1. Bueno I, Redig PT, Rendahl AK. External skeletal fixator intramedullary pin tie-in for the repair of tibiotarsal fractures in raptors: 37 cases (1995–2011). J Am Vet Med Assoc 2015;247:1154–1160.
2. Van Wettere AJ, Wallace LJ, Redig PT, et al. Mechanical evaluation of various external skeletal fixator-intramedullary pin tie-in configurations using a tubular plastic bone model. J Avian Med Surg 2009;23:263–276.
3. Van Wettere AJ, Redig PT, Wallace LJ, et al. Mechanical evaluation of external skeletal fixator-intramedullary pin tie-in configurations applied to cadaveral humeri from red-railed hawks (Buteo jamaicensis). J Avian Med Surg 2009;23:277–285.
4. Haas B, Reichler IM, Montavon PM. Use of the tubular external fixator in the treatment of distal radial and ulnar fractures in small dogs and cats: a retrospective clinical study. Vet Comp Orthop Traumatol 2003;16:132–137.
5. Hatt JM, Christen C, Sandmeier P. Clinical application of an external fixator in the repair of bone fractures in 28 birds. Vet Rec 2007;160:188–194.
6. Muller MG, Nafeez JM. Use of the FixEx Tubulaire Type F.E.S.S.A system for tibiotarsal fractures in falcons. Falco 2007;29:25–28.
7. Meyrueis JP, Masselot A, Meyrueis J. Etude mécanique comparative tridimensionelle de fixateurs externes. Rev Chir Orthop Reparatrice Appar Mot 1993;79:402–406.
8. Kerrigan SM, Kapatkin AS, Garcia TC, et al. Torsional and axial compressive properties of tibiotarsal bones of red-tailed hawks (Buteo jamaicensis). Am J Vet Res 2018;79:388–396.
9. Imex Veterinary Inc. ESF acrylic. Available at: www.imexvet.com/products/category/external-skeletal-fixation/acrylxesf-acrylic. Accessed Jan 25, 2020.
10. Keller JC, Lautenschlager EP. Experimental attempts to reduce acrylic cement porosity. Biomater Med Devices Artif Organs 1983;11:221–236.
11. Keller JC, Lautenschlager EP. Porosity reduction and its associated effect on diametral tensile strength of activated acrylic resins. J Prosthet Dent 1985;53:374–379.
12. Toombs JP. Principles of external skeletal fixation using the Kirschner-Ehmer splint. Semin Vet Med Surg (Small Anim) 1991;6:68–74.
13. Palmer RH, Hulse DA, Hyman WA, et al. Principles of bone healing and biomechanics of external skeletal fixation. Vet Clin North Am Small Anim Pract 1992;22:45–68.
14. Bennett RA. Orthopedic surgery. In: Altman RA, Clubb SL, Dorrestein GM, et al, eds. Avian medicine and surgery. Philadelphia: WB Saunders Co, 1997;733–766.
15. Comiskey DP, Macdonald BJ, McCartney WT, et al. The role of interfragmentary strain on the rate of bone healing—a new interpretation and mathematical model. J Biomech 2010;43:2830–2834.
16. Marsell R, Einhorn TA. The biology of fracture healing. Injury 2011;42:551–555.
Advertisement
To compare the torsional mechanical properties of 2 external skeletal fixators (ESFs) placed with 2 intramedullary pin (IP) and transfixation pin (TP) size combinations in a model of raptor tibiotarsal bone fracture.
24 ESF-synthetic tibiotarsal bone model (polyoxymethylene) constructs.
Synthetic bone models were fabricated with an 8-mm (simulated fracture) gap. Four types of ESF-synthetic bone model constructs (6/group) were tested: a FESSA with a 1.6-mm IP and 1.6-mm TPs, a FESSA with a 2.0-mm IP and 1.1-mm TPs, an acrylic connecting bar with a 1.6-mm IP and 1.6-mm TPs, and an acrylic connecting bar with a 2.0-mm IP and 1.1-mm TPs. Models were rotated in torsion (5°/s) to failure or the machine angle limit (80°). Mechanical variables at yield and at failure were determined from load deformation curves. Effects of overall construct type, connecting bar type, and IP and TP size combination on mechanical properties were assessed with mixed-model ANOVAs.
Both FESSA constructs had significantly greater median stiffness and median torque at yield than both acrylic bar constructs; FESSA constructs with a 1.6-mm IP and 1.6-mm TPs had greatest stiffness of all tested constructs and lowest gap strain at yield. No FESSA constructs failed during testing; 7 of 12 acrylic bar constructs failed by fracture of the connecting bar at the interface with a TP.
Although acrylic bar ESFs have been successfully used in avian patients, the FESSA constructs in this study were mechanically superior to acrylic bar constructs, with greatest benefit resulting from use with the larger TP configuration.
Dr. Kerrigan's present address is Vista Veterinary Specialists, Sacramento, CA 95831.
Dr. Robinson's present address is BluePearl Specialty and Emergency Pet Hospital, Seattle, WA 98133.