Comparison of continuous arterial pressure waveform analysis with the lithium dilution technique to monitor cardiac output in conscious dogs with systemic inflammatory response syndrome

Amanda L. Duffy Small Animal Emergency and Critical Care Service, Department of Clinical Sciences, College of Veterinary Medicine & Biomedical Sciences, Colorado State University, Fort Collins, CO 80528.

Search for other papers by Amanda L. Duffy in
Current site
Google Scholar
PubMed
Close
 DVM
,
Amy L. Butler Small Animal Emergency and Critical Care Service, Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, OH 43210.

Search for other papers by Amy L. Butler in
Current site
Google Scholar
PubMed
Close
 DVM, MS
,
Steven V. Radecki Biostatistician, 150 N County Rd 3, Fort Collins, CO 80524.

Search for other papers by Steven V. Radecki in
Current site
Google Scholar
PubMed
Close
 PhD, MS
, and
Vicki L. Campbell Small Animal Emergency and Critical Care Service, Department of Clinical Sciences, College of Veterinary Medicine & Biomedical Sciences, Colorado State University, Fort Collins, CO 80528.

Search for other papers by Vicki L. Campbell in
Current site
Google Scholar
PubMed
Close
 DVM

Abstract

Objective—To assess the agreement between cardiac output (CO) measured by use of arterial pressure waveform analysis (PulseCO) and lithium dilution (LiDCO) in conscious dogs with systemic inflammatory response syndrome (SIRS).

Animals—14 dogs with naturally occurring SIRS.

Procedures—Pulse power analysis was performed on critically ill patients with a PulseCO monitor. All measurements were obtained with an indwelling arterial line and in accordance with the manufacturer's instructions. Intermittent measurements of CO were obtained with the LiDCO method to validate the PulseCO measurements at initial calibration (baseline; time 0) and at 4, 8, 16, and 24 hours. The 2 methods for measuring CO were compared by use of Bland-Altman analysis. An error rate for the limits of agreement between the 2 methods of < 30% was defined as being acceptable.

Results—Bland-Altman analysis did not indicate good agreement between measurements obtained by use of the PulseCO and LiDCO methods, despite no significant change in cardiac index (CI) over time as measured with the LiDCO method. The percentage error for the overall difference in CI values between the PulseCO and LiDCO measurements was 122%, which indicated that the PulseCO method was not an acceptable means of CO measurement when compared with the LiDCO method for this patient population.

Conclusions and Clinical Relevance—Agreement between the PulseCO and LiDCO methods for measurement of CO was not acceptable at 4- and 8-hour intervals after calibration in conscious dogs with naturally occurring SIRS.

Abstract

Objective—To assess the agreement between cardiac output (CO) measured by use of arterial pressure waveform analysis (PulseCO) and lithium dilution (LiDCO) in conscious dogs with systemic inflammatory response syndrome (SIRS).

Animals—14 dogs with naturally occurring SIRS.

Procedures—Pulse power analysis was performed on critically ill patients with a PulseCO monitor. All measurements were obtained with an indwelling arterial line and in accordance with the manufacturer's instructions. Intermittent measurements of CO were obtained with the LiDCO method to validate the PulseCO measurements at initial calibration (baseline; time 0) and at 4, 8, 16, and 24 hours. The 2 methods for measuring CO were compared by use of Bland-Altman analysis. An error rate for the limits of agreement between the 2 methods of < 30% was defined as being acceptable.

Results—Bland-Altman analysis did not indicate good agreement between measurements obtained by use of the PulseCO and LiDCO methods, despite no significant change in cardiac index (CI) over time as measured with the LiDCO method. The percentage error for the overall difference in CI values between the PulseCO and LiDCO measurements was 122%, which indicated that the PulseCO method was not an acceptable means of CO measurement when compared with the LiDCO method for this patient population.

Conclusions and Clinical Relevance—Agreement between the PulseCO and LiDCO methods for measurement of CO was not acceptable at 4- and 8-hour intervals after calibration in conscious dogs with naturally occurring SIRS.

Contributor Notes

Supported by a grant from the Colorado State University College Research Council.

Address correspondence to Dr. Duffy (aduffy@colostate.edu).
  • 1.

    Oestern HJ, Trentz O, Hempelmann G, et al. Cardiorespiratory and metabolic patterns in multiple trauma patients. Resuscitation 1979;7:169183.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 2.

    Shoemaker WC, Carey JS, Yao ST, et al. Hemodynamic monitoring for physiologic evaluation, diagnosis, and therapy of acute hemopericardial tamponade from penetrating wounds. J Trauma 1973;13:3644.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 3.

    Egan JR, Festa M, Cole AD, et al. Clinical assessment of cardiac performance in infants and children following cardiac surgery. Intensive Care Med 2005;31:568573.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 4.

    Tibby SM, Hatherill M, Marsh MJ, et al. Clinicians' abilities to estimate cardiac index in ventilated children and infants. Arch Dis Child 1997;77:516518.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 5.

    Butler AL, Campbell VL, Wagner AE, et al. Lithium dilution cardiac output and oxygen delivery in conscious dogs with systemic inflammatory response syndrome. J Vet Emerg Crit Care 2008;18:246257.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 6.

    Eisenberg PR, Jaffe AS, Schuster DP. Clinical evaluation compared to pulmonary artery catheterization in the hemodynamic assessment of critically ill patients. Crit Care Med 1984;12:549553.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 7.

    Vincent JL, De Backer D. Cardiac output measurement: is least invasive always the best? Crit Care Med 2002;30:23802382.

  • 8.

    Miyake Y, Wagner AE, Hellyer PW. Evaluation of hemodynamic measurements, including lithium dilution cardiac output, in anesthetized dogs undergoing ovariohysterectomy. J Am Vet Med Assoc 2005;227:14191423.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 9.

    Beaulieu KE, Kerr CL, McDonell WN. Evaluation of a lithium dilution cardiac output technique as a method for measurement of cardiac output in anesthetized cats. Am J Vet Res 2005;66:16391645.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 10.

    Merjavy JP, Hahn JW, Barner HB. Comparison of thermodilution cardiac output and electromagnetic flowmeter. Surg Forum 1974;25:145147.

  • 11.

    Corley KT, Donaldson LL, Durando MM, et al. Cardiac output technologies with special reference to the horse. J Vet Intern Med 2003;17:262272.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 12.

    Gunkel CI, Valverde A, Morey TE, et al. Comparison of non-invasive cardiac output measurement by partial carbon dioxide rebreathing with the lithium dilution method in anesthetized dogs. J Vet Emerg Crit Care 2004;14:187195.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 13.

    Linton RA, Young LE, Marlin DJ, et al. Cardiac output measured by lithium dilution, thermodilution, and transesophageal Doppler echocardiography in anesthetized horses. Am J Vet Res 2000;61:731737.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 14.

    Hamilton TT, Huber LM, Jessen ME. PulseCO: a less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery. Ann Thorac Surg 2002;74:S1408S1412.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 15.

    Connors AF Jr, Speroff T, Dawson NV, et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 1996;276:889897.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 16.

    Kurita T, Morita K, Kato S, et al. Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output. Br J Anaesth 1997;79:770775.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 17.

    Mason DJ, O'Grady M, Woods JP, et al. Assessment of lithium dilution cardiac output as a technique for measurement of cardiac output in dogs (Erratum published in Am J Vet Res 2001;62:1611). Am J Vet Res 2001;62:12551261.

    • Search Google Scholar
    • Export Citation
  • 18.

    Linton NW, Linton RA. Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb. Br J Anaesth 2001;86:486496.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 19.

    Cecconi M, Fawcett J, Grounds RM, et al. A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients. BMC Anesthesiol 2008;8:3.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 20.

    Jonas M, Hett D, Morgan J. Real time, continuous monitoring of cardiac output and oxygen delivery. Int J Intensive Care 2002;9:3342.

  • 21.

    Chen HC, Sinclair MD, Dyson DH, et al. Comparison of arterial pressure waveform analysis with the lithium dilution technique to monitor cardiac output in anesthetized dogs. Am J Vet Res 2005;66:14301436.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 22.

    Cooper ES, Muir WW. Continuous cardiac output monitoring via arterial pressure waveform analysis following severe hemorrhagic shock in dogs. Crit Care Med 2007;35:17241729.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 23.

    Brady CA, Otto CM. Systemic inflammatory response syndrome, sepsis, and multiple organ dysfunction. Vet Clin North Am Small Anim Pract 2001;31:11471162.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 24.

    Jonas MM, Tanser SJ. Lithium dilution measurement of cardiac output and arterial pulse waveform analysis: an indicator dilution calibrated beat-by-beat system for continuous estimation of cardiac output. Curr Opin Crit Care 2002;8:257261.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 25.

    Mason DJ, O'Grady M, Woods JP, et al. Comparison of a central and a peripheral (cephalic vein) injection site for the measurement of cardiac output using the lithium-dilution cardiac output technique in anesthetized dogs. Can J Vet Res 2002;66:207210.

    • Search Google Scholar
    • Export Citation
  • 26.

    Rhodes A, Sunderland R. Arterial pulse power analysis: the LiDCOplus system. In: Pinsky MR, Payen D, eds. Functional hemodynamic monitoring update in intensive care and emergency medicine. Berlin: Springer-Verlag Inc, 2005;183192.

    • Search Google Scholar
    • Export Citation
  • 27.

    LiDCO plus hemodynamic monitor user's manual: version 2.0. London: LiDCO Plus Plc, 2003.

  • 28.

    Hand MS, Thatcher CD, Remillard RL, et al. Appendix D. In: Hand MS, Thatcher CD, Remillard RL, eds. Small animal clinical nutrition. 4th ed. Marceline, Mo: Walsworth Publishing Co, 2000;10081011.

    • Search Google Scholar
    • Export Citation
  • 29.

    Harbrecht BG. Therapeutic use of nitric oxide scavengers in shock and sepsis. Curr Pharm Des 2006;12:35433549.

  • 30.

    Trepels T, Zeiher AM, Fichtlscherer S. The endothelium and inflammation. Endothelium 2006;13:423429.

  • 31.

    Haskins S, Pascoe PJ, Ilkiw JE, et al. Reference cardiopulmonary values in normal dogs. Comp Med 2005;55:156161.

  • 32.

    Pittman J, Bar-Yosef S, SumPing J, et al. Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement. Crit Care Med 2005;33:20152021.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 33.

    Yamashita K, Nishiyama T, Yokoyama T, et al. Effects of vasodilation on cardiac output measured by PulseCO. J Clin Monit Comput 2007;21:335339.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 34.

    Yamashita K, Nishiyama T, Yokoyama T, et al. Cardiac output by PulseCO is not interchangeable with thermodilution in patients undergoing OPCAB. Can J Anaesth 2005;52:530534.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 35.

    Heller LB, Fisher M, Pfanzelter N, et al. Continuous intra-operative cardiac output determination with arterial pulse wave analysis (PulseCO) is valid and precise. Anesth Analg 2002;93:SCA1SCA112.

    • Search Google Scholar
    • Export Citation
  • 36.

    Stetz CW, Miller RG, Kelly GE, et al. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis 1982;126:10011004.

    • Search Google Scholar
    • Export Citation
  • 37.

    Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999;15:8591.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 38.

    Costa MG, Della Rocca G, Chiarandini P, et al. Continuous and intermittent cardiac output measurement in hyperdynamic conditions: pulmonary artery catheter vs. lithium dilution technique. Intensive Care Med 2008;34:257263.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 39.

    Nichols WW, O-Rourke MF. Vascular impedance. In: Nichols WW, O'Rourke MF, eds. McDonald's blood flow in arteries. Philadelphia: Lea & Febiger, 1990;243292.

    • Search Google Scholar
    • Export Citation
  • 40.

    Hatfield CL, McDonell WN, Lemke KA, et al. Pharmacokinetics and toxic effects of lithium chloride after intravenous administration in conscious horses. Am J Vet Res 2001;62:13871392.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 41.

    Rosenthal RC, Koritz GD. Pharmacokinetics of lithium in beagles. J Vet Pharmacol Ther 1989;12:330333.

  • 42.

    Rosenthal RC, Koritz GD, Davis LE. Pharmacokinetics of lithium in the dog. J Vet Pharmacol Ther 1986;9:8187.

  • 43.

    Freeman MP, Freeman SA. Lithium: clinical considerations in internal medicine. Am J Med 2006;119:478481.

  • 44.

    Davies NL. Lithium toxicity in two dogs. J S Afr Vet Assoc 1991;62:140142.

  • 45.

    Mason DJ, O'Grady M, Woods JP, et al. Effect of background serum lithium concentrations on the accuracy of lithium dilution cardiac output determination in dogs. Am J Vet Res 2002;63:10481052.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 46.

    English JB, Hodges MR, Sentker C, et al. Comparison of aortic pulse-wave contour analysis and thermodilution methods of measuring cardiac output during anesthesia in the dog. Anesthesiology 1980;52:5661.

    • Crossref
    • Search Google Scholar
    • Export Citation
  • 47.

    Missant C, Rex S, Wouters PF. Accuracy of cardiac output measurements with pulse contour analysis (PulseCo) and Doppler echocardiography during off-pump coronary bypass grafting. Eur J Anesth 2008;25:243248.

    • Crossref
    • Search Google Scholar
    • Export Citation

Advertisement