Point shear wave elastography of the liver in healthy adult cats

Saechol Park College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul 08826, Republic of Korea.

Search for other papers by Saechol Park in
Current site
Google Scholar
PubMed
Close
 DVM, MS
,
Jeongwoo Choi College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul 08826, Republic of Korea.

Search for other papers by Jeongwoo Choi in
Current site
Google Scholar
PubMed
Close
 DVM
,
Kyeonga Kim College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul 08826, Republic of Korea.

Search for other papers by Kyeonga Kim in
Current site
Google Scholar
PubMed
Close
 DVM
,
Donghyun Oh College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul 08826, Republic of Korea.

Search for other papers by Donghyun Oh in
Current site
Google Scholar
PubMed
Close
 DVM
,
Junghee Yoon College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul 08826, Republic of Korea.

Search for other papers by Junghee Yoon in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
, and
Mincheol Choi College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul 08826, Republic of Korea.

Search for other papers by Mincheol Choi in
Current site
Google Scholar
PubMed
Close
 DVM, PhD

Abstract

OBJECTIVE

To evaluate stiffness of the liver parenchyma in healthy adult cats by means of point shear wave elastography (PSWE).

ANIMALS

18 client-owned adult (1- to 6-year-old) healthy cats.

PROCEDURES

Echogenicity and echotexture of the liver parenchyma were assessed by means of conventional B-mode ultrasonography. The shear wave velocity (Vs) of the right and left portions of the liver were measured by means of PSWE.

RESULTS

B-mode ultrasonography revealed no abnormalities in echotexture or echogenicity of the liver parenchyma in any cat. Mean (95% CI) Vs in the liver parenchyma was 1.46 m/s (1.36 to 1.55 m/s) for the right portion, 1.36 m/s (1.26 to 1.47 m/s) for the left portion, and 1.43 m/s (1.35 to 1.51 m/s) overall. The difference in mean Vs between the 2 portions of the liver was significant. No significant correlation was found between Vs and body weight or between Vs and the depth at which this variable was measured.

CONCLUSIONS AND CLINICAL RELEVANCE

Quantitative PSWE of the liver was feasible in healthy adult cats. The obtained values for Vs may be useful for interpretation of and comparison with values measured in cats with liver disease. Additional research is needed to explore the potential usefulness of PSWE for diagnostic purposes.

Abstract

OBJECTIVE

To evaluate stiffness of the liver parenchyma in healthy adult cats by means of point shear wave elastography (PSWE).

ANIMALS

18 client-owned adult (1- to 6-year-old) healthy cats.

PROCEDURES

Echogenicity and echotexture of the liver parenchyma were assessed by means of conventional B-mode ultrasonography. The shear wave velocity (Vs) of the right and left portions of the liver were measured by means of PSWE.

RESULTS

B-mode ultrasonography revealed no abnormalities in echotexture or echogenicity of the liver parenchyma in any cat. Mean (95% CI) Vs in the liver parenchyma was 1.46 m/s (1.36 to 1.55 m/s) for the right portion, 1.36 m/s (1.26 to 1.47 m/s) for the left portion, and 1.43 m/s (1.35 to 1.51 m/s) overall. The difference in mean Vs between the 2 portions of the liver was significant. No significant correlation was found between Vs and body weight or between Vs and the depth at which this variable was measured.

CONCLUSIONS AND CLINICAL RELEVANCE

Quantitative PSWE of the liver was feasible in healthy adult cats. The obtained values for Vs may be useful for interpretation of and comparison with values measured in cats with liver disease. Additional research is needed to explore the potential usefulness of PSWE for diagnostic purposes.

Contributor Notes

Address correspondence to Dr. Mincheol Choi (mcchoi@snu.ac.kr).
  • 1.

    Sigrist RMS, Liau J, Kaffas AE, et al. Ultrasound elastography: review of techniques and clinical applications. Theranostics 2017;7:13031329.

  • 2.

    White J, Gay J, Farnsworth R, et al. Ultrasound elastography of the liver, spleen, and kidneys in clinically normal cats. Vet Radiol Ultrasound 2014;55:428434.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 3.

    Carvalho CF, Chammas MC. Elastography—a new technology associated with ultrasonography. Clin Vet (Milano) 2013;18:6270.

  • 4.

    Chang JM, Won JK, Lee KB, et al. Comparison of shear-wave and strain ultrasound elastography in the differentiation of benign and malignant breast lesions. AJR Am J Roentgenol 2013;201:W347W356.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 5.

    Ferraioli G, Tinelli C, Zicchetti M, et al. Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity. Eur J Radiol 2012;81:31023106.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 6.

    Guzmán-Aroca F, Reus M, Berna-Serna JD, et al. Reproducibility of shear wave velocity measurements by acoustic radiation force impulse imaging of the liver. J Ultrasound Med 2011;30:975979.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 7.

    Yoneda M, Suzuki K, Kato S, et al. Nonalcoholic fatty liver disease: US-based acoustic radiation force impulse elastography. Radiology 2010;256:640647.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 8.

    Tamura M, Ohta H, Shimbo G, et al. Usefulness of noninvasive shear wave elastography for the assessment of hepatic fibrosis in dogs. J Vet Intern Med 2019;33:20672074.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 9.

    Feliciano MAR, Maronezi MC, Pavan L, et al. ARFI elastography as a complementary diagnostic method for mammary neoplasia in female dogs—preliminary results. J Small Anim Pract 2014;55:504508.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 10.

    Feliciano MAR, Maronezi MC, Simoes APR, et al. Acoustic radiation force impulse (ARFI) elastography of testicular disorders in dogs: preliminary results. Arq Bras Med Vet Zootec 2016;68:283291.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 11.

    Feliciano MAR, Maronezi MC, Crivellenti LZ, et al. Acoustic radiation force impulse (ARFI) elastography of the spleen in healthy adult cats – a preliminary study. J Small Anim Pract 2015;56:180183.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 12.

    Garcia PHS, Feliciano MAR, Carvalho CF, et al. Acoustic radiation force impulse (ARFI) elastography of kidneys in healthy adult cats: preliminary results. J Small Anim Pract 2015;56:505509.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 13.

    Feliciano MAR, Maronezi MC, Brito MBS, et al. Doppler and elastography as complementary diagnostic methods for mammary neoplasm female cats. Arq Bras Med Vet Zootec 2015;67:935939.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 14.

    Brito MBS, Feliciano MAR, Coutinho LN, et al. ARFI elastography of healthy adults felines testes. Acta Sci Vet 2015;43:1303.

  • 15.

    Thanaboonnipat C, Sutayatram S, Buranakarl C, et al. Renal shear wave elastography and urinary procollagen type III amino-terminal propeptide (uPIIINP) in feline chronic kidney disease. BMC Vet Res 2019;15:54.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 16.

    Madhok R, Tapasvi C, Prasad U, et al. Acoustic radiation force impulse imaging of the liver: measurement of the normal mean values of the shearing wave velocity in a healthy liver. J Clin Diagn Res 2013;7:3942.

    • Search Google Scholar
    • Export Citation
  • 17.

    Boursier J, Zarski JP, de Ledinghen V, et al. Determination of reliability criteria for liver stiffness evaluation by transient elastography. Hepatology 2013;57:11821191.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 18.

    Feeney DA, Anderson KL, Ziegler LE, et al. Statistical relevance of ultrasonographic criteria in the assessment of diffuse liver disease in dogs and cats. Am J Vet Res 2008;69:212221.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 19.

    Bai M, Du L, Gu J, et al. Virtual touch tissue quantification using acoustic radiation force impulse technology: initial clinical experience with solid breast masses. J Ultrasound Med 2012;31:289294.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 20.

    Mattoon JS, Nyland TG. Small animal diagnostic ultrasound. 3rd ed. St Louis: Saunders Elsevier, 2015;366.

  • 21.

    Zawie DA, Garvey M. Feline hepatic disease. Vet Clin North Am Small Anim Pract 1984;14:12011230.

  • 22.

    Dimski DS, Taboada J. Feline idiopathic hepatic lipidosis. Vet Clin North Am Small Anim Pract 1995;25:357373.

  • 23.

    Brunt EM, Tiniakos DG. Histopathology of nonalcoholic fatty liver disease. World J Gastroenterol 2010;16:52865296.

  • 24.

    Holdsworth A, Bradley K, Birch S, et al. Elastography of the normal canine liver, spleen and kidneys. Vet Radiol Ultrasound 2014;55:620627.

  • 25.

    Tamura M, Ohta H, Nisa K, et al. Evaluation of liver and spleen stiffness of healthy dogs by use of two-dimensional shear wave elastography. Am J Vet Res 2019;80:378384.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 26.

    Toshima T, Shirabe K, Takeishi K, et al. New method for assessing liver fibrosis based on acoustic radiation force impulse: a special reference to the difference between right and left liver. J Gastroenterol 2011;46:705711.

    • Crossref
    • Search Google Scholar
    • Export Citation

Advertisement