Comparison of shear-wave velocities obtained with shear-wave elastography of various peripheral lymph nodes in healthy Beagles

Yu-rim Kang From the Department of Veterinary Medical Imaging, College of Veterinary Medicine, Konkuk University, Seoul 05029, South Korea.

Search for other papers by Yu-rim Kang in
Current site
Google Scholar
PubMed
Close
 DVM, MS
,
Su-hyeon Lee From the Department of Veterinary Medical Imaging, College of Veterinary Medicine, Konkuk University, Seoul 05029, South Korea.

Search for other papers by Su-hyeon Lee in
Current site
Google Scholar
PubMed
Close
 DVM, MS
,
Im-mee Seo From the Department of Veterinary Medical Imaging, College of Veterinary Medicine, Konkuk University, Seoul 05029, South Korea.

Search for other papers by Im-mee Seo in
Current site
Google Scholar
PubMed
Close
 DVM, MS
,
Jae-un Ko From the Department of Veterinary Medical Imaging, College of Veterinary Medicine, Konkuk University, Seoul 05029, South Korea.

Search for other papers by Jae-un Ko in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
,
Jae-hwan Kim From the Department of Veterinary Medical Imaging, College of Veterinary Medicine, Konkuk University, Seoul 05029, South Korea.

Search for other papers by Jae-hwan Kim in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
, and
Ki-dong Eom From the Department of Veterinary Medical Imaging, College of Veterinary Medicine, Konkuk University, Seoul 05029, South Korea.

Search for other papers by Ki-dong Eom in
Current site
Google Scholar
PubMed
Close
 DVM, PhD

Abstract

OBJECTIVE

To compare shear-wave velocities (SWVs) with shear-wave elastography of various peripheral lymph nodes (LNs).

ANIMALS

11 healthy Beagles.

PROCEDURES

For each dog, bilateral mandibular, medial retropharyngeal, superficial cervical, axillary, superficial inguinal, and popliteal LNs were evaluated with shear-wave elastography in sagittal and transverse scanning planes. Depth of each lymph node was recorded, and intra- and interobserver reliability was determined.

RESULTS

SWVs for all LNs were significantly higher in the sagittal scanning plane, compared with those in the transverse scanning plane. The SWV of the most superficial LN, the mandibular LN, was significantly higher, compared with that for the other LNs, except for the medial retropharyngeal LN. The SWV of the deepest LN, the medial retropharyngeal LN, was as high as that for the mandibular LN. Intra- and interobserver reliability was excellent.

CONCLUSIONS AND CLINICAL RELEVANCE

SWVs for normal peripheral LNs of Beagles may serve as a reference to compare with those for other breeds and diseased LNs. Scanning plane, LN depth, and interfering tissues between the LN and the transducer may affect SWV. Shear-wave elastography may not be operator dependent.

Abstract

OBJECTIVE

To compare shear-wave velocities (SWVs) with shear-wave elastography of various peripheral lymph nodes (LNs).

ANIMALS

11 healthy Beagles.

PROCEDURES

For each dog, bilateral mandibular, medial retropharyngeal, superficial cervical, axillary, superficial inguinal, and popliteal LNs were evaluated with shear-wave elastography in sagittal and transverse scanning planes. Depth of each lymph node was recorded, and intra- and interobserver reliability was determined.

RESULTS

SWVs for all LNs were significantly higher in the sagittal scanning plane, compared with those in the transverse scanning plane. The SWV of the most superficial LN, the mandibular LN, was significantly higher, compared with that for the other LNs, except for the medial retropharyngeal LN. The SWV of the deepest LN, the medial retropharyngeal LN, was as high as that for the mandibular LN. Intra- and interobserver reliability was excellent.

CONCLUSIONS AND CLINICAL RELEVANCE

SWVs for normal peripheral LNs of Beagles may serve as a reference to compare with those for other breeds and diseased LNs. Scanning plane, LN depth, and interfering tissues between the LN and the transducer may affect SWV. Shear-wave elastography may not be operator dependent.

All Time Past Year Past 30 Days
Abstract Views 234 0 0
Full Text Views 528 282 30
PDF Downloads 395 125 21
Advertisement