Utility of commercially available reagent test strips for estimation of blood urea nitrogen concentration and detection of azotemia in pet rabbits (Oryctolagus cuniculus) and ferrets (Mustela putorius furo)

Megan L. Cabot 1Clinic for the Rehabilitation of Wildlife, 3883 Sanibel Captiva Rd, Sanibel Island, FL 33957.

Search for other papers by Megan L. Cabot in
Current site
Google Scholar
PubMed
Close
 DVM
,
David Eshar 2Department of Clinical Sciences, College of Veterinary Medicine, Kansas State University, Manhattan, KS 66506.

Search for other papers by David Eshar in
Current site
Google Scholar
PubMed
Close
 DVM
, and
Hugues Beaufrère 3Department of Clinical Sciences, Ontario Veterinary College, University of Guelph, Guelph, ON N1G 2W1, Canada.

Search for other papers by Hugues Beaufrère in
Current site
Google Scholar
PubMed
Close
 DVM, PhD

Abstract

OBJECTIVE

To evaluate the utility of commercially available reagent test strips for estimation of BUN concentration and detection of azotemia in pet rabbits (Oryctolagus cuniculus) and ferrets (Mustela putorius furo).

SAMPLE

65 blood samples from 53 rabbits and 71 blood samples from 50 ferrets of various health statuses.

PROCEDURES

BUN concentrations were measured with a clinical laboratory biochemical analyzer and estimated with a reagent test strip. Results obtained with both methods were assigned to a BUN category (range, 1 to 4; higher categories corresponded to higher BUN concentrations). Samples with a biochemical analyzer BUN concentration ≥ 27 mg/dL (rabbits) or ≥ 41 mg/dL (ferrets) were considered azotemic. A test strip BUN category of 3 or 4 (rabbits) or 4 (ferrets) was considered positive for azotemia.

RESULTS

Test strip and biochemical analyzer BUN categories were concordant for 46 of 65 (71%) rabbit blood samples and 58 of 71 (82%) ferret blood samples. Sensitivity, specificity, and accuracy of the test strips for detection of azotemia were 92%, 79%, and 82%, respectively, for rabbit blood samples and 80%, 100%, and 96%, respectively, for ferret blood samples.

CONCLUSIONS AND CLINICAL RELEVANCE

Test strips provided reasonable estimates of BUN concentration but, for rabbits, were more appropriate for ruling out than for ruling in azotemia because of false-positive test strip results. False-negative test strip results for azotemia were more of a concern for ferrets than rabbits. Testing with a biochemical analyzer remains the gold standard for measurement of BUN concentration and detection of azotemia in rabbits and ferrets.

Abstract

OBJECTIVE

To evaluate the utility of commercially available reagent test strips for estimation of BUN concentration and detection of azotemia in pet rabbits (Oryctolagus cuniculus) and ferrets (Mustela putorius furo).

SAMPLE

65 blood samples from 53 rabbits and 71 blood samples from 50 ferrets of various health statuses.

PROCEDURES

BUN concentrations were measured with a clinical laboratory biochemical analyzer and estimated with a reagent test strip. Results obtained with both methods were assigned to a BUN category (range, 1 to 4; higher categories corresponded to higher BUN concentrations). Samples with a biochemical analyzer BUN concentration ≥ 27 mg/dL (rabbits) or ≥ 41 mg/dL (ferrets) were considered azotemic. A test strip BUN category of 3 or 4 (rabbits) or 4 (ferrets) was considered positive for azotemia.

RESULTS

Test strip and biochemical analyzer BUN categories were concordant for 46 of 65 (71%) rabbit blood samples and 58 of 71 (82%) ferret blood samples. Sensitivity, specificity, and accuracy of the test strips for detection of azotemia were 92%, 79%, and 82%, respectively, for rabbit blood samples and 80%, 100%, and 96%, respectively, for ferret blood samples.

CONCLUSIONS AND CLINICAL RELEVANCE

Test strips provided reasonable estimates of BUN concentration but, for rabbits, were more appropriate for ruling out than for ruling in azotemia because of false-positive test strip results. False-negative test strip results for azotemia were more of a concern for ferrets than rabbits. Testing with a biochemical analyzer remains the gold standard for measurement of BUN concentration and detection of azotemia in rabbits and ferrets.