and a 3-D surface model was constructed with open-source imaging software, from which BSA was estimated. The CT-derived values were compared with BSA calculated on the basis of the traditional tape method for 6 cadavers. To further validate CT analysis software, 11 geometric shapes were scanned and their CT-derived values compared with those calculated directly via geometric formulas. Agreement between methods of surface area estimation was assessed with linear regression. Ferret-specific formulas for BSA were determined with nonlinear regression models.

RESULTS Repeatability among the 3 observers was good for all measurements, but some measurements differed significantly between awake and anesthetized ferrets. Excellent agreement was found between measured versus CT-derived surface area of shapes, traditional tape– versus CT-derived BSA of ferret cadavers, and CT-derived BSA of cadavers with and without monitoring equipment. All surface area formulas performed relatively similarly.

CONCLUSIONS AND CLINICAL RELEVANCE CT-derived BSA measurements of ferrets obtained via open-source imaging software were reliable. On the basis of study results, the recommended formula for BSA in ferrets would be 9.94 × (body weight)2/3; however, this represented a relatively minor difference from the feline-derived formula currently used by most practitioners and would result in little practical change in drug doses.

Full access
in American Journal of Veterinary Research

Abstract

OBJECTIVE

To establish a reference interval for glomerular filtration rate (GFR) determined by measuring serum clearance of a single IV dose of inulin in clinically normal cheetahs (Acinonyx jubatus) and compare serum symmetric dimethylarginine (SDMA) concentration in cheetahs with GFR.

ANIMALS

33 cheetahs housed at 3 institutions.

PROCEDURES

A single bolus of inulin (3,000 mg/m2) was administered IV, and 5 serial blood samples were collected and analyzed for serum inulin concentration with the anthrone technique. The GFR was estimated with a modified slope-intercept method for the slow component of the serum concentration-versus-time curve. Blood urea nitrogen and serum creatinine concentrations were measured in samples obtained immediately prior to inulin administration, and serum SDMA concentration was measured in stored samples.

RESULTS

Mean ± SD measured GFR was 1.58 ± 0.39 mL/min/kg, and the calculated reference interval was 0.84 to 2.37 mL/min/kg. There were significant negative correlations between GFR and serum creatinine concentration (r = −0.499), BUN concentration (r = −0.592), and age (r = −0.463). Serum SDMA concentration was not significantly correlated with GFR (r = 0.385), BUN concentration (r = −0.281), or serum creatinine concentration (r = 0.165).

CONCLUSIONS AND CLINICAL RELEVANCE

A reference interval for GFR in clinically normal cheetahs was obtained. Further evaluation of animals with renal disease is needed to determine whether measuring serum clearance of a single IV dose of inulin is a reliable diagnostic test for early detection of renal disease in cheetahs.

Full access
in American Journal of Veterinary Research