Abstract

OBJECTIVE To assess the repeatability and accuracy of polymer replicas of small, medium, and large long bones of small animals fabricated by use of 2 low-end and 2 high-end 3-D printers.

SAMPLE Polymer replicas of a cat femur, dog radius, and dog tibia were fabricated in triplicate by use of each of four 3-D printing methods.

PROCEDURES 3-D renderings of the 3 bones reconstructed from CT images were prepared, and length, width of the proximal aspect, and width of the distal aspect of each CT image were measured in triplicate. Polymer replicas were fabricated by use of a high-end system that relied on jetting of curable liquid photopolymer, a high-end system that relied on polymer extrusion, a triple-nozzle polymer extrusion low-end system, and a dual-nozzle polymer extrusion low-end system. Polymer replicas were scanned by use of a laser-based coordinate measurement machine. Length, width of the proximal aspect, and width of the distal aspect of the scans of replicas were measured and compared with measurements for the 3-D renderings.

RESULTS 129 measurements were collected for 34 replicas (fabrication of 1 large long-bone replica was unsuccessful on each of the 2 low-end printers). Replicas were highly repeatable for all 3-D printers. The 3-D printers overestimated dimensions of large replicas by approximately 1%.

CONCLUSIONS AND CLINICAL RELEVANCE Low-end and high-end 3-D printers fabricated CT-derived replicas of bones of small animals with high repeatability. Replicas were slightly larger than the original bones.

Full access
in American Journal of Veterinary Research

Abstract

OBJECTIVE To investigate in vitro carboplatin release from 6 carrier media.

SAMPLE 6 carboplatin-containing carrier media.

PROCEDURES An in vitro release study was performed with 6 commercially available carrier media: a hemostatic gelatin sponge, a poloxamer copolymer gel, and 2 sizes (3 and 4.8 mm in diameter) of beads molded from each of 2 commercial calcium sulfate products. All carrier media contained 10 mg of carboplatin. Carrier media specimens were placed in 37°C PBS solution for 96 hours. Carboplatin concentrations in PBS solution were measured by use of high-performance liquid chromatography at 15 time points to calculate the amount and proportion of carboplatin released from each specimen.

RESULTS Peak release of carboplatin from the poloxamer copolymer gel and hemostatic gelatin sponge were achieved after 4 and 20 hours, respectively. Maximum release did not differ significantly between the poloxamer copolymer gel and hemostatic gelatin sponge, but both released significantly more carboplatin within 96 hours than did both of the commercial calcium sulfate products. The poloxamer copolymer gel released 99% of the carboplatin, and the hemostatic gelatin sponge released 68.5% of the carboplatin. Peak release of carboplatin from the calcium sulfate beads was not reached within 96 hours.

CONCLUSIONS AND CLINICAL RELEVANCE In this study, carboplatin release from the hemostatic gelatin sponge was incomplete. The poloxamer copolymer gel and hemostatic gelatin sponge released carboplatin rapidly in vitro, whereas calcium sulfate beads did not.

Full access
in American Journal of Veterinary Research

Abstract

Objectives—To describe placement of hinged transarticular external fixation (HTEF) frames and evaluate their ability to protect the primary repair of unstable joints while allowing joint mobility in dogs and cats.

Design—Retrospective study.

Animals—8 cats and 6 dogs.

Procedure—HTEF frames were composed of metal or epoxy connecting rods and a hinge. Measurements of range of motion of affected and contralateral joints and radiographs were made after fixator application and removal.

Results—9 animals (4 cats and 5 dogs) had tarsal and 5 (4 cats and 1 dog) had stifle joint injuries. Treatment duration ranged from 45 to 100 days (median, 57 days). Ranges of motion in affected stifle and tarsal joints were 57% and 72% of control while HTEF was in place and 79% and 84% of control after frame removal. Complications were encountered in 3 cats and 2 dogs and included breakage of pins and connecting rods, hinge loosening, and failure at the hinge-epoxy interface.

Conclusions and Clinical Relevance—HTEF in animals with traumatic joint instability provided adjunctive joint stabilization during healing and protection of the primary repair and maintained joint motion during healing, resulting in early weight bearing of the affected limb. (J Am Vet Med Assoc 2005;227:586–591)

Full access
in Journal of the American Veterinary Medical Association

Abstract

OBJECTIVE

To objectively measure the current demographic makeup of the American College of Veterinary Surgeons (ACVS) diplomates and to develop a survey tool to be used as a metric to measure future changes in the ACVS demographic profile.

SAMPLE

737 ACVS diplomates.

METHODS

A 14-item electronic survey was sent to 2,199 ACVS diplomates between August 25 and September 9, 2021, via email. Survey items included demographic information as well as perceptions about the ACVS and diversity, equity, and inclusion (DEI). Responses were quantitatively and qualitatively analyzed.

RESULTS

The survey response rate was 34% (737/2,199). The median age category among respondents was 45 to 54. The median years in practice as a diplomate was 11 to 15. The majority of respondents identified as white/Caucasian and heterosexual, with male and female respondents being similarly represented. Most respondents identified English as their first language. Few considered themselves first-generation college graduates or identified as disabled. Many respondents considered DEI to be an important initiative to promote in the ACVS.

CLINICAL RELEVANCE

Findings suggested that the majority of ACVS respondents are supportive of DEI efforts. This study also serves as an objective analysis that can be reassessed in the future to determine the success of such initiatives.

Open access
in Journal of the American Veterinary Medical Association

Abstract

OBJECTIVES

To evaluate the effects of the chondrodystrophy-associated FGF4L2 retrogene on intervertebral disc (IVD) calcification and vertebral geometry.

ANIMALS

22 Nova Scotia Duck Tolling Retrievers (NSDTR) with no FGF4L2 retrogene (n = 7, wild-type dogs), 1 retrogene copy (8, heterozygous dogs), or 2 retrogene copies (7, homozygous dogs).

PROCEDURES

Computed tomography (CT) scans of the vertebral column were analyzed using computer-aided design (CAD) software. IVD calcification, vertebral column length, and vertebral geometry of the third cervical (C3), 13th thoracic (T13), and first lumbar (L1) vertebrae were compared.

RESULTS

IVD calcification was not found in wild-type dogs. IVD calcification was more frequent in homozygous dogs than heterozygous (P = .008) or wild-type dogs (P < .001) and in heterozygous dogs compared to wild-type dogs (P < .001). Four IVDs were subclinically herniated in 3 dogs (2 homozygous, 1 heterozygous). Calcified IVD had a greater volume and surface area in heterozygous dogs than homozygous dogs. C3 vertebral canal height-to-width ratio was greater in homozygous dogs than heterozygous dogs (P = .044) and wild-type dogs (P = .010).

CLINICAL RELEVANCE

IVD calcification and vertebral geometry can be analyzed using CAD software. The presence of 1 or 2 FGF4L2 copies in the absence of the FGF4L1 retrogene has an additive effect on the number of calcified IVD and a minor effect on vertebral geometry in NSDTR dogs. Data support the use of FGF4L2 phenotyping to reduce clinical disease in segregating breeds and to monitor the introduction of wild-type alleles into fixed breed populations.

Open access
in American Journal of Veterinary Research

Abstract

OBJECTIVE

Determine whether dogs with well-functioning orthopedic metal implants can develop metal reactivity.

SAMPLE

Client-owned dogs that had tibial plateau leveling osteotomy (TPLO) or total hip replacement (THR) implants for 12 months or more and control dogs with no implants.

PROCEDURES

Lymphocyte transformation testing was performed by exposing peripheral blood lymphocytes to nickel (Ni), chromium (Cr), cobalt (Co), or a combination of these metals. Lymphocyte proliferation was assessed with flow cytometry. Lymphocyte stimulation indexes (SIs) were calculated. A SI > 2 was considered reactive. Median SIs of dogs in response to metal exposure were compared statistically.

RESULTS

Samples from 10 dogs with TPLO, 12 dogs with THR, and 7 control dogs were analyzed. Six dogs out of 22 with metal implants had a reactive SI to 1 or more metals, while 2 of 7 control dogs had a SI > 2 when exposed to nickel only. When all metals were considered, no differences in metal reactivity were found between TPLO, THR, and control groups.

CLINICAL RELEVANCE

Metal reactivity is present in dogs and can be identified using lymphocyte transformation testing. Reactivity to Ni is present in dogs with and without metal implants. Reactivity to Co and Cr occurs in some dogs with metal implants.

Open access
in American Journal of Veterinary Research

Abstract

OBJECTIVE

To compare osteoarthritis scores assigned through radiographic evaluation of 18 anatomic regions in the elbow joint with scores assigned through evaluation of 3-D maximum intensity projection (MIP), 3-D surface rendering (TSR), and multiplanar reconstructed (MPR) CT images, and to evaluate intraobserver and interobserver agreement of radiographic and CT scoring.

SAMPLE

Radiographic and CT images of 39 elbow joints in 20 dogs.

PROCEDURES

Images were anonymized and graded independently by 5 observers. One observer graded 12 elbow joints 3 times. Intraobserver consistency and repeatability, interobserver agreement, consistency among methods, and bias between methods were calculated.

RESULTS

The most severe changes were observed at the proximal aspect of the anconeal process, and the medial and cranial aspects of the medial coronoid process. Intraobserver consistency was moderate or better for 11/16 regions with MIP images, 11/16 regions with TSR images, 17/18 regions with MPR images, and 14/18 regions with radiographic images. Interobserver agreement was moderate or better for 5/16 regions with MIP images, 9/16 regions with TSR images, 12/18 regions with MPR images, and 6/18 regions with radiographic images. Mean scores from CT-based methods were higher than mean radiographic scores.

CLINICAL RELEVANCE

Assessments of osteoarthritis severity in the elbow joints of dogs obtained by examining radiographic images were generally consistent with assessments obtained by examining CT scans. MPR scores were more consistent and more comparable to radiographic scores than were MIP or TSR scores.

Open access
in American Journal of Veterinary Research