Radiation exposure of dogs and cats undergoing fluoroscopic procedures and for operators performing those procedures

Rebecca A. Hersh-Boyle 1Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, Davis, CA 95616.

Search for other papers by Rebecca A. Hersh-Boyle in
Current site
Google Scholar
PubMed
Close
 DVM
,
William T. N. Culp 1Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, Davis, CA 95616.

Search for other papers by William T. N. Culp in
Current site
Google Scholar
PubMed
Close
 VMD
,
Dorothy C. Brown 3Martingale Consulting LLC, 2420 Martingale Rd, Media, PA 19063.

Search for other papers by Dorothy C. Brown in
Current site
Google Scholar
PubMed
Close
 MS, DVM
,
Austin C. Luskin 4Department of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104.

Search for other papers by Austin C. Luskin in
Current site
Google Scholar
PubMed
Close
 VMD
,
Amy S. Kapatkin 1Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, Davis, CA 95616.

Search for other papers by Amy S. Kapatkin in
Current site
Google Scholar
PubMed
Close
 DVM
,
Po-Yen Chou 1Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, Davis, CA 95616.

Search for other papers by Po-Yen Chou in
Current site
Google Scholar
PubMed
Close
 DVM
,
Kimberly A. Agnello 4Department of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104.

Search for other papers by Kimberly A. Agnello in
Current site
Google Scholar
PubMed
Close
 DVM
,
Jennifer A. Reetz 4Department of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104.

Search for other papers by Jennifer A. Reetz in
Current site
Google Scholar
PubMed
Close
 DVM
,
Mark A. Oyama 4Department of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104.

Search for other papers by Mark A. Oyama in
Current site
Google Scholar
PubMed
Close
 DVM
,
Lance C. Visser 2Department of Medicine and Epidemiology, School of Veterinary Medicine, University of California-Davis, Davis, CA 95616.

Search for other papers by Lance C. Visser in
Current site
Google Scholar
PubMed
Close
 DVM, MS
,
Carrie A. Palm 2Department of Medicine and Epidemiology, School of Veterinary Medicine, University of California-Davis, Davis, CA 95616.

Search for other papers by Carrie A. Palm in
Current site
Google Scholar
PubMed
Close
 DVM
, and
Dana L. Clarke 4Department of Clinical Sciences and Advanced Medicine, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104.

Search for other papers by Dana L. Clarke in
Current site
Google Scholar
PubMed
Close
 VMD

Abstract

OBJECTIVE

To evaluate radiation exposure of dogs and cats undergoing procedures requiring intraoperative fluoroscopy and for operators performing those procedures.

SAMPLE

360 fluoroscopic procedures performed at 2 academic institutions between 2012 and 2015.

PROCEDURES

Fluoroscopic procedures were classified as vascular, urinary, respiratory, cardiac, gastrointestinal, and orthopedic. Fluoroscopy operators were classified as interventional radiology-trained clinicians, orthopedic surgeons, soft tissue surgeons, internists, and cardiologists. Total radiation exposure in milligrays and total fluoroscopy time in minutes were obtained from dose reports for 4 C-arm units. Kruskal-Wallis equality of populations rank tests and Dunn pairwise comparisons were used to compare differences in time and exposure among procedures and operators.

RESULTS

Fluoroscopy time (median, 35.80 minutes; range, 0.60 to 84.70 minutes) was significantly greater and radiation exposure (median, 137.00 mGy; range, 3.00 to 617.51 mGy) was significantly higher for vascular procedures than for other procedures. Median total radiation exposure was significantly higher for procedures performed by interventional radiology-trained clinicians (16.10 mGy; range, 0.44 to 617.50 mGy), cardiologists (25.82 mGy; range, 0.33 to 287.45 mGy), and internists (25.24 mGy; range, 3.58 to 185.79 mGy).

CONCLUSIONS AND CLINICAL RELEVANCE

Vascular fluoroscopic procedures were associated with significantly longer fluoroscopy time and higher radiation exposure than were other evaluated fluoroscopic procedures. Future studies should focus on quantitative radiation monitoring for patients and operators, importance of operator training, intraoperative safety measures, and protocols for postoperative monitoring of patients.

Abstract

OBJECTIVE

To evaluate radiation exposure of dogs and cats undergoing procedures requiring intraoperative fluoroscopy and for operators performing those procedures.

SAMPLE

360 fluoroscopic procedures performed at 2 academic institutions between 2012 and 2015.

PROCEDURES

Fluoroscopic procedures were classified as vascular, urinary, respiratory, cardiac, gastrointestinal, and orthopedic. Fluoroscopy operators were classified as interventional radiology-trained clinicians, orthopedic surgeons, soft tissue surgeons, internists, and cardiologists. Total radiation exposure in milligrays and total fluoroscopy time in minutes were obtained from dose reports for 4 C-arm units. Kruskal-Wallis equality of populations rank tests and Dunn pairwise comparisons were used to compare differences in time and exposure among procedures and operators.

RESULTS

Fluoroscopy time (median, 35.80 minutes; range, 0.60 to 84.70 minutes) was significantly greater and radiation exposure (median, 137.00 mGy; range, 3.00 to 617.51 mGy) was significantly higher for vascular procedures than for other procedures. Median total radiation exposure was significantly higher for procedures performed by interventional radiology-trained clinicians (16.10 mGy; range, 0.44 to 617.50 mGy), cardiologists (25.82 mGy; range, 0.33 to 287.45 mGy), and internists (25.24 mGy; range, 3.58 to 185.79 mGy).

CONCLUSIONS AND CLINICAL RELEVANCE

Vascular fluoroscopic procedures were associated with significantly longer fluoroscopy time and higher radiation exposure than were other evaluated fluoroscopic procedures. Future studies should focus on quantitative radiation monitoring for patients and operators, importance of operator training, intraoperative safety measures, and protocols for postoperative monitoring of patients.