Search Results

You are looking at 1 - 2 of 2 items for :

  • Author or Editor: Fernando Garcia-Pereira x
  • Cardiovascular System x
  • Refine by Access: All Content x
Clear All Modify Search

Abstract

OBJECTIVE To compare cardiac output (CO) measured by use of CT coronary angiography and thermodilution (criterion-referenced standard) at various CO values, record adverse effects, and determine the time needed to measure CO.

ANIMALS 5 healthy purpose-bred Beagles (2 males and 3 females).

PROCEDURES A prospective nonrandomized crossover study was conducted. Dogs were premedicated with butorphanol tartrate (0.2 mg•kg−1, IM). Anesthesia was induced by IV administration of etomidate (1 to 2 mg•kg−1) and midazolam (0.25 mg•kg−1). Orotracheal intubation was performed, and anesthesia was maintained by administration of isoflurane. The CO was determined by use of thermodilution and by use of CT at 3 CO values. Dobutamine was infused at various rates to obtain the 3 CO values.

RESULTS 13 values were obtained and analyzed. The mean ± SD difference between methods was 0.09 ± 0.71 L•min−1 (95% confidence interval [CI], 0.52 to −0.34 L•min−1). Only 1 of 13 values was located on the 100% agreement line (ie, 0 line), 7 of 13 values were located within the 95% CI, and 5 of 13 values were outside the 95% CI.

CONCLUSIONS AND CLINICAL RELEVANCE For this study, there was poor agreement between the 2 methods. The 95% CI interval was 0.52 to −0.34 L•min−1, and 5 of 13 values were outside the 95% CI. Therefore, results for the CT method appeared to be inappropriate for use in making clinical decisions.

Full access
in American Journal of Veterinary Research

Abstract

Objective—To assess the accuracy of an ultrasound velocity dilution cardiac output (UDCO) method, compared with that of the lithium dilution cardiac output (LiDCO) method, for determination of cardiac output (CO) in juvenile horses with experimentally induced hypovolemia.

Animals—12 anesthetized 2- to 6-month-old horses.

Procedures—For each anesthetized horse, CO was determined by the LiDCO and UDCO methods prior to any intervention (baseline state), after withdrawal of approximately 40% of the horse's blood volume (low CO state), after maintenance of hypovolemia and infusion of norepinephrine until mean arterial blood pressure was equal to baseline value (high CO state), and after further infusion of norepinephrine and back-transfusion of withdrawn blood (posttransfusion state). For each of the 4 hemodynamic situations, CO and calculated cardiac index (CI) values were obtained by each method in duplicate (8 pairs of measurements/horse); mean values for each horse and overall mean values across all horses were calculated. Agreement between CI determined by each method (96 paired values) was assessed by Bland-Altman analysis.

Results—For the UDCO method–derived CI measurements among the 12 horses, mean ± SD bias was −4 ± 11.3 mL/kg/min (95% limits of agreement, −26.1 to 18.2 mL/kg/min) and mean relative bias was −10.4 ± 21.5% (95% limits of agreement, −52.6% to 31.8%).

Conclusions and Clinical Relevance—Results indicated that, compared with the LiDCO method, the UDCO method has acceptable clinical usefulness for determination of CO in foals.

Full access
in American Journal of Veterinary Research