Abstract

Objective—To compare the mechanical properties of laryngeal tie-forward (LTF) surrogate constructs prepared with steel fixtures and No. 5 braided polyester or braided polyethylene by use of a standard or a modified suture placement technique.

Sample—32 LTF surrogate constructs.

Procedures—Surrogate constructs were prepared with steel fixtures and sutures (polyester or polyethylene) by use of a standard or modified suture placement technique. Constructs underwent single-load-to-failure testing. Maximal load at failure, elongation at failure, stiffness, and suture breakage sites were compared among constructs prepared with polyester sutures by means of the standard (n = 10) or modified (10) technique and those prepared with polyethylene sutures with the standard (6) or modified (6) technique.

Results—Polyethylene suture constructs had higher stiffness, higher load at failure, and lower elongation at failure than did polyester suture constructs. Constructs prepared with the modified technique had higher load at failure than did those prepared with the standard technique for both suture materials. All sutures broke at the knot in constructs prepared with the standard technique. Sutures broke at a location away from the knot in 13 of 16 constructs prepared with the modified technique (3 such constructs with polyethylene sutures broke at the knot).

Conclusions and Clinical Relevance—Results suggested LTF surrogate constructs prepared with polyethylene sutures or the modified technique were stronger than those prepared with polyester sutures or the standard technique.

Full access
in American Journal of Veterinary Research

Abstract

OBJECTIVE To compare the mechanical properties of laryngeal tie-forward (LTF) constructs prepared with different suture materials and suture placement patterns during single load to failure testing.

SAMPLE Larynges harvested from 50 horse cadavers and 5 intact horse cadavers.

PROCEDURES In vitro LTF constructs were created by a standard technique with polyester sutures, a standard technique with polyethylene sutures, a modified technique with metallic implants and polyester sutures, a modified technique with metallic implants and polyethylene sutures, or a modified tie-off technique with polyester sutures (10 of each type of construct). Mechanical properties including maximal load (N) at failure and failure mode were compared among constructs. Also, maximal loads at failure of the in vitro LTF constructs were compared with the loads exerted on the sutures tightened to achieve rostral laryngeal advancement in intact cadavers.

RESULTS Constructs prepared by a standard technique with polyethylene sutures had a significantly higher pull out strength than those prepared by a modified technique with metallic implants and either polyester or polyethylene sutures. For constructs prepared by a standard technique with polyethylene sutures or similarly placed polyester sutures, maximal load at failure did not differ but the failure mode did differ significantly. The load to failure for all in vitro constructs was higher than the maximal load measured during a range of motion test in intact horse cadavers.

CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that LTF procedures can be performed in live horses with any of the suture materials and techniques tested.