Digital image analysis of rhodanine-stained liver biopsy specimens for calculation of hepatic copper concentrations in dogs

Sharon A. Center Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY, 14853.

Search for other papers by Sharon A. Center in
Current site
Google Scholar
PubMed
Close
 DVM
,
Sean P. McDonough Department of Biomedical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY, 14853.

Search for other papers by Sean P. McDonough in
Current site
Google Scholar
PubMed
Close
 DVM
, and
Lewis Bogdanovic Department of Biomedical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY, 14853.

Search for other papers by Lewis Bogdanovic in
Current site
Google Scholar
PubMed
Close
 DVM

Abstract

Objective—To evaluate the accuracy of digitally scanned rhodanine-stained liver biopsy specimens for determination of hepatic copper concentration and compare results with qualitatively assigned histologic copper scores in dogs.

Sample—353 liver biopsy specimens from dogs.

Procedures—Specimens (n = 139) with quantified copper concentration ranging from 93 to 6,900 μg/g were allocated to group 1 (< 400 μg/g [37]), group 2 (401 to 1,000 μg/g [27]), group 3 (1,001 to 2,000 μg/g [34]), and group 4 (> 2,001 μg/g [41]); stained with rhodanine; and digitally scanned and analyzed with a proprietary positive pixel algorithm. Measured versus calculated copper concentrations were compared, and limits of agreement determined. Influence of nodular remodeling, fibrosis, or parenchymal loss on copper concentration was determined by digitally analyzing selected regions in 17 specimens. After method validation, 214 additional liver specimens underwent digital scanning for copper concentration determination. All sections (n = 353) were then independently scored by 2 naive evaluators with a qualitative scoring schema. Agreement between assigned scores and between assigned scores and tissue copper concentrations was determined.

Results—Linear regression was used to develop a formula for calculating hepatic copper concentration ≥ 400 μg/g from scanned sections. Copper concentrations in unremodeled specimens were significantly higher than in remodeled specimens. Qualitative scores widely overlapped among quantitative copper concentration groups.

Conclusions and Clinical Relevance—Calculated copper concentrations determined by means of digital scanning of rhodanine-stained liver sections were highly correlated with measured values and more accurate than qualitative copper scores, which should improve diagnostic usefulness of hepatic copper concentrations and assessments in sequential biopsy specimens.

Abstract

Objective—To evaluate the accuracy of digitally scanned rhodanine-stained liver biopsy specimens for determination of hepatic copper concentration and compare results with qualitatively assigned histologic copper scores in dogs.

Sample—353 liver biopsy specimens from dogs.

Procedures—Specimens (n = 139) with quantified copper concentration ranging from 93 to 6,900 μg/g were allocated to group 1 (< 400 μg/g [37]), group 2 (401 to 1,000 μg/g [27]), group 3 (1,001 to 2,000 μg/g [34]), and group 4 (> 2,001 μg/g [41]); stained with rhodanine; and digitally scanned and analyzed with a proprietary positive pixel algorithm. Measured versus calculated copper concentrations were compared, and limits of agreement determined. Influence of nodular remodeling, fibrosis, or parenchymal loss on copper concentration was determined by digitally analyzing selected regions in 17 specimens. After method validation, 214 additional liver specimens underwent digital scanning for copper concentration determination. All sections (n = 353) were then independently scored by 2 naive evaluators with a qualitative scoring schema. Agreement between assigned scores and between assigned scores and tissue copper concentrations was determined.

Results—Linear regression was used to develop a formula for calculating hepatic copper concentration ≥ 400 μg/g from scanned sections. Copper concentrations in unremodeled specimens were significantly higher than in remodeled specimens. Qualitative scores widely overlapped among quantitative copper concentration groups.

Conclusions and Clinical Relevance—Calculated copper concentrations determined by means of digital scanning of rhodanine-stained liver sections were highly correlated with measured values and more accurate than qualitative copper scores, which should improve diagnostic usefulness of hepatic copper concentrations and assessments in sequential biopsy specimens.

All Time Past Year Past 30 Days
Abstract Views 165 0 0
Full Text Views 1310 678 53
PDF Downloads 1015 459 31
Advertisement