Search Results

You are looking at 1 - 5 of 5 items for

  • Author or Editor: Thomas N. Tully Jr x
  • Refine by Access: Content accessible to me x
Clear All Modify Search

Abstract

Objective—To determine the pharmacokinetics and safety of voriconazole administered orally in single and multiple doses in Hispaniolan Amazon parrots (Amazona ventralis).

Animals—15 clinically normal adult Hispaniolan Amazon parrots.

Procedures—Single doses of voriconazole (12 or 24 mg/kg) were administered orally to 15 and 12 birds, respectively; plasma voriconazole concentrations were determined at intervals via high-pressure liquid chromatography. In a multiple-dose trial, voriconazole (18 mg/kg) or water was administered orally to 6 and 4 birds, respectively, every 8 hours for 11 days (beginning day 0); trough plasma voriconazole concentrations were evaluated on 3 days. Birds were monitored daily, and clinicopathologic variables were evaluated before and after the trial.

Results—Voriconazole elimination half-life was short (0.70 to 1.25 hours). In the single-dose experiments, higher drug doses yielded proportional increases in the maximum plasma voriconazole concentration (Cmax) and area under the curve (AUC). In the multiple-dose trial, Cmax, AUC, and plasma concentrations at 2 and 4 hours were decreased on day 10, compared with day 0 values; however, there was relatively little change in terminal half-life. With the exception of 1 voriconazole-treated parrot that developed polyuria, adverse effects were not evident.

Conclusions and Clinical Relevance—In Hispaniolan Amazon parrots, oral administration of voriconazole was associated with proportional kinetics following administration of single doses and a decrease in plasma concentration following administration of multiple doses. Oral administration of 18 mg of voriconazole/kg every 8 hours would require adjustment to maintain therapeutic concentrations during long-term treatment. Safety and efficacy of voriconazole treatment in this species require further investigation.

Full access
in American Journal of Veterinary Research

Abstract

Objective—To establish a computed tomography (CT)-angiography protocol and measure the diameters of major arteries in parrots.

Animals—13 Hispaniolan Amazon parrots (Amazona ventralis).

Procedures—16-slice CT scanning was used to measure the apparent diameter of the ascending aorta, abdominal aorta, pulmonary arteries, and brachiocephalic trunk. Before scanning, all birds underwent ECG and echocardiographic assessment and were considered free of detectable cardiovascular diseases. Each bird was anesthetized, and a precontrast helical CT scan was performed. Peak aortic enhancement was established with a test bolus technique via dynamic axial CT scan over a predetermined single slice. An additional bolus of contrast medium was then injected, and a helical CT-angiography scan was performed immediately afterward. Arterial diameter measurements were obtained by 2 observers via various windows before and after injection, and intra- and interobserver agreement was assessed.

Results—Reference limits were determined for arterial diameter measurements before and after contrast medium administration in pulmonary, mediastinal, and manual angiography windows. Ratios of vertebral body diameter to keel length were also calculated. Intraobserver agreement was high (concordance correlation coefficients ≥ 0.95); interobserver agreement was medium to high (intraclass correlation coefficients ≥ 0.65).

Conclusions and Clinical Relevance—CT-angiography was safe and is of potential diagnostic value in parrots. We recommend performing the angiography immediately after IV injection of 3 mL of iohexol/kg. Arterial diameter measurements at the described locations were reliable.

Full access
in American Journal of Veterinary Research

Abstract

Objective—To determine plasma osmolality in healthy adult Hispaniolan Amazon parrots (Amazona ventralis) and validate osmolality equations in these parrots.

Animals—20 healthy adult Hispaniolan Amazon parrots.

Procedures—A blood sample (0.5 mL) was collected from the right jugular vein of each parrot and placed into a lithium heparin microtainer tube. Samples were centrifuged, and plasma was harvested and frozen at −30°C. Samples were thawed, and plasma osmolality was measured in duplicate with a freezing-point depression osmometer. The mean value was calculated for the 2 osmolality measurements.

Results—Plasma osmolality values were normally distributed, with a mean ± SD of 326.0 ± 6.878 mOsm/kg. The equations (2 × [Na+ + K+]) + (glucose/18), which resulted in bias of 2.3333 mOsm/kg and limits of agreement of −7.0940 to 11.7606 mOsm/kg, and (2 × [Na+ + K+]) + (uric acid concentration/16.8) + (glucose concentration/18), which resulted in bias of 5.8117 mOsm/kg and limits of agreement of −14.6640 to 3.0406 mOsm/kg, yielded calculated values that were in good agreement with the measured osmolality.

Conclusions and Clinical Relevance—IV administration of large amounts of hypotonic fluids can have catastrophic consequences. Osmolality of the plasma from parrots in this study was significantly higher than that of commercially available prepackaged fluids. Therefore, such fluids should be used with caution in Hispaniolan Amazon parrots as well as other psittacines. Additional studies are needed to determine whether the estimation of osmolality has the same clinical value in psittacines as it does in other animals.

Full access
in American Journal of Veterinary Research

Abstract

Objective—To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis).

Animals—20 healthy adult Hispaniolan Amazon parrots.

Procedures—A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) from a jugular vein of each parrot. Small volumes of blood (0.6 to 1.5 μL) were used to operate each of the blood glucose meters, and the remainder was placed into lithium heparin microtubes and centrifuged. Plasma was harvested and frozen at −30°C. Within 5 days after collection, plasma samples were thawed and plasma glucose concen-trations were measured by means of the laboratory analyzer. Agreement between pairs of blood glucose meters and between each blood glucose meter and the laboratory analyzer was evaluated by means of the Bland-Altman method, and limits of agreement (LOA) were calculated.

Results—None of the results of the 3 blood glucose meters agreed with results of the laboratory analyzer. Each point-of-care blood glucose meter underestimated the blood glucose concentration, and the degree of negative bias was not consistent (meter A bias, −94.9 mg/dL [LOA, −148.0 to −41.7 mg/dL]; meter B bias, −52 mg/dL [LOA, −107.5 to 3.5 mg/dL]; and meter C bias, −78.9 mg/dL [LOA, −137.2 to −20.6 mg/dL]).

Conclusions and Clinical Relevance—On the basis of these results, use of handheld blood glucose meters in the diagnosis or treatment of Hispaniolan Amazon parrots and other psittacines cannot be recommended.

Full access
in American Journal of Veterinary Research

Abstract

Objective—To assess the effects of dopamine and dobutamine on the blood pressure of isoflurane-anesthetized Hispaniolan Amazon parrots (Amazona ventralis).

Animals—8 Hispaniolan Amazon parrots.

Procedures—A randomized crossover study was conducted. Each bird was anesthetized (anesthesia maintained by administration of 2.5% isoflurane in oxygen) and received 3 doses of each drug during a treatment period of 20 min/dose. Treatments were constant rate infusions (CRIs) of dobutamine (5, 10, and 15 μg/kg/min) and dopamine (5, 7, and 10 μg/kg/min). Direct systolic, diastolic, and mean arterial pressure measurements, heart rate, esophageal temperature, and end-tidal partial pressure of CO2 were recorded throughout the treatment periods.

Results—Mean ± SD of the systolic, mean, and diastolic arterial blood pressures at time 0 (initiation of a CRI) were 132.9 ± 22.1 mm Hg, 116.9 ± 20.5 mm Hg, and 101.9 ± 22.0 mm Hg, respectively. Dopamine resulted in significantly higher values than did dobutamine for the measured variables, except for end-tidal partial pressure of CO2. Post hoc multiple comparisons revealed that the changes in arterial blood pressure were significantly different 4 to 7 minutes after initiation of a CRI. Overall, dopamine at rates of 7 and 10 μg/kg/min and dobutamine at a rate of 15 μg/kg/min caused the greatest increases in arterial blood pressure.

Conclusions and Clinical Relevance—Dobutamine CRI at 5, 10, and 15 μg/kg/min and dopamine CRI at 5, 7, and 10 μg/kg/min may be useful in correcting severe hypotension in Hispaniolan Amazon parrots caused by anesthesia maintained with 2.5% isoflurane.

Full access
in American Journal of Veterinary Research