Comparison of an inertial sensor system with a stationary force plate for evaluation of horses with bilateral forelimb lameness

Kevin G. Keegan Department of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO 65211.

Search for other papers by Kevin G. Keegan in
Current site
Google Scholar
PubMed
Close
 DVM, MS
,
Charles G. MacAllister Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Oklahoma State University, Stillwater, OK 74078.

Search for other papers by Charles G. MacAllister in
Current site
Google Scholar
PubMed
Close
 DVM
,
David A. Wilson Department of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO 65211.

Search for other papers by David A. Wilson in
Current site
Google Scholar
PubMed
Close
 DVM, MS
,
Carl A. Gedon Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Oklahoma State University, Stillwater, OK 74078.

Search for other papers by Carl A. Gedon in
Current site
Google Scholar
PubMed
Close
,
Joanne Kramer Department of Veterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, MO 65211.

Search for other papers by Joanne Kramer in
Current site
Google Scholar
PubMed
Close
 DVM
,
Yoshiharu Yonezawa Department of Health Science, Faculty of Applied Information Science, Hiroshima Institute of Technology, 2-1-1 Miyake, Saeki-ku, Hiroshima 731-5193, Japan.

Search for other papers by Yoshiharu Yonezawa in
Current site
Google Scholar
PubMed
Close
 PhD
,
Hiromitchi Maki Department of Health Science, Faculty of Applied Information Science, Hiroshima Institute of Technology, 2-1-1 Miyake, Saeki-ku, Hiroshima 731-5193, Japan.

Search for other papers by Hiromitchi Maki in
Current site
Google Scholar
PubMed
Close
 PhD
, and
P. Frank Pai Department of Mechanical and Aerospace Engineering, College of Engineering, University of Missouri, Columbia, MO 65211.

Search for other papers by P. Frank Pai in
Current site
Google Scholar
PubMed
Close
 PhD

Abstract

Objective—To assess the analytic sensitivity of an inertial sensor system for detection of the more severely affected forelimb in horses with bilateral lameness.

Animals—18 adult horses with forelimb lameness.

Procedures—Horses were fitted with inertial sensors and evaluated for lameness with a stationary force plate as they were trotted in a straight line. Inertial sensor-derived measurements for vertical head movement asymmetry (HMA) and vector sum (VS) of maximum and minimum head height differences between right and left halves of the stride were used to predict differences in mean peak vertical force (PVF) as a percentage of body weight between the right and left forelimbs. Repeatability was compared by calculation of the intraclass correlation coefficient (ICC) for each variable. Correct classification percentages for the lamer forelimb were determined by use of a stationary force plate as the standard.

Results—SEs of the prediction of difference in PVF between the right and left forelimbs from HMA and VS were 6.1% and 5.2%, respectively. Head movement asymmetry (ICC, 0.72) was less repeatable than PVF (ICC, 0.86) and VS (ICC, 0.84). Associations were positive and significant between HMA (R2 = 0.73) and VS (R2 = 0.81) and the difference in PVF between the right and left forelimbs. Correct classification percentages for HMA and VS for detecting the lamer forelimb were 83.3% and 77.8%, respectively.

Conclusions and Clinical Relevance—Results suggested that an inertial sensor system to measure vertical asymmetry (HMA and VS) due to forelimb lameness in horses trotting in a straight line has adequate analytic sensitivity for clinical use. Additional studies are required to assess specificity of the system.

Abstract

Objective—To assess the analytic sensitivity of an inertial sensor system for detection of the more severely affected forelimb in horses with bilateral lameness.

Animals—18 adult horses with forelimb lameness.

Procedures—Horses were fitted with inertial sensors and evaluated for lameness with a stationary force plate as they were trotted in a straight line. Inertial sensor-derived measurements for vertical head movement asymmetry (HMA) and vector sum (VS) of maximum and minimum head height differences between right and left halves of the stride were used to predict differences in mean peak vertical force (PVF) as a percentage of body weight between the right and left forelimbs. Repeatability was compared by calculation of the intraclass correlation coefficient (ICC) for each variable. Correct classification percentages for the lamer forelimb were determined by use of a stationary force plate as the standard.

Results—SEs of the prediction of difference in PVF between the right and left forelimbs from HMA and VS were 6.1% and 5.2%, respectively. Head movement asymmetry (ICC, 0.72) was less repeatable than PVF (ICC, 0.86) and VS (ICC, 0.84). Associations were positive and significant between HMA (R2 = 0.73) and VS (R2 = 0.81) and the difference in PVF between the right and left forelimbs. Correct classification percentages for HMA and VS for detecting the lamer forelimb were 83.3% and 77.8%, respectively.

Conclusions and Clinical Relevance—Results suggested that an inertial sensor system to measure vertical asymmetry (HMA and VS) due to forelimb lameness in horses trotting in a straight line has adequate analytic sensitivity for clinical use. Additional studies are required to assess specificity of the system.

All Time Past Year Past 30 Days
Abstract Views 255 0 0
Full Text Views 1449 641 60
PDF Downloads 825 280 15
Advertisement