Search Results

You are looking at 1 - 2 of 2 items for :

  • Author or Editor: Penny J. Regier x
  • Refine by Access: Content accessible to me x
Clear All Modify Search

Abstract

OBJECTIVE To compare security of continuous intradermal suture lines closed by use of barbed suture with 3 end-pass configurations or without an end-pass configuration.

SAMPLE 40 full-thickness, 4-cm-long, parasagittal wounds in canine cadavers.

PROCEDURES Each continuous intradermal closure was terminated with 1 of 3 end-pass techniques or without an end-pass configuration (control group). A servohydraulic machine applied tensile load perpendicular to the long axis of the suture line. A load-displacement curve was generated for each sample; maximum load, displacement, stiffness, mode of construct failure, and load at first suture slippage at termination (ie, terminal end of the suture line) were recorded.

RESULTS Values for maximum load, displacement, and stiffness did not differ significantly among the 3 end-pass techniques, and load at first suture slippage at termination was not significantly different among the 4 groups. A 1-pass technique slipped in 5 of 9 samples; 3 of these 5 slips caused failure of wound closure. A 2-pass technique slipped in 3 of 9 samples, none of which caused failure of wound closure. Another 2-pass technique slipped in 4 of 10 samples; 2 of these 4 slips caused failure of wound closure. The control group had slippage in 10 of 10 samples; 9 of 10 slips caused failure of wound closure

CONCLUSIONS AND CLINICAL RELEVANCE An end-pass anchor was necessary to terminate a continuous intradermal suture line, and all 3 end-pass anchor techniques were suitable to prevent wound disruption. The 2-pass technique for which none of the suture slippages caused wound closure failure provided the most reliable configuration.

Full access
in American Journal of Veterinary Research

Abstract

OBJECTIVE

To compare initial leak pressure (ILP) between cadaveric canine and synthetic small intestinal segments that did and did not undergo enterotomy.

SAMPLE

Eight 8-cm grossly normal jejunal segments from 1 canine cadaver and eight 8-cm synthetic small intestinal segments.

PROCEDURES

Intestinal segments were randomly assigned to undergo enterotomy (6 cadaveric and 6 synthetic segments) or serve as untreated controls (2 cadaveric and 2 synthetic segments). For segments designated for enterotomy, a 2-cm full-thickness incision was created along the antimesenteric border. The incision was closed in a single layer with 4-0 suture in a simple continuous pattern. Leak testing was performed with intestinal segments occluded at both ends and infused with dilute dye solution (999 mL/h) until the solution was observed leaking from the suture line or serosal tearing occurred. Intraluminal pressure was continuously monitored. The ILP at construct failure was compared between cadaveric and synthetic control segments and between cadaveric and synthetic enterotomy segments.

RESULTS

Mean ± SD ILP did not differ significantly between cadaveric (345.11 ± 2.15 mm Hg) and synthetic (329.04 ± 24.69 mm Hg) control segments but was significantly greater for cadaveric enterotomy segments (60.77 ± 15.81 mm Hg), compared with synthetic enterotomy segments (15.03 ± 6.41 mm Hg).

CONCLUSIONS AND CLINICAL RELEVANCE

Leak testing should not be used to assess the accuracy or security of enterotomy suture lines in synthetic intestinal tissue. Synthetic intestinal tissue is best used for students to gain confidence and proficiency in performing enterotomies before performing the procedure on live animals.

Full access
in American Journal of Veterinary Research