Search Results
You are looking at 1 - 2 of 2 items for
- Author or Editor: Donghyun Oh x
- Refine by Access: All Content x
Abstract
OBJECTIVE
To evaluate a contrast medium that could be used for radiographic and ultrasonographic assessment of the small intestine in dogs.
ANIMALS
8 healthy adult Beagles.
PROCEDURES
Carboxymethylcellulose (CMC; 0.5% solution) was combined with iohexol (300 mg of iodine/mL) to yield modified contrast medium (MCM). Dogs were orally administered the first of 3 MCMs (10 mL/kg [9.5 mL of CMC/kg plus 0.5 mL of iohexol/kg]). Radiographic and ultrasonographic assessment of the small intestine followed 10 minutes after administration and every 10 minutes thereafter, until MCM was seen within the ascending colon. Minimally, 1 week elapsed between dosing of subsequent MCMs (10 mL/kg [9 mL of CMC/kg plus 1 mL of iohexol/kg and 8.5 mL of CMC/kg plus 1.5 mL of iohexol/kg]) and repeated radiography and ultrasonography.
RESULTS
Radiographic contrast enhancement of the small intestine was best with MCM that combined 8.5 mL of CMC/kg and 1.5 mL of iohexol/kg. Mean small intestinal transit time for all MCMs was 86 minutes. All MCMs did not interfere with ultrasonographic assessment of the small intestine and may have improved visualization of the far-field small intestinal walls.
CONCLUSIONS AND CLINICAL RELEVANCE
An MCM that combined 8.5 mL of 0.5% CMC/kg and 1.5 mL of iohexol/kg could be an alternative to barium or iohexol alone for contrast small intestinal radiography in dogs, especially when abdominal ultrasonography is to follow contrast radiography.
Abstract
OBJECTIVE
To evaluate stiffness of the liver parenchyma in healthy adult cats by means of point shear wave elastography (PSWE).
ANIMALS
18 client-owned adult (1- to 6-year-old) healthy cats.
PROCEDURES
Echogenicity and echotexture of the liver parenchyma were assessed by means of conventional B-mode ultrasonography. The shear wave velocity (Vs) of the right and left portions of the liver were measured by means of PSWE.
RESULTS
B-mode ultrasonography revealed no abnormalities in echotexture or echogenicity of the liver parenchyma in any cat. Mean (95% CI) Vs in the liver parenchyma was 1.46 m/s (1.36 to 1.55 m/s) for the right portion, 1.36 m/s (1.26 to 1.47 m/s) for the left portion, and 1.43 m/s (1.35 to 1.51 m/s) overall. The difference in mean Vs between the 2 portions of the liver was significant. No significant correlation was found between Vs and body weight or between Vs and the depth at which this variable was measured.
CONCLUSIONS AND CLINICAL RELEVANCE
Quantitative PSWE of the liver was feasible in healthy adult cats. The obtained values for Vs may be useful for interpretation of and comparison with values measured in cats with liver disease. Additional research is needed to explore the potential usefulness of PSWE for diagnostic purposes.