• 1.

    Top 10 causes of death. World Health Organization. December 9, 2020. Accessed Jan 10, 2021. https://www.who.int/news-room/fact-sheets/detail/the-top-10-causes-of-death

    • Search Google Scholar
    • Export Citation
  • 2.

    Whelton PK, Carey RM, Aronow WS, et al. 2017 ACC/AHA/AAPA/ABC/ACPM/AGS/APhA/ASH/ASPC/NMA/PCNA guideline for the prevention, detection, evaluation, and management of high blood pressure in adults: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Hypertension. 2018;71(6):12691324.

    • Search Google Scholar
    • Export Citation
  • 3.

    Acierno MJ, Brown S, Coleman AE, et al. ACVIM consensus statement: guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats. J Vet Intern Med. 2018;32(6):18031822.

    • Search Google Scholar
    • Export Citation
  • 4.

    Seiler BM, Dick EJ Jr, Guardado-Mendoza R, et al. Spontaneous heart disease in the adult chimpanzee (Pan troglodytes). J Med Primatol. 2009;38(1):5158.

    • Search Google Scholar
    • Export Citation
  • 5.

    Laurence H, Kumar S, Owston MA, Lanford RE, Hubbard GB, Dick EJ Jr. Natural mortality and cause of death analysis of the captive chimpanzee ((Pan troglodytes): a 35-year review. J Med Primatol. 2017;46(3):106115.

    • Search Google Scholar
    • Export Citation
  • 6.

    Kumar S, Laurence H, Owston MA, et al. Natural pathology of the captive chimpanzee (Pan troglodytes): a 35-year review. J Med Primatol. 2017;46(5):271290.

    • Search Google Scholar
    • Export Citation
  • 7.

    Varki N, Anderson D, Herndon JG, et al. Heart disease is common in humans and chimpanzees, but is caused by different pathological processes. Evol Appl. 2009;2(1):101112.

    • Search Google Scholar
    • Export Citation
  • 8.

    Ely JJ, Zavaskis T, Lammey ML. Hypertension increases with aging and obesity in chimpanzees (Pan troglodytes). Zoo Biol. 2013;32(1):7987.

    • Search Google Scholar
    • Export Citation
  • 9.

    Muntner P, Shimbo D, Carey RM, et al. Measurement of blood pressure in humans: a scientific statement from the American Heart Association. Hypertension. 2019;73(5):e35e66.

    • Search Google Scholar
    • Export Citation
  • 10.

    Bartels K, Esper SA, Thiele RH. Blood pressure monitoring for the anesthesiologist: a practical review. Anesth Analg. 2016;122(6):18661879.

    • Search Google Scholar
    • Export Citation
  • 11.

    Deflandre CJ, Hellebrekers LJ. Clinical evaluation of the Surgivet V60046, a non invasive blood pressure monitor in anaesthetized dogs. Vet Anaesth Analg. 2008;35(1):1321.

    • Search Google Scholar
    • Export Citation
  • 12.

    Elliott P, Walker LL, Little MP, et al. Change in salt intake affects blood pressure of chimpanzees: implications for human populations. Circulation. 2007;116(14):15631568.

    • Search Google Scholar
    • Export Citation
  • 13.

    Ely JJ, Zavaskis T, Lammey ML, Lee RD. Blood pressure reference intervals for healthy adult chimpanzees (Pan troglodytes). J Med Primatol. 2011;40(3):171180.

    • Search Google Scholar
    • Export Citation
  • 14.

    Lehman LW, Saeed M, Talmor D, Mark R, Malhotra A. Methods of blood pressure measurement in the ICU. Crit Care Med. 2013;41(1):3440.

  • 15.

    Acierno MJ, Fauth E, Mitchell MA, da Cunha A. Measuring the level of agreement between directly measured blood pressure and pressure readings obtained with a veterinary-specific oscillometric unit in anesthetized dogs. J Vet Emerg Crit Care (San Antonio). 2013;23(1):3740.

    • Search Google Scholar
    • Export Citation
  • 16.

    Zwijnenberg RJ, del Rio CL, Cobb RM, Ueyama Y, Muir WM. Evaluation of oscillometric and vascular access port arterial blood pressure measurement techniques versus implanted telemetry in anesthetized cats. Am J Vet Res. 2011;72(8):10151021.

    • Search Google Scholar
    • Export Citation
  • 17.

    Giguère S, Knowles HA Jr, Valverde A, Bucki E, Young L. Accuracy of indirect measurement of blood pressure in neonatal foals. J Vet Intern Med. 2005;19(4):571576.

    • Search Google Scholar
    • Export Citation
  • 18.

    Harvey L, Knowles T, Murison PJ. Comparison of direct and Doppler arterial blood pressure measurements in rabbits during isoflurane anaesthesia. Vet Anaesth Analg. 2012;39(2):174184.

    • Search Google Scholar
    • Export Citation
  • 19.

    Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17(4):571582.

    • Search Google Scholar
    • Export Citation
  • 20.

    Ashley AL, Smith CK, Köster LS, Mulreany L, Cushing AC. Echocardiography and direct arterial blood pressure measurement in captive chimpanzees (Pan troglodytes) during two phases of an anesthetic protocol. J Zoo Wildl Med. 2021;52(2):479489.

    • Search Google Scholar
    • Export Citation
  • 21.

    Drynan EA, Raisis AL. Comparison of invasive versus noninvasive blood pressure measurements before and after hemorrhage in anesthetized Greyhounds using the Surgivet V9203. J Vet Emerg Crit Care (San Antonio). 2013;23(5):523531.

    • Search Google Scholar
    • Export Citation
  • 22.

    Garofalo NA, Teixeira Neto FJ, Alvaides RK, de Oliveira FA, Pignaton W, Pinheiro RT. Agreement between direct, oscillometric and Doppler ultrasound blood pressures using three different cuff positions in anesthetized dogs. Vet Anaesth Analg. 2012;39(4):324334.

    • Search Google Scholar
    • Export Citation
  • 23.

    Schwid HA, Taylor LA, Smith NT. Computer model analysis of the radial artery pressure waveform. J Clin Monit. 1987;3(4):220228.

  • 24.

    Shih A, Robertson S, Vigani A, da Cunha A, Pablo L, Bandt C. Evaluation of an indirect oscillometric blood pressure monitor in normotensive and hypotensive anesthetized dogs. J Vet Emerg Crit Care (San Antonio). 2010;20(3):313318.

    • Search Google Scholar
    • Export Citation
  • 25.

    Bosiack AP, Mann FA, Dodam JR, Wagner-Mann CC, Branson KR. Comparison of ultrasonic Doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs. J Vet Emerg Crit Care (San Antonio). 2010;20(2):207215.

    • Search Google Scholar
    • Export Citation
  • 26.

    McMurphy RM, Stoll MR, McCubrey R. Accuracy of an oscillometric blood pressure monitor during phenylephrine-induced hypertension in dogs. Am J Vet Res. 2006;67(9):15411545.

    • Search Google Scholar
    • Export Citation
  • 27.

    Tearney CC, Guedes AG, Brosnan RJ. Equivalence between invasive and oscillometric blood pressures at different anatomic locations in healthy normotensive anaesthetised horses. Equine Vet J. 2016;48(3):357361.

    • Search Google Scholar
    • Export Citation

Agreement between oscillometric and direct blood pressure measurements in anesthetized captive chimpanzees (Pan troglodytes)

View More View Less
  • 1 From the Department of Small Animal Clinical Sciences (Smith, Cushing) and Office of Information and Technology (Zhu), College of Veterinary Medicine, University of Tennessee, Knoxville, TN 37996; and The Chattanooga Zoo, Chattanooga, TN 37404 (Ashley).

Abstract

OBJECTIVE

To evaluate the level of agreement (LOA) between direct and oscillometric blood pressure (BP) measurements and the ability of oscillometric measurements to accurately detect hypotension in anesthetized chimpanzees (Pan troglodytes).

ANIMALS

8 captive, adult chimpanzees.

PROCEDURES

During prescheduled annual examinations, each chimpanzee underwent general anesthesia and patient monitoring for their examination, echocardiography for a concurrent study, and measurement of direct BP with the use of tibial artery catheterization and oscillometry with the use of a cuff placed around a brachium and a cuff placed around the second digit of the contralateral forelimb for the present study. Bland-Altman plots were generated to compare results for direct and oscillometric BP measurements. Mean bias and 95% LOAs were calculated for oscillometric measurements of systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and mean arterial pressure (MAP) for each cuff site. Sensitivity and specificity in detecting hypotension were also determined for each cuff site.

RESULTS

There were 74 paired direct and brachial oscillometric measurements of each, SAP, MAP, and DAP and 66 paired direct and digit oscillometric measurements of each, SAP, MAP, and DAP. Only brachial oscillometric measurements of MAP had adequate sensitivity (78%) and specificity (95%) to accurately detect hypotension, and this technique also had the least mean bias (0.8 mm Hg; 95% LOA, –29 to 31 mm Hg).

CONCLUSIONS AND CLINICAL RELEVANCE

Results indicated that brachial oscillometric measurement of MAP provided reasonable agreement with tibial arterial direct MAP measurement and performed well in diagnosing hypotension in anesthetized chimpanzees.

Abstract

OBJECTIVE

To evaluate the level of agreement (LOA) between direct and oscillometric blood pressure (BP) measurements and the ability of oscillometric measurements to accurately detect hypotension in anesthetized chimpanzees (Pan troglodytes).

ANIMALS

8 captive, adult chimpanzees.

PROCEDURES

During prescheduled annual examinations, each chimpanzee underwent general anesthesia and patient monitoring for their examination, echocardiography for a concurrent study, and measurement of direct BP with the use of tibial artery catheterization and oscillometry with the use of a cuff placed around a brachium and a cuff placed around the second digit of the contralateral forelimb for the present study. Bland-Altman plots were generated to compare results for direct and oscillometric BP measurements. Mean bias and 95% LOAs were calculated for oscillometric measurements of systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and mean arterial pressure (MAP) for each cuff site. Sensitivity and specificity in detecting hypotension were also determined for each cuff site.

RESULTS

There were 74 paired direct and brachial oscillometric measurements of each, SAP, MAP, and DAP and 66 paired direct and digit oscillometric measurements of each, SAP, MAP, and DAP. Only brachial oscillometric measurements of MAP had adequate sensitivity (78%) and specificity (95%) to accurately detect hypotension, and this technique also had the least mean bias (0.8 mm Hg; 95% LOA, –29 to 31 mm Hg).

CONCLUSIONS AND CLINICAL RELEVANCE

Results indicated that brachial oscillometric measurement of MAP provided reasonable agreement with tibial arterial direct MAP measurement and performed well in diagnosing hypotension in anesthetized chimpanzees.