Abstract

Objective—To identify ventilatory protocols that yielded good image quality for thoracic CT and hemodynamic stability in cats.

Animals—7 healthy cats.

Procedures—Cats were anesthetized and ventilated via 4 randomized protocols (hyperventilation, 20 seconds [protocol 1]; single deep inspiration, positive inspiratory pressure of 15 cm H2O [protocol 2]; recruitment maneuver [protocol 3]; and hyperventilation, 20 seconds with a positive end-expiratory pressure of 5 cm H2O [protocol 4]). Thoracic CT was performed for each protocol; images were acquired during apnea for protocols 1 and 3 and during positive airway pressure for protocols 2 and 4. Heart rate; systolic, mean, and diastolic arterial blood pressures; blood gas values; end-tidal isoflurane concentration; rectal temperature; and measures of atelectasis, total lung volume (TLV), and lung density were determined before and after each protocol.

Results—None of the protocols eliminated atelectasis; the number of lung lobes with atelectasis was significantly greater during protocol 1 than during the other protocols. Lung density and TLV differed significantly among protocols, except between protocols 1 and 3. Protocol 2 TLV exceeded reference values. Arterial blood pressure after each protocol was lower than before the protocols. Mean and diastolic arterial blood pressure were higher after protocol 3 and diastolic arterial blood pressure was higher after protocol 4 than after protocol 2.

Conclusions and Clinical Relevance—Standardization of ventilatory protocols may minimize effects on thoracic CT images and hemodynamic variables. Although atelectasis was still present, ventilatory protocols 3 and 4 provided the best compromise between image quality and hemodynamic stability.

Full access
in American Journal of Veterinary Research