Abstract

OBJECTIVE To compare blood pressure measured noninvasively with an oscillometric device that involved use of a novel conical cuff and a traditional cylindrical blood pressure cuff.

ANIMALS 17 adult hound-type dogs.

PROCEDURES Dogs were anesthetized, and a 20-gauge, 1.5-inch catheter was inserted in the median sacral artery. The catheter was attached to a pressure transducer via fluid-filled noncompliant tubing, and direct blood pressure was recorded with a multifunction monitor. A specially fabricated conical cuff was placed on the antebrachium. Four sets of direct and indirect blood pressure measurements were simultaneously collected every 2 minutes. Four sets of measurements were then obtained by use of a cylindrical cuff.

RESULTS The cylindrical cuff met American College of Veterinary Internal Medicine consensus guidelines for validation of indirect blood pressure measurements for mean arterial blood pressure (MAP), systolic arterial blood pressure (SAP), and diastolic arterial blood pressure (DAP). The conical cuff met the consensus guidelines for difference of paired measurements, SD, and percentages of measurements within 10 and 20 mm Hg of the value for the reference method, but it failed a correlation analysis. In addition, although bias for the conical cuff was less than that for the cylindrical cuff for SAP, MAP, and DAP measurements, the limits of agreement for the conical cuff were wider than those for the cylindrical cuff for SAP and MAP measurements.

CONCLUSIONS AND CLINICAL RELEVANCE On the basis of results of this study, use of a conical cuff for oscillometric blood pressure measurement cannot be recommended.

Full access
in American Journal of Veterinary Research

Abstract

OBJECTIVE To determine whether directly measured arterial blood pressure differs among anatomic locations and whether arterial blood pressure is influenced by body position.

ANIMALS 33 client-owned dogs undergoing anesthesia.

PROCEDURES Dogs undergoing anesthetic procedures had 20-gauge catheters placed in both the superficial palmar arch and the contralateral dorsal pedal artery (group 1 [n = 20]) or the superficial palmar arch and median sacral artery (group 2 [13]). Dogs were positioned in dorsal recumbency, and mean arterial blood pressure (MAP), systolic arterial blood pressure (SAP), and diastolic arterial blood pressure (DAP) were recorded for both arteries 4 times (2-minute interval between successive measurements). Dogs were positioned in right lateral recumbency, and blood pressure measurements were repeated.

RESULTS Differences were detected between pressures measured at the 2 arterial sites in both groups. This was especially true for SAP measurements in group 1, in which hind limb measurements were a mean of 16.12 mm Hg higher than carpus measurements when dogs were in dorsal recumbency and 14.70 mm Hg higher than carpus measurements when dogs were in lateral recumbency. Also, there was significant dispersion about the mean for all SAP, DAP, and MAP measurements.

CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that arterial blood pressures may be dependent on anatomic location and body position. Because this may affect outcomes of studies conducted to validate indirect blood pressure measurement systems, care must be used when developing future studies or interpreting previous results.