Comparison of pH and refractometry index with calcium concentrations in preparturient mammary gland secretions of mares

Kenji Korosue Hidaka Training and Research Center, Japan Racing Association, 535-13 Aza-Nishicha, Urakawa-cho, Urakawa-gun, Hokkaido 057-0171, Japan.

Search for other papers by Kenji Korosue in
Current site
Google Scholar
PubMed
Close
 DVM
,
Harutaka Murase Hidaka Training and Research Center, Japan Racing Association, 535-13 Aza-Nishicha, Urakawa-cho, Urakawa-gun, Hokkaido 057-0171, Japan.

Search for other papers by Harutaka Murase in
Current site
Google Scholar
PubMed
Close
 DVM
,
Fumio Sato Hidaka Training and Research Center, Japan Racing Association, 535-13 Aza-Nishicha, Urakawa-cho, Urakawa-gun, Hokkaido 057-0171, Japan.

Search for other papers by Fumio Sato in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
,
Mutsuki Ishimaru Hidaka Training and Research Center, Japan Racing Association, 535-13 Aza-Nishicha, Urakawa-cho, Urakawa-gun, Hokkaido 057-0171, Japan.

Search for other papers by Mutsuki Ishimaru in
Current site
Google Scholar
PubMed
Close
 DVM
,
Yasumitsu Kotoyori Equine Research Institute, Japan Racing Association, 321-4 Tokami-cho, Utsunomiya-city, Tochigi Prefecture 320-0856, Japan.

Search for other papers by Yasumitsu Kotoyori in
Current site
Google Scholar
PubMed
Close
 DVM
,
Koji Tsujimura Epizootic Research Center, Equine Research Institute, Japan Racing Association, 1400-4 Shiba, Shimotsuke-city, Tochigi Prefecture 320-0412, Japan.

Search for other papers by Koji Tsujimura in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
, and
Yasuo Nambo Hidaka Training and Research Center, Japan Racing Association, 535-13 Aza-Nishicha, Urakawa-cho, Urakawa-gun, Hokkaido 057-0171, Japan.

Search for other papers by Yasuo Nambo in
Current site
Google Scholar
PubMed
Close
 DVM, PhD

Abstract

Objective—To test the usefulness of measuring pH and refractometry index, compared with measuring calcium carbonate concentration, of preparturient mammary gland secretions for predicting parturition in mares.

Design—Evaluation study.

Animals—27 pregnant Thoroughbred mares.

Procedures—Preparturient mammary gland secretion samples were obtained once or twice daily 10 days prior to foaling until parturition. The samples were analyzed for calcium carbonate concentration with a water hardness kit (151 samples), pH with pH test paper (222 samples), and refractometry index with a Brix refractometer (214 samples). The sensitivity, specificity, and positive and negative predictive values for each test were calculated for evaluation of predicting parturition.

Results—The PPV within 72 hours and the NPV within 24 hours for calcium carbonate concentration determination (standard value set to 400 μg/g) were 93.8% and 98.3%, respectively. The PPV within 72 hours and the NPV within 24 hours for the pH test (standard value set at 6.4) were 97.9% and 99.4%, respectively. The PPV within 72 hours and the NPV within 24 hours for the Brix test (standard value set to 20%) were 73.2% and 96.5%, respectively.

Conclusions and Clinical Relevance—Results suggested that the pH test with the standard value set at a pH of 6.4 would be useful in the management of preparturient mares by predicting when mares are not ready to foal. This was accomplished with equal effectiveness of measuring calcium carbonate concentration with a water hardness kit.

Abstract

Objective—To test the usefulness of measuring pH and refractometry index, compared with measuring calcium carbonate concentration, of preparturient mammary gland secretions for predicting parturition in mares.

Design—Evaluation study.

Animals—27 pregnant Thoroughbred mares.

Procedures—Preparturient mammary gland secretion samples were obtained once or twice daily 10 days prior to foaling until parturition. The samples were analyzed for calcium carbonate concentration with a water hardness kit (151 samples), pH with pH test paper (222 samples), and refractometry index with a Brix refractometer (214 samples). The sensitivity, specificity, and positive and negative predictive values for each test were calculated for evaluation of predicting parturition.

Results—The PPV within 72 hours and the NPV within 24 hours for calcium carbonate concentration determination (standard value set to 400 μg/g) were 93.8% and 98.3%, respectively. The PPV within 72 hours and the NPV within 24 hours for the pH test (standard value set at 6.4) were 97.9% and 99.4%, respectively. The PPV within 72 hours and the NPV within 24 hours for the Brix test (standard value set to 20%) were 73.2% and 96.5%, respectively.

Conclusions and Clinical Relevance—Results suggested that the pH test with the standard value set at a pH of 6.4 would be useful in the management of preparturient mares by predicting when mares are not ready to foal. This was accomplished with equal effectiveness of measuring calcium carbonate concentration with a water hardness kit.