• 1. Cohen TA, Nelson RW, Kass PH, et al. Evaluation of six portable blood glucose meters for measuring blood glucose concentration in dogs. J Am Vet Med Assoc 2009; 235: 276280.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 2. Johnson BM, Fry MM, Flatland B, et al. Comparison of a human portable blood glucose meter, veterinary portable blood glucose meter, and automated chemistry analyzer for measurement of blood glucose concentrations in dogs. J Am Vet Med Assoc 2009; 235: 13091313.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 3. Zini E, Moretti S, Tschuor F, et al. Evaluation of a new portable glucose meter designed for the use in cats. Schweiz Arch Tierheilkd 2009; 151: 448451.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 4. Coldman MF, Good W. The distribution of sodium, potassium and glucose in the blood of some mammals. Comp Biochem Physiol 1967; 21: 201206.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 5. Paul AE, Shiel RE, Juvet F, et al. Effect of hematocrit on accuracy of two point-of-care glucometers for use in dogs. Am J Vet Res 2011; 72: 12041208.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 6. Solnica B, Skupien J, Kusnierz-Cabala B, et al. The effect of hematocrit on the results of measurements using glucose meters based on different techniques. Clin Chem Lab Med 2012; 50: 361365.

    • Search Google Scholar
    • Export Citation
  • 7. Jamaluddin FA, Gunavathy M, Yean C, et al. Variability of point-of-care testing blood glucometers versus the laboratory reference method in a tertiary teaching hospital. Asian Biomed 2012; 6: 6774.

    • Search Google Scholar
    • Export Citation
  • 8. Tang Z, Lee JH, Sutton D, et al. Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing. Arch Pathol Lab Med 2000; 124: 11351140.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 9. Barreau PB, Buttery JE. The effect of the haematocrit value on the determination of glucose levels by the reagent-strip methods. Med J Aust 1987; 147: 286288.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 10. Pidcoke HF, Wade CE, Mann EA, et al. Anemia causes hypoglycemia in intensive care unit patients due to error in single-channel glucometers: methods of reducing patient risk. Crit Care Med 2010; 38: 471476.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 11. Hussain K, Sharief N. The inaccuracy of venous and capillary blood glucose measurement using reagent strips in the newborn period and the effect of haematocrit. Early Hum Dev 2000; 57: 111121.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 12. Ginsberg BH. Factors affecting blood glucose monitoring: sources of errors in measurement. J Diabetes Sci Technol 2009; 3: 903913.

  • 13. AlphaTRAK 2 [package insert]. Abbott Park, Ill: Abbott Laboratories, 2012.

  • 14. Clarke WL, Cox D, Gonder-Frederick LA, et al. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 1987; 10: 622628.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 15. Parkes JL, Slatin SL, Pardo S, et al. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care 2000; 23: 11431148.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 16. Reineke EL, Fletcher DJ, King LG, et al. Accuracy of a continuous glucose monitoring system in dogs and cats with diabetic ketoacidosis. J Vet Emerg Crit Care (San Antonio) 2010; 20: 303312.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 17. Karon BS, Griesmann L, Scott R, et al. Evaluation of the impact of hematocrit and other interference on the accuracy of hospital-based glucose meters. Diabetes Technol Ther 2008; 10: 111120.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 18. Louie RF, Tang Z, Sutton DV, et al. Point-of-care glucose testing: effects of critical care variables, influence of reference instruments, and a modular glucose meter design. Arch Pathol Lab Med 2000; 124: 257266.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 19. Tonyushkina K, Nichols JH. Glucose meters: a review of technical challenges to obtaining accurate results. J Diabetes Sci Tech 2009; 3: 971980.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 20. Tang Z, Du X, Louie R, et al. Effects of drugs on glucose measurements with handheld glucose meters and a portable glucose analyzer. Am J Clin Pathol 2000; 113: 7586.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 21. Mann EA, Salinas J, Pidcoke HF, et al. Error rates resulting from anemia can be corrected in multiple commonly used point-of-care glucometers. J Trauma 2008; 64: 1520.

    • Search Google Scholar
    • Export Citation
  • 22. Girouard J, Forest J, Massé J, et al. Multicenter evaluation of the Glucometer Elite XL meter, an instrument specifically designed for use with neonates. Diabetes Care 2000; 23: 11491153.

    • Crossref
    • Search Google Scholar
    • Export Citation

Advertisement

Formulation and validation of a predictive model to correct blood glucose concentrations obtained with a veterinary point-of-care glucometer in hemodiluted and hemoconcentrated canine blood samples

Selena L. LaneDepartment of Small Animal Medicine and Surgery, College of Veterinary Medicine, University of Georgia, Athens, GA 30602.

Search for other papers by Selena L. Lane in
Current site
Google Scholar
PubMed
Close
 DVM
,
Amie KoenigDepartment of Small Animal Medicine and Surgery, College of Veterinary Medicine, University of Georgia, Athens, GA 30602.

Search for other papers by Amie Koenig in
Current site
Google Scholar
PubMed
Close
 DVM
, and
Benjamin M. BrainardDepartment of Small Animal Medicine and Surgery, College of Veterinary Medicine, University of Georgia, Athens, GA 30602.

Search for other papers by Benjamin M. Brainard in
Current site
Google Scholar
PubMed
Close
 VMD

Abstract

Objective—To determine the effect of PCV on veterinary point-of-care (POC) glucometer measurements in canine blood samples and develop a formula to correct the glucose concentration as measured by a point-of-care glucometer (POCgluc) given a known PCV.

Design—Experimental and prospective study.

Samples—Blood samples from 6 healthy dogs and from 30 hospitalized dogs.

Procedures—60 mL of heparinized blood was obtained from each of 6 healthy dogs. Samples were processed into packed RBCs and plasma. Packed RBCs were resuspended with plasma to achieve a range of PCVs from 0% to 94%. Duplicate POCgluc and PCV measurements were obtained for each dilution; following POCgluc measurements, plasma samples were analyzed for glucose concentration by a clinical laboratory biochemical analyzer (LABgluc). A correction formula for POCgluc was developed. Measurements of POCgluc, PCV, and LABgluc were also determined from blood samples of 30 dogs admitted to the veterinary teaching hospital.

Results—Values of LABgluc for each sample were similar at any PCV. As PCV decreased, POCgluc was falsely increased; as PCV increased, POCgluc was falsely decreased, compared with LABgluc. The absolute difference between POCgluc and LABgluc increased as the PCV changed from 50%. Compared with POCgluc, the corrected POCgluc had a significantly improved correlation with LABgluc, which was also reflected in improvements in Clarke and consensus error grid analyses.

Conclusions and Clinical Relevance—Results indicated that in dogs with hemodilution or hemoconcentration, POCgluc did not reflect actual patient glucose concentrations. Use of a correction formula reduced this error. Corrected POCgluc data had strong, significant correlations with LABgluc data.

Abstract

Objective—To determine the effect of PCV on veterinary point-of-care (POC) glucometer measurements in canine blood samples and develop a formula to correct the glucose concentration as measured by a point-of-care glucometer (POCgluc) given a known PCV.

Design—Experimental and prospective study.

Samples—Blood samples from 6 healthy dogs and from 30 hospitalized dogs.

Procedures—60 mL of heparinized blood was obtained from each of 6 healthy dogs. Samples were processed into packed RBCs and plasma. Packed RBCs were resuspended with plasma to achieve a range of PCVs from 0% to 94%. Duplicate POCgluc and PCV measurements were obtained for each dilution; following POCgluc measurements, plasma samples were analyzed for glucose concentration by a clinical laboratory biochemical analyzer (LABgluc). A correction formula for POCgluc was developed. Measurements of POCgluc, PCV, and LABgluc were also determined from blood samples of 30 dogs admitted to the veterinary teaching hospital.

Results—Values of LABgluc for each sample were similar at any PCV. As PCV decreased, POCgluc was falsely increased; as PCV increased, POCgluc was falsely decreased, compared with LABgluc. The absolute difference between POCgluc and LABgluc increased as the PCV changed from 50%. Compared with POCgluc, the corrected POCgluc had a significantly improved correlation with LABgluc, which was also reflected in improvements in Clarke and consensus error grid analyses.

Conclusions and Clinical Relevance—Results indicated that in dogs with hemodilution or hemoconcentration, POCgluc did not reflect actual patient glucose concentrations. Use of a correction formula reduced this error. Corrected POCgluc data had strong, significant correlations with LABgluc data.