Search Results

You are looking at 1 - 6 of 6 items for

  • Author or Editor: Hock Gan Heng x
  • Refine by Access: Content accessible to me x
Clear All Modify Search

Abstract

OBJECTIVE To compare ultrasound biomicroscopy (UBM) with standard ocular ultrasonography for detection of canine uveal cysts and to determine the sensitivity, specificity, and interobserver agreement for detection of uveal cysts with UBM.

SAMPLE 202 enucleated eyes from 101 dogs.

PROCEDURES 2 examiners examined 202 eyes by means of UBM (50 MHz) to identify uveal cysts. A board-certified radiologist then examined 98 of the 202 eyes by means of standard ocular ultrasonography (7- to 12-MHz linear transducer). Subsequently, 1 examiner dissected all 202 eyes under magnification from an operating microscope to definitively identify uveal cysts. Each examiner was masked to other examiners’ findings. Sensitivity, specificity, and interobserver agreement were calculated for detection of cysts by UBM.

RESULTS Cysts were detected by use of UBM in 55 of 202 (27%) eyes by one examiner and 29 of 202 (14%) eyes by the other. No cysts were detected in the 98 eyes examined with standard ocular ultrasonography. Dissection results revealed that cysts were present in 64 of 202 (32%) eyes, including 29 of 98 (30%) eyes examined by standard ocular ultrasonography. Mean sensitivity of UBM for cyst detection was 47%; mean specificity was 92%. Uveal cysts not identified with UBM were often small (mean diameter, 490 üm). Interobserver agreement was high (κP = 0.81).

CONCLUSIONS AND CLINICAL RELEVANCE UBM was more effective than standard ocular ultrasonography for detection of uveal cysts in enucleated eyes. Small-diameter cysts were difficult to visualize even with UBM.

Full access
in American Journal of Veterinary Research

Abstract

In collaboration with the American College of Veterinary Radiology

Open access
in Journal of the American Veterinary Medical Association

Abstract

OBJECTIVE To develop a model of hip joint synovitis on the basis of intra-articular injection of a sodium urate suspension in dogs and to characterize associated gait changes.

ANIMALS 6 healthy adult dogs.

PROCEDURES Each dog was sedated, and synovitis was induced by injection of 1 mL of a sodium urate suspension (20 mg/mL) into the right hip joint under ultrasonographic guidance. Observational and instrumented gait analyses to determine temporospatial, kinetic, and kinematic variables were performed prior to and 4, 8, and 24 hours after sedation and synovitis induction.

RESULTS Injection of a sodium urate suspension into the hip joint of healthy dogs resulted in lameness of the ipsilateral pelvic limb as determined by observational and instrumented gait analyses. For all dogs, lameness was clinically detectable within 1.5 to 2 hours after injection, reached its maximum intensity at 4 hours after injection, and had subsided by 24 hours after injection.

CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that injection of a sodium urate suspension into the hip joint of healthy dogs reliably induced synovitis and signs of pain and lameness in the ipsilateral pelvic limb that lasted 24 hours. This model can be used in conjunction with instrumented gait analysis to provide information on gait changes associated with hip joint disease and might be useful for evaluating the efficacy of analgesics or other interventions for the treatment of hip joint disease in dogs.

Full access
in American Journal of Veterinary Research

Abstract

OBJECTIVE To evaluate the association between ultrasonographically measured optic nerve sheath diameter (ONSD) and acute increases in intracranial pressure (ICP) as measured by an epidural intracranial pressure monitoring system (EICPMS) in healthy dogs.

ANIMALS 6 young healthy dogs.

PROCEDURES An EICPMS connected to a pressure monitor was used to generate a continuous pressure waveform in each anesthetized dog. A 22-gauge IV catheter was inserted into the brain parenchyma through the contralateral parietal bone, and 0.5 to 2.0 mL of anticoagulated autologous blood was injected at predetermined intervals. At baseline (immediately after EICPMS placement) and following each injection, the ICP as indicated by EICPMS was recorded, and 3 ultrasonographic images of the optic nerve sheath of each eye were obtained. The ONSD was measured at maximum diameter and at 5 mm caudal to the optic disk.

RESULTS In linear models, the maximum ONSD was positively associated with increasing ICP. Specifically, the rate of maximum ONSD increase was greater for pressures ≤ 20 mm Hg above baseline (0.0534 mm/1 mm Hg ICP increase) than for pressures > 40 mm Hg above baseline (0.0087 mm/1 mm Hg ICP increase). The relationship of ICP to maximum ONSD was slightly nonlinear and best explained by comparison of fractional polynomial regression models.

CONCLUSIONS AND CLINICAL RELEVANCE ICP was positively and nonlinearly associated with increasing maximum ONSD, especially when ICP was ≤ 20 mm Hg above baseline, supporting the conclusion that ultrasonographic measurement of maximum ONSD may provide a noninvasive monitoring tool for evaluation of ICP in dogs. Further research is needed to assess the utility of these measurements in clinical patients.

Full access
in American Journal of Veterinary Research

Abstract

OBJECTIVE To determine the optimal protocol for acquisition of CT images of the dentition in alpacas.

ANIMALS 3 healthy adult male alpacas.

PROCEDURES Each alpaca was anesthetized with an IM injection of a combination of ketamine, xylazine, and butorphanol and positioned in sternal recumbency on the CT couch with its legs folded in a natural cush position and its head positioned within the isocenter of the gantry of a 64-slice CT scanner. Images were acquired by means of 6 protocols (sequential and helical modes at slice thicknesses of 1.25, 2.5, and 5 mm). Five images (2 molar, 2 premolar, and mandibular incisor teeth) were selected from each protocol for evaluation by 3 veterinary radiologists. For each image, tooth root visibility and sharpness and image noise artifact were subjectively evaluated on a 3-point scoring system.

RESULTS Slice thickness significantly affected tooth root visibility and tooth root sharpness but did not affect image noise artifact. Acquisition mode significantly affected tooth root visibility and tooth root sharpness as well as image noise artifact. Tooth root visibility and sharpness did not differ significantly between the helical and sequential images when the slice thickness was 1.25 mm. Image noise artifact was greater for helical images than sequential images but did not differ by slice thickness within either acquisition mode.

CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that for a 64-slice CT scanner, the optimal protocol for the acquisition of CT images of the dentition in alpacas was a sequential scan with a slice thickness of 1.25 mm.

Full access
in American Journal of Veterinary Research

Abstract

OBJECTIVE To compare time to achieve vascular access (TTVA) between an ultrasound-guided technique (UST) and landmark-based technique (LMT) for central venous catheter (CVC) placement in healthy anesthetized dogs.

ANIMALS 39 purpose-bred hounds.

PROCEDURES Anesthetized dogs that were hemodynamically stable following completion of a terminal surgical exercise were enrolled in the study during 2 phases, with a 45-day intermission between phases. For each dog, a UST and LMT were used for CVC placement via each external jugular vein by 2 operators (criticalist and resident). The TTVA and number of venipuncture attempts and catheter redirections were recorded for each catheterization. Placement of the CVC was confirmed by contrast fluoroscopy. After euthanasia, a gross dissection was performed during which a hematoma score was assigned to the catheter insertion site. For each phase, nonlinear least squares estimation was used for learning curve analysis of the UST.

RESULTS Median TTVA, number of venipuncture attempts and catheter redirections, and hematoma score did not differ significantly between the 2 operators for either technique. Median TTVA for the UST (45 seconds) was significantly longer than that for the LMT (7 seconds). Learning curve analysis indicated that 8 and 7 UST catheterizations were required to achieve performance stability in phases 1 and 2, respectively.

CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that the UST was comparable to the LMT for CVC placement in healthy dogs. The extra time required to perform the UST was not clinically relevant. Additional studies evaluating the UST for CVC placement in clinically ill dogs are warranted.

Full access