Repeatability and reproducibility of right ventricular Tei index valves derived from three echocardiographic methods for evaluation of cardiac function in dogs

Tomoya Morita Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido 060-0818, Japan.

Search for other papers by Tomoya Morita in
Current site
Google Scholar
PubMed
Close
 DVM
,
Kensuke Nakamura Veterinary Teaching Hospital, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido 060-0818, Japan.

Search for other papers by Kensuke Nakamura in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
,
Tatsuyuki Osuga Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido 060-0818, Japan.

Search for other papers by Tatsuyuki Osuga in
Current site
Google Scholar
PubMed
Close
 DVM
,
Sue Yee Lim Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido 060-0818, Japan.

Search for other papers by Sue Yee Lim in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
,
Nozomu Yokoyama Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido 060-0818, Japan.

Search for other papers by Nozomu Yokoyama in
Current site
Google Scholar
PubMed
Close
 DVM
,
Keitaro Morishita Veterinary Teaching Hospital, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido 060-0818, Japan.

Search for other papers by Keitaro Morishita in
Current site
Google Scholar
PubMed
Close
 DVM
,
Hiroshi Ohta Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido 060-0818, Japan.

Search for other papers by Hiroshi Ohta in
Current site
Google Scholar
PubMed
Close
 DVM, PhD
, and
Mitsuyoshi Takiguchi Laboratory of Veterinary Internal Medicine, Department of Veterinary Clinical Sciences, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo, Hokkaido 060-0818, Japan.

Search for other papers by Mitsuyoshi Takiguchi in
Current site
Google Scholar
PubMed
Close
 DVM, PhD

Abstract

OBJECTIVE To evaluate repeatability and reproducibility of right ventricular Tei index (RTX) values derived from dual pulsed-wave Doppler, conventional pulsed-wave Doppler, and tissue Doppler echocardiography and to investigate relationships and repeatability among the 3 methods in healthy dogs.

ANIMALS 6 healthy adult Beagles.

PROCEDURE Echocardiography was performed on each dog on different days for 2 weeks (3 times/d) by 2 echocardiographers. Intraobserver within- and between-day and interobserver coefficients of variation (CVs) and intraclass correlation coefficients (ICCs) for RTXs derived from dual pulse-waved Doppler (RTXDPD), conventional pulsed-wave Doppler (RTXPD), and tissue Doppler (RTXTD) methods were determined. Degrees of agreement among RTX values derived from the 3 methods were assessed by modified Bland-Altman analysis.

RESULTS Least squares mean (95% confidence interval) RTXtd was 0.50 (0.46 to 0.54), which was significantly higher than that for RTXDPD (0.27 [0.23 to 0.31]) and RTXPD (0.25 [0.21 to 0.29]). Agreement between RTXDPD and RTXPD was good (bias [mean difference], 0.04 [95% confidence interval, −0.03 to 0.10]). The RTXdpd had high within-day (CV, 6.1; ICC, 0.77) and interobserver (CV, 3.5; ICC, 0.83) repeatability, but between-day repeatability was not high. The RTXtd had high within-day repeatability (CV, 6.0; ICC, 0.80), but between-day and interobserver repeatability were not high. Within-day, between-day, and interobserver repeatability of RTXPD were not high.

CONCLUSIONS AND CLINICAL RELEVANCE RTXdpd measurement was a repeatable and reproducible method of cardiac evaluation in healthy dogs. The RTXTD values were significantly higher than the RTXDPD and RTXPD values; therefore, RTX values derived from different echocardiographic methods should be interpreted with caution.

Abstract

OBJECTIVE To evaluate repeatability and reproducibility of right ventricular Tei index (RTX) values derived from dual pulsed-wave Doppler, conventional pulsed-wave Doppler, and tissue Doppler echocardiography and to investigate relationships and repeatability among the 3 methods in healthy dogs.

ANIMALS 6 healthy adult Beagles.

PROCEDURE Echocardiography was performed on each dog on different days for 2 weeks (3 times/d) by 2 echocardiographers. Intraobserver within- and between-day and interobserver coefficients of variation (CVs) and intraclass correlation coefficients (ICCs) for RTXs derived from dual pulse-waved Doppler (RTXDPD), conventional pulsed-wave Doppler (RTXPD), and tissue Doppler (RTXTD) methods were determined. Degrees of agreement among RTX values derived from the 3 methods were assessed by modified Bland-Altman analysis.

RESULTS Least squares mean (95% confidence interval) RTXtd was 0.50 (0.46 to 0.54), which was significantly higher than that for RTXDPD (0.27 [0.23 to 0.31]) and RTXPD (0.25 [0.21 to 0.29]). Agreement between RTXDPD and RTXPD was good (bias [mean difference], 0.04 [95% confidence interval, −0.03 to 0.10]). The RTXdpd had high within-day (CV, 6.1; ICC, 0.77) and interobserver (CV, 3.5; ICC, 0.83) repeatability, but between-day repeatability was not high. The RTXtd had high within-day repeatability (CV, 6.0; ICC, 0.80), but between-day and interobserver repeatability were not high. Within-day, between-day, and interobserver repeatability of RTXPD were not high.

CONCLUSIONS AND CLINICAL RELEVANCE RTXdpd measurement was a repeatable and reproducible method of cardiac evaluation in healthy dogs. The RTXTD values were significantly higher than the RTXDPD and RTXPD values; therefore, RTX values derived from different echocardiographic methods should be interpreted with caution.

All Time Past Year Past 30 Days
Abstract Views 83 0 0
Full Text Views 4820 1221 79
PDF Downloads 292 114 13
Advertisement