Search Results
You are looking at 1 - 2 of 2 items for
- Author or Editor: Jennifer Kinns x
- Refine by Access: All Content x
Abstract
Case Description—A dog was examined because of a 6-month history of upper airway stridor that began after postoperative regurgitation of gastric contents.
Clinical Findings—Constant stridor was evident during inspiration and expiration, although it was worse during inspiration. The stridor was no longer evident when the dog's mouth was manually held open. Computed tomography, rhinoscopy, and fluoroscopy were used to confirm a diagnosis of nasopharyngeal stenosis.
Treatment and Outcome—The dog was anesthetized, and balloon dilatation of the stenosis was performed. Prednisone was prescribed for 4 weeks after the procedure to decrease fibrous tissue formation. Although the dog was initially improved, signs recurred 3.5 weeks later, and balloon dilatation was repeated. This time, however, triamcinolone was injected into the area of stenosis at the end of the dilatation procedure. Two months later, although the dog did not have clinical signs of stridor, a third dilatation procedure was performed because mild stenosis was seen on follow-up computed tomographic images; again, triamcinolone was injected into the area of stenosis at the end of the dilatation procedure. Three and 6 months after the third dilatation procedure, the dog reportedly was clinically normal.
Clinical Relevance—Findings suggest that balloon dilatation may be an effective treatment for nasopharyngeal stenosis in dogs.
Abstract
Objective—To compare accuracy of estimates of cystolith size obtained by means of plain radiography, double-contrast cystography, ultrasonography, and computed tomography.
Sample Population—30 canine cystoliths ranging from 1 to 11 mm in diameter with various mineral compositions.
Procedures—A bladder phantom model was created by filling a rubber balloon with saline (1% NaCl) solution and positioning it on top of a 2% gelatin cushion at the bottom of a water-filled 4-quart container. Cystoliths were individually placed in the bladder phantom and imaged by each of the 4 techniques. For each image, cystolith size was measured by 2 radiologists with computerized calipers, and size estimates were compared with actual cystolith size.
Results—Mean cystolith size estimates obtained by means of radiography, cystography, and computed tomography did not differ significantly from each other. However, for ultrasonographic images, mean ± SD difference between actual and estimated cystolith size (2.95 ± 0.73 mm) was significantly higher than mean difference for radiographic, cystographic, and computed tomographic images. For ultrasonography, mean ± SD percentage overestimation in cystolith size was 68.4 ± 51.5%.
Conclusions and Clinical Relevance—Results indicated that measurements of cystolith size obtained by means of ultrasonography may overestimate the true size. This suggests that cystolith size estimates obtained by means of ultrasonography should be interpreted with caution whenever cystolith size may influence patient management.